74 resultados para Surgical flap grafts
Resumo:
This study was designed to carry out the characterization of stem cells within the adventitia and to elucidate their functional role in the pathogenesis of vein graft atherosclerosis.
Resumo:
The power output from a wave energy converter is typically predicted using experimental and/or numerical modelling techniques. In order to yield meaningful results the relevant characteristics of the device, together with those of the wave climate must be modelled with sufficient accuracy.
The wave climate is commonly described using a scatter table of sea states defined according to parameters related to wave height and period. These sea states are traditionally modelled with the spectral distribution of energy defined according to some empirical formulation. Since the response of most wave energy converters vary at different frequencies of excitation, their performance in a particular sea state may be expected to depend on the choice of spectral shape employed rather than simply the spectral parameters. Estimates of energy production may therefore be affected if the spectral distribution of wave energy at the deployment site is not well modelled. Furthermore, validation of the model may be affected by differences between the observed full scale spectral energy distribution and the spectrum used to model it.
This paper investigates the sensitivity of the performance of a bottom hinged flap type wave energy converter to the spectral energy distribution of the incident waves. This is investigated experimentally using a 1:20 scale model of Aquamarine Power’s Oyster wave energy converter, a bottom hinged flap type device situated at the European Marine Energy Centre (EMEC) in approximately 13m water depth. The performance of the model is tested in sea states defined according to the same wave height and period parameters but adhering to different spectral energy distributions.
The results of these tests show that power capture is reduced with increasing spectral bandwidth. This result is explored with consideration of the spectral response of the device in irregular wave conditions. The implications of this result are discussed in the context of validation of the model against particular prototype data sets and estimation of annual energy production.
Resumo:
Bottom hinged Oscillating Wave Surge Converters (OWSCs) are efficient devices for extracting power from ocean waves. There is limited knowledge about wave slamming on such devices. This paper deals with numerical studies of wave slamming on an oscillating flap to investigate the mechanism of slamming events. In our model, the Navier–Stokes equations are discretized using the Finite Volume method with the Volume of Fluid (VOF) approach for interface capturing. Waves are generated by a flaptype wave maker in the numerical wave tank, and the dynamic mesh method is applied to model the motion of the oscillating flap. Basic mesh and time step refinement studies are performed. The flow characteristics in a slamming event are analysed based on numerical results. Various simulations with different flap densities, water depths and wave amplitudes are performed for a better understanding of the slamming.
Resumo:
Introduction: Immediate reconstruction following mastectomy for breast cancer has been shown to be oncologically safe and associated with improved psychosocial outcomes for patients. Bostwick described a technique for one-stage implant based reconstruction, combining skin-sparing mastectomy with concurrent reduction of the skin envelope. This report reviews the experience of a single centre using skin-reducing mastectomy and one-stage implant reconstruction in both early stage breast cancer and risk-reducing mastectomy, with specific reference to frequency of complications, implant loss and oncological outcomes.
Methods and results: A retrospective review was undertaken to identify women who had undergone skin-reducing mastectomy and one-stage implant reconstruction using a de-epithelialised dermal flap, between October 2008 and October 2012. One hundred and four consecutive mastectomies, with reconstruction, were performed by two surgeons on 64 patients. No complications were seen in 43.8% of patients. At three months, four implants were lost (3.8% of breast reconstructions, 6.3% of patients), due to either peri-implant infection or mastectomy skin flap necrosis. One patient required unplanned return to theatre for evacuation of a haematoma. Minor mastectomy skin flap necrosis was seen in 10 breasts (9.6% of reconstructed breasts) and superficial wound infection in 8 breasts (7.7% of reconstructed breasts). All of these complications were managed conservatively and none required operative intervention. At a median follow up of 35 months (4-53 months) there had been one episode of ipsilateral axillary nodal recurrence.
Conclusion: One-stage implant reconstruction using a myo-dermal flap technique following skin-reducing mastectomy is safe and should be considered in selected patients. Most complications are minor and will resolve with conservative management. Major complications such as implant failure or immediate reoperation, were relatively uncommon (6.3% patients, 3.8% of reconstructed breasts). Early follow-up suggests that oncological outcomes are satisfactory, but longer follow-up is required to substantiate this. (C) 2013 British Association of Plastic, Reconstructive and Aesthetic Surgeons. Published by Elsevier Ltd. All rights reserved.
Resumo:
The incidence of breast cancer in women with implants is increasing and will continue to do so for the foreseeable future due to the marked increase in breast implant insertion in recent years. Undoubtedly many of these women will wish to know whether the presence of implants worsens the prognosis of their breast cancer. Furthermore, the clinical management of such patients may be difficult, as aesthetic results are likely to be a major concern for women who have already undergone cosmetic surgery to the breast. There is no consensus on surgical approach to this scenario. This article reviews the literature on the prognosis of breast cancer patients with a history of augmentation mammoplasty and examines the available data regarding their surgical treatment. (c) 2007 Published by Elsevier Ltd on behalf of British Association of Plastic, Reconstructive and Aesthetic Surgeons.
Resumo:
Large loads result in expensive foundations which are a substantial proportion of the capital cost of flap-type Wave Energy Converters (WECs). Devices such as Oyster 800, currently deployed at the European Marine Energy Centre (EMEC), comprise a single flap for the full width of the machine. Splitting a flap-type device into smaller vertical flap modules, to make a ‘modular-flap’, might reduce the total foundation loads, whilst still providing acceptable performance in terms of energy conversion.
This paper investigates the foundation loads of an undamped modular-flap device, comparing them to those for a rigid flap of an equivalent width. Physical modelling in a wave tank is used, with loads recorded using a six degree of freedom (DoF) load cell. Both fatigue and extreme loading analysis was conducted. The rotations of the flaps were also recorded, using a motion-tracking system.
Resumo:
Aim (1)
A pilot study to determine the accuracy of interpretation of whole slide digital images in a broad range of general histopathology cases of graded complexity. (2) To survey the participating histopathologists with regard to acceptability of digital pathology.
Materials and methods
Glass slides of 100 biopsies and minor resections were digitally scanned in their entirety, producing digital slides. These cases had been diagnosed by light microscopy at least 1 year previously and were subsequently reassessed by the original reporting pathologist (who was blinded to their original diagnosis) using digital pathology. The digital pathology-based diagnosis was compared with the original glass slide diagnosis and classified as concordant, slightly discordant (without clinical consequence) or discordant. The participants were surveyed at the end of the study.
Results
There was concordance between the original light microscopy diagnosis and digital pathology-based diagnosis in 95 of the 100 cases while the remaining 5 cases showed only slight discordance (with no clinical consequence). None of the cases were categorised as discordant. Participants had mixed experiences using digital pathology technology.
Conclusions
In the broad range of cases we examined, digital pathology is a safe and viable method of making a primary histopathological diagnosis.
Resumo:
Title Evaluation of Video Presentation to Deliver Surgical Anatomy Teaching
Authors Walsh I.K., Boohan M., Dorman A.
Objectives To evaluate the efficacy of newly introduced video presentation to deliver Surgical Anatomy teaching to undergraduate medical students.
Design and Setting Qualitative and quantitative study using questionnaires and focus groups, employing students undertaking the perioperative medicine module of the phase 4 undergraduate medical curriculum at Queen’s University Belfast.
Outcome Measures To determine:
(1) if video presentation is effective in delivering surgical anatomy teaching,
(2) student’s learning preferences regarding this teaching method.
Results The questionnaire response rate was 89% (216 of 244 students; female: male ratio 1.25) and 42 students participated in 6 focus groups. Mean questionnaire responses indicated a favourable opinion on quality assurance items, with a mixed response to video presentation as a learning method. 71% of students preferred to receive a lecture in person, rather than via video presentation. There were no statistically significant differences between genders regarding learning preferences in general and regarding video versus live presentation in particular. Exploratory factor analysis demonstrated that favourable responses to video presentation were strongly associated with perceived audiovisual quality and learning preferences (Cronbach’s alpha coefficient 0.77), with 72% of students considering video presentation worthwhile. Positive perception of overall quality was strongly associated with learning preferences as well as more generic quality assurance issues (80% students; alpha coefficient 0.83).
The results were supported by triangulation of the above quantitative data with qualitative data generated by the focus groups. Students further articulated the view that video presentation may be more appropriate and effective in a mixed method setting.
Reference Basu Roy R, McMahon GT. Video-based cases disrupt deep critical thinking in problem-based learning. Med Educ 2012 Apr;46(4):426-435.
Resumo:
Title Evaluation of Multidisciplinary Delivery of Surgical Anatomy Teaching
Authors Walsh I.K., Taylor S.J., Dorman A, Boohan M.
Objectives To evaluate the efficacy of newly introduced multidisciplinary methods to deliver Surgical Anatomy teaching to undergraduate medical students.
Design and Setting Qualitative and quantitative study using questionnaires and focus groups, employing students of the perioperative and emergency medicine (POEM) module of the phase 4 undergraduate medical curriculum at Queen’s University Belfast.
Outcome Measures To determine:
(1) if multidisciplinary teaching is effective in delivering surgical anatomy teaching,
(2) student’s learning preferences regarding this teaching method.
Results The questionnaire response rate was 89% (216 of 244 students; female: male ratio 1.25) and 42 students participated in 6 focus groups. Mean questionnaire responses indicated a favourable opinion on quality assurance items and multidisciplinary teaching. 81% of students agreed that multidisciplinary teaching enhanced learning and 86% felt that this did not adversely affect interaction. A positive contribution towards POEM learning was reported for Radiology (95% of students), Anatomy (93%) and Surgery (78%). The benefits of multidisciplinary teaching were congruent for Anatomy, Radiology and Surgery with 78% of students indicating a perceived favourable association with learning. Multidisciplinary teaching was not associated with diluted interaction, with 62% of students describing interaction as sufficient. 88% of students positively ranked tutor characteristics of enthusiasm and encouragement as being strongly associated with teacher quality. Positive perception of overall quality was strongly associated with learning preferences as well as more generic quality assurance issues (80% students; alpha coefficient 0.83).
The results were supported by triangulation of the above quantitative data with qualitative data generated by the focus groups. Whilst students frequently misunderstood the meaning of “multidisciplinary teaching”, there was an appreciation of the method’s worth; students recognised and valued the relevance of Anatomy, Radiology and Surgery teaching to POEM learning. The importance of vertically integrating Anatomy into all stages of the undergraduate curriculum was especially recognised.
Reference Aarnio M, Nieminen J, Pyorala E, Lindbolm-Ylanne S. Motivating medical students to learn. 2010 Med Teach;32(4):199-204.