113 resultados para TRANSIENT
Resumo:
A mechanistic study of the H-2-assisted Selective Catalytic Reduction (SCR) of NOx with octane as reductant over a Ag/Al2O3 catalyst was carried out using a modified DRIFTS cell coupled to a mass spectrometer Using fast transient cycling switching of H-2 with a time resolution of a few seconds It was possible to differentiate potential reaction intermediates from other moieties that are clearly spectator species Using such a periodic operation mode effects were uncovered that are normally hidden in conventional transient studies which typically consist of a single transient In experiments based on a single transient addition of H-2 to or removal of H-2 from the SCR feed it was found that the changes in the concentrations of gaseous species (products and reactants) were not matched by changes at comparable timescales of the concentration of surface species observed by IR This observation indicates that the majority of sur face species observed by DRIFTS under steady-state reaction conditions are spectators In contrast under fast cycling experimental conditions It was found that a surface isocyanate species had a temporal response that matched that of N-15(2) This suggests that some of the isocyanate species observed by infrared spectroscopy could be important intermediates in the hydrogen-assisted SCR reaction although it is emphasised that this may be dependent on the way in which the infrared spectra are obtained It is concluded that the use of fast transient cycling switching techniques may provide useful mechanistic information under certain circumstances.
Resumo:
Studies by laser flash photolysis, transient Raman spectroscopy, and Raman and UV-vis spectroelectrochemistry are described in which the techniques have been used in parallel to compare the lowest energy charge-transfer excited states of Cu (1) complexes ([Cu(L)2]+ and [ (PPh3)2Cu(L)]+ [L = 2,2'-biquinoline (BIQ) or 6,7-dihydro-5,8-dimethyldibenzo[b,j] [1,10]-phenanthroline (DMCH)) with the species produced by electrochemical reduction in the same group of complexes. Transient resonance Raman spectra for the metal-to-ligand charge-transfer (MLCT) states of [Cu(DMCH)2]+ (1), [Cu(BIQ)2]+ (2), [Cu(DMCH)(PPh3)2]+ (3), and [Cu(BIQ)(PPh3)2]+ (4) are compared with the resonance Raman spectra of the same group of complexes following one-electron electrochemical reduction of the DMCH and BIQ ligands. The UV-vis and resonance Raman evidence suggests that the electrochemical reduction of the [Cu(I)L2]+ species proceeds according to the sequence [LCu(I)L]+ -->e- [LCu0L] -->e- [L.-Cu(I)L.-]-. Several features assignable to modes of the electrochemically generated DMCH.-and BIQ'- radical anions exhibit a close correspondence in both frequency and relative intensity with counterparts in the spectra of the MLCT states of 1 and 2. A notable exception is a band near 1590 cm-1 in the spectra of the electrochemically reduced species which occurs some 15 cm-1 lower in the corresponding spectra of the excited-state species. It is suggested that the shift may reflect the change in oxidation state of the metal center from Cu(I) to Cu(II) which occurs as a result of charge-transfer excitation.
Resumo:
Transient outward rectifying conductances or A-like conductances in sympathetic preganglionic neurons (SPN) are prolonged, lasting for hundreds of milliseconds to seconds and are thought to play a key role in the regulation of SPN firing frequency. Here, a multidisciplinary electrophysiological, pharmacological and molecular single-cell rt-PCR approach was used to investigate the kinetics, pharmacological profile and putative K + channel subunits underlying the transient outward rectifying conductance expressed in SPN. SPN expressed a 4-aminopyridine (4-AP) sensitive transient outward rectification with significantly longer decay kinetics than reported for many other central neurons. The conductance and corresponding current in voltage-clamp conditions was also sensitive to the Kv4.2 and Kv4.3 blocker phrixotoxin-2 (1-10 µM) and the blocker of rapidly inactivating Kv channels, pandinotoxin-Ka (50 nM). The conductance and corresponding current was only weakly sensitive to the Kv1 channel blocker tityustoxin-Ka and insensitive to dendrotoxin I (200 nM) and the Kv3.4 channel blocker BDS-II (1 µM). Single-cell RT-PCR revealed mRNA expression for the a-subunits Kv4.1 and Kv4.3 in the majority and Kv1.5 in less than half of SPN. mRNA for accessory ß-subunits was detected for Kvß2 in all SPN with differential expression of mRNA for KChIP1, Kvß1 and Kvß3 and the peptidase homologue DPP6. These data together suggest that the transient outwardly rectifying conductance in SPN is mediated by members of the Kv4 subfamily (Kv4.1 and Kv4.3) in association with the ß-subunit Kvß2. Differential expression of the accessory ß subunits, which may act to modulate channel density and kinetics in SPN, may underlie the prolonged and variable time-course of this conductance in these neurons. © 2011 IBRO.
Resumo:
One important mechanism of membrane ion channels regulation involves their non-functional isoforms generated by alternative splicing. However, knowledge of such isoforms for the members of transient receptor potential (TRP) superfamily of ion channels remains quite limited. This study focuses on TRPM member, TRPM8, which functions as a cold receptor in sensory neurons, but is also expressed in tissues not exposed to ambient temperatures, as well as in cancer tissues. We report the cloning from prostate cancer cells of new short-splice variants of TRPM8, termed short TRPM8a (sM8a) and short TRPM8ß (sM8ß). Our results show that both variants are in a closed configuration with the C-terminal tail of the full-size TRPM8 chan-nel, resulting in stabilization of its closed state and thus reducing both its cold sensitivity and its activity. Our findings, therefore, uncover a new mode of the regulation of TRPM8 channel by its splice variants.
Resumo:
Transient absorption spectroscopy (TAS) has been used to study the interfacial electron-transfer reaction between photogenerated electrons in nanocrystalline titanium dioxide (TiO2) films and molecular oxygen. TiO2 films from three different starting materials (TiO2 anatase colloidal paste and commercial anatase/rutile powders Degussa TiO2 P25 and VP TiO2 P90) have been investigated in the presence of ethanol as a hole scavenger. Separate investigations on the photocatalytic oxygen consumption by the films have also been performed with an oxygen membrane polarographic detector. Results show that a correlation exists between the electron dynamics of oxygen consumption observed by TAS and the rate of oxygen consumption through the photocatalytic process. The highest activity and the fastest oxygen reduction dynamics were observed with films fabricated from anatase TiO2 colloidal paste. The use of TAS as a tool for the prediction of the photocatalytic activities of the materials is discussed. TAS studies indicate that the rate of reduction of molecular oxygen is limited by interfacial electron-transfer kinetics rather than by the electron trapping/detrapping dynamics within the TiO2 particles.
Resumo:
We report what is to our knowledge the first demonstration of a transient x-ray laser pumped by a 350-fs pulse in a traveling-wave irradiation geometry. For a 500-fs pump pulse the traveling-wave irradiation was found to have a strong effect on enhancing the Ni-like silver 4d-4p lasing emission at 13.9 nm. The signal enhancement was significantly less when the pulse duration was lengthened to 1.7 ps. The experimental observations are well reproduced by a simple model when the duration of gain is taken of the order of 15-20 ps. For the 500-fs pulse a gain coefficient of 14.5 cm(-1) was measured for plasma lengths up to 7 mm. Refraction of the amplified photons is believed to be the main cause of the limitation of the effective amplification length. (C) 2000 Optical Society of America.
Resumo:
The collisionally excited transient inversion scheme is shown to produce exceptionally high gain coefficients and gain-length products. Data are presented for the Ne-Like titanium and germanium and Ni-like silver X-ray lasers (XRL's) pumped using a combination of nanosecond and picosecond duration laser pulses. This method leads to a dramatic reduction of the required pump energy and makes down-sizing of XRL's possible, an important prerequisite if they are to become commonly used tools in the Long-term.
Resumo:
A similar to 3 ps travelling wave chirped pulse amplified pulse at 6 x 10(14) W cm(-2) superimposed on similar to 300 ps background pulses is shown to be an efficient method to pump transient collisional excitation X-ray lasers in both Ni-like and Ne-like ions. Measurements of X-ray laser output as a function of plasma length are fitted with results of an amplified spontaneous emission model of the laser output taking account of travelling wave pumping effects. A small signal gain coefficient similar to 42 cm(-1) and a effective gain length product of similar to 18 are measured for the Ni-like Sn laser at 120 Angstrom. Simulations from a hydrodynamic and atomic physics code (EHYBRID) coupled to a ray trace code show that a spatially averaged small signal gain similar to 65 cm(-1) can be obtained in Ne-like Ge provided the optimum pumping pulse arrangement is used. (C) 1999 Elsevier Science B.V. All rights reserved.
Resumo:
Saturation of a low pump energy x-ray laser utilizing a transient inversion mechanism on the 3p-3s transition at 32.63 nm in Ne-like Ti has been demonstrated. A close to saturation amplification was simultaneously achieved for the 3d-3p, J=1-->1 transition at 30.15 nm. Small signal effective transient gain coefficients of g similar to 46 and similar to 35 cm(-1) and gain-length products of 16.7 and 16.9 for these lines were obtained. Experiments demonstrate that it is possible to achieve saturated laser action in a transient regime with Ne-like Ti for a pump energy as low as similar to 5 J.
Resumo:
The transient-excitation pumping scheme, in which a picosecond duration pulse rapidly heats the plasma preformed by a low-intensity nanosecond pulse, was used to pump the Ne-like germanium, J = 0-1 transition at 19.6 nm. A small-signal gain coefficient of 30 cm(-1) was measured for targets less than or equal to 5 mm long. (C) 1998 Optical Society of America.