74 resultados para Soluble fiber
Resumo:
This paper presents the design and implementation of a novel optical fiber temperature compensated relative humidity (RH) sensor device, based on fiber Bragg gratings (FBGs) and developed specifically for monitoring water ingress leading to the deterioration of building stone. The performance of the sensor thus created, together with that of conventional sensors, was first assessed in the laboratory where they were characterized under experimental conditions of controlled wetting and drying cycles of limestone blocks, before being employed “in-the-field” to monitor actual building stone in a specially built wall. Although a new construction, this was built specifically using conservation methods similar to those employed in past centuries, to allow an accurate simulation of processes occurring with wetting and drying in the historic walls in the University of Oxford.
Resumo:
Composites of recycled carbon fiber (CF) with up to 30 wt % loading with polyethylene (PE) were prepared via melt compounding. The morphology of the composites and the degree of dispersion of the CF in the PE matrix was examined using scanning electron microscopy, and revealed the CF to be highly dispersed at all loadings and strong interfacial adhesion to exist between the CF and PE. Raman and FTIR spectroscopy were used to characterize the surface chemistry and potential bonding sites of recycled CF. Both the Young's modulus and ultimate tensile stress increased with increasing CF loading, but the percentage stress at break was unchanged up to 5 wt % loading, then decreased with further successive addition of CF. The effect of CF on the elastic modulus of PE was examined using the Halpin-Tsai and modified Cox models, the former giving a better fit with the values determined experimentally. The electrical conductivity of the PE matrix was enhanced by about 11 orders of magnitude on addition of recycled CF with a percolation threshold of 7 and 15 wt % for 500-mu m and 3-mm thick samples. (c) 2007 Wiley Periodicals, Inc.
Resumo:
S-56
Resumo:
120
Resumo:
Increased plasma levels of cellular adhesion molecules (CAMs) have been shown to be predictors of all cause mortality in individuals with chronic renal failure 12 and patients with end-stage renal disease receiving haemodialysis 3. In renal transplant recipients the predictive value of CAMs has not been well characterised. The aim of this study was to assess the relationship between CAMs and all-cause mortality during prospective follow-up of a renal transplant cohort.
Resumo:
In this study, the changes in some of the cellular components of the immune system and the activity of the cytokine interleukin 2, important for immune activation and lymphocyte proliferation, were measured in a large cross-sectional study of all age groups including octogenarian and nonagenarian subjects. In 206 apparently well community-living subjects, the absolute lymphocyte count and T and B cell numbers fell a little in old and very old subjects. Within the T cell compartment, helper/inducer CD4+ T cells, together with their subsets identified as 'naive' (CD4+/CD45RA+) and 'memory' (CD4+/CD45RO+) cells, also showed a decline with increased age. The suppressor/cytotoxic CD8+ subset showed no age-related change. The levels of the cytokine interleukin 2 were very low in octogenarian and nonagenarian subjects, while the soluble interleukin 2 receptor levels increased with increasing age. The interleukin 2 levels were associated with number and percentage of the 'memory' (CD4+/CD45RO+) subset of T cells which mediates the host response to previously met antigens. Since the interleukin 2 values were very low in the oldest groups and were associated with a reduced 'memory' (CD4+/CD45RO+) compartment, this suggests a possible mechanism of why the very elderly subject is more susceptible to morbidity and mortality from infectious or other agents.
Resumo:
A plethora of studies have described the in vitro assessment of dissolving microneedle (MN) arrays for enhanced transdermal drug delivery, utilising a wide variety of model membranes as a representation of the skin barrier. However, to date, no discussion has taken place with regard to the choice of model skin membrane and the impact this may have on the evaluation of MN performance. In this study, we have, for the first time, critically assessed the most common types of in vitro skin permeation models - a synthetic hydrophobic membrane (Silescol(®) of 75 µm) and neonatal porcine skin of definable thickness (300-350 µm and 700-750 µm) - for evaluating the performance of drug loaded dissolving poly (methyl vinyl ether co maleic acid) (PMVE/MA) MN arrays. It was found that the choice of in vitro skin model had a significant effect on the permeation of a wide range of small hydrophilic molecules released from dissolving MNs. For example, when Silescol(®) was used as the model membrane, the cumulative percentage permeation of methylene blue 24h after the application of dissolvable MNs was found to be only approximately 3.7% of the total methylene blue loaded into the MN device. In comparison, when dermatomed and full thickness neonatal porcine skin were used as a skin model, approximately 67.4% and 47.5% of methylene blue loaded into the MN device was delivered across the skin 24h after the application of MN arrays, respectively. The application of methylene blue loaded MN arrays in a rat model in vivo revealed that the extent of MN-mediated percutaneous delivery achieved was most similar to that predicted from the in vitro investigations employing dermatomed neonatal porcine skin (300-350 µm) as the model skin membrane. On the basis of these results, a wider discussion within the MN community will be necessary to standardise the experimental protocols used for the evaluation and comparison of MN devices.
Resumo:
CTLA-4 is a crucial immune regulator that mediates both negative co-stimulation signals to T cells, and regulatory T (Treg) cell extrinsic control of effector responses. Here we present evidence supporting a novel mechanism for this extrinsic suppression, executed by the alternatively spliced soluble CTLA-4 isoform (sCTLA-4). Analyses of human T cells in vitro show that sCTLA-4 secretion can be increased during responses, and has potent inhibitory properties, since isoform-specific blockade of its activity significantly increased antigen-driven proliferation and cytokine (interferon-?, IL-17) secretion. Treg cells were demonstrated to be a prominent source of sCTLA-4, which contributed to suppression in vitro when their numbers were limiting. The soluble isoform was also produced by, and inhibited, murine T cells responding to antigen in vitro, and blockade of its activity in vivo protected against metastatic spread of melanoma in mice. We conclude that sCTLA-4 is an important immune regulator, responsible for at least some of the inhibitory effects previously ascribed to the membrane-bound isoform. These results suggest that the immune system exploits the different CTLA-4 isoforms for either intrinsic or extrinsic regulation of T-cell activity.
Resumo:
Morbidity and mortality have declined only modestly in patients with clinical acute lung injury (ALI) and acute respiratory distress syndrome (ARDS), despite extensive research into the pathophysiology. Current treatment remains primarily supportive with lung-protective ventilation and a fluid conservative strategy. Pharmacologic therapies that reduce the severity of lung injury in preclinical models have not yet been translated to effective clinical treatment options. Consequently, further research in translational therapies is needed. Cell-based therapy with mesenchymal stem cells (MSCs) is one attractive new therapeutic approach. MSCs have the capacity to secrete multiple paracrine factors that can regulate endothelial and epithelial permeability, decrease inflammation, enhance tissue repair, and inhibit bacterial growth. This review will focus on recent studies, which support the potential therapeutic use of MSCs in ALI/ARDS, with an emphasis on the role of paracrine soluble factors.