163 resultados para Parsons, Lewis B. (Lewis Baldwin), 1818-1907.
Resumo:
Measurements of the duration of X-ray lasing pumped with picosecond pulses from the VULCAN optical laser are obtained using a streak camera with 700 fs temporal resolution. Combined with a temporal smearing due to the spectrometer employed, we have measured X-ray laser pulse durations for Ni-like silver at 13.9 nm with a total time resolution of 1.1 ps. For Ni-like silver, the X-ray laser output has a steep rise followed by an approximately exponential temporal decay with measured full-width at half-maximum (FWHM) of 3.7 (+/-0.5) ps. For Ne-like nickel lasing at 23.1 nm, the measured duration of lasing is approximate to10.7 (+/-1) ps (FWHM). An estimate of the duration of the X-ray laser gain has been obtained by temporally resolving spectrally integrated continuum and resonance line emission. For Ni-like silver, this time of emission is approximate to22 (+/-2) ps (FWHM), while for Ne-like nickel we measure approximate to35 (+/-2) ps (FWHM). Assuming that these times of emission correspond to the gain duration, we show that a simple model consistently relates the gain durations to the measured durations of X-ray lasing. (C) 2002 Elsevier Science B.V. All rights reserved.
Resumo:
We have used XUV lasers to make absolute measurements of the photoabsorption coefficient of Al at energies just below that of the L3 absorption edge at 72.7 eV. Transmission measurements at photon energies of 53.7 and 63.3 eV have been made using Ne-like Ni and Ge XUV lasers. The XUV laser output was recorded in first and second orders using a flat-field spectrometer. Al foils with steps of various thicknesses were placed over the first order diffracted signal, while the second order diffraction was used to monitor the beam profile at each position. The transmission data agree extremely well with the original measurements at these wavelengths made by Henke and co-workers (Henke B L, Gullikson E M and Davis J C 1993 At. Data Nucl. Data Tables 54 18 1), but are in conflict with subsequent measurements which are currently in common use (Gullikson E M, Denham P, Mrowka S and Underwood J H 1994 Phys. Rev. B 49 16 283). The exact values of the absorption coefficients in this region of the spectrum have significant implications for the diagnosis of the energy and intensity output of XUV lasers.
Resumo:
The increase in the XUV mass absorption coefficient of liquid aluminium, produced by high-power-laser shock-compression, is measured using XUV laser radiography. At a photon energy of 63 eV a change in the mass absorption coefficient by up to a factor of similar to2.2 is determined at densities close to twice that of solid and electron temperatures of the order of 1 eV. Comparison with hydrodynamic simulations indicate that the absorption coefficient scales with density as rho (1.3 +/-0.2).
Resumo:
Choline saccharinate and choline acesulfamate are two examples of hydrophilic ionic liquids, which can be prepared from easily available starting materials (choline chloride and a non-nutritive sweetener). The (eco)toxicity of these ionic liquids in aqueous solution is very low in comparison to other types of ionic liquids. A general method for the synthesis and purification of hydrophilic ionic liquids is presented. The method consists of a silver-free metathesis reaction, followed by purification of the ionic liquid by ion-exchange chromatography. The crystal structures show a marked difference in hydrogen bonding between the two ionic liquids, although the saccharinate and the acesulfamate anions show structural similarities. The optimized structures, the energetics, and the charge distribution of cation-anion pairs in the ionic liquids were studied by density functional theory (DFT) and second-order (Moller-Plesset) perturbation theory calculations. The occupation of the non-Lewis orbitals was considered to obtain a qualitative picture of the Lewis structures. The calculated interaction energies and the dipole moments for the ion pairs in the gas phase were discussed.
Resumo:
Background: This is an update of a Cochrane review first published in The Cochrane Library in Issue 3, 2010.<br/>For many patients with head and neck cancer, oral nutrition will not provide adequate nourishment during treatment with radiotherapy or chemoradiotherapy due to the acute toxicity of treatment, obstruction caused by the tumour, or both. The optimal method of enteral feeding for this patient group has yet to be established.<br/><br/>Objectives: To compare the effectiveness of different enteral feeding methods used in the nutritional management of patients with head and neck cancer receiving radiotherapy or chemoradiotherapy using the clinical outcomes, nutritional status, quality of life and rates of complications. <br/><br/>Search methods: Our extensive search included the Cochrane ENT Group Trials Register, CENTRAL, PubMed, EMBASE, CINAHL, AMED and ISI Web of Science. The date of the most recent search was 13 February 2012.<br/><br/>Selection criteria:Randomised controlled trials comparing one method of enteral feeding with another, e.g. nasogastric (NG) or percutaneous endoscopic gastrostomy (PEG) feeding, for adult patients with a diagnosis of head and neck cancer receiving radiotherapy and/or chemoradiotherapy.<br/><br/>Data collection and analysis:Two authors independently assessed trial quality and extracted data using standardised forms. We contacted study authors for additional information.<br/><br/>Main results: One randomised controlled trial met the criteria for inclusion in this review. No further studies were identified when we updated the searches in 2012.<br/>Patients diagnosed with head and neck cancer, being treated with chemoradiotherapy, were randomised to PEG or NG feeding. In total only 33 patients were eligible for analysis as the trial was terminated early due to poor accrual. A high degree of bias was identified in the study.<br/>Weight loss was greater for the NG group at six weeks post-treatment than for the PEG group (P = 0.001). At six months post-treatment, however, there was no significant difference in weight loss between the two groups. Anthropometric measurements recorded six weeks post-treatment demonstrated lower triceps skin fold thickness for the NG group compared to the PEG group (P = 0.03). No statistically significant difference was found between the two different enteral feeding techniques in relation to complication rates or patient satisfaction. The duration of PEG feeding was significantly longer than for the NG group (P = 0.0006). In addition, the study calculated the cost of PEG feeding to be 10 times greater than that of NG, though this was not found to be significant. There was no difference in the treatment received by the two groups. However, four PEG fed patients and two NG fed patients required unscheduled treatment breaks of a median of two and six days respectively.<br/>We identified no studies of enteral feeding involving any form of radiologically inserted gastrostomy (RIG) feeding or comparing prophylactic PEG versus PEG for inclusion in the review.<br/><br/>Authors' conclusions: There is not sufficient evidence to determine the optimal method of enteral feeding for patients with head and neck cancer receiving radiotherapy and/or chemoradiotherapy. Further trials of the two methods of enteral feeding, incorporating larger sample sizes, are required.
Resumo:
A genome scan meta-analysis (GSMA) was carried out on 32 independent genome-wide linkage scan analyses that included 3255 pedigrees with 7413 genotyped cases affected with schizophrenia (SCZ) or related disorders. The primary GSMA divided the autosomes into 120 bins, rank-ordered the bins within each study according to the most positive linkage result in each bin, summed these ranks (weighted for study size) for each bin across studies and determined the empirical probability of a given summed rank (P-SR) by simulation. Suggestive evidence for linkage was observed in two single bins, on chromosomes 5q (142-168 Mb) and 2q (103-134 Mb). Genome-wide evidence for linkage was detected on chromosome 2q (119-152 Mb) when bin boundaries were shifted to the middle of the previous bins. The primary analysis met empirical criteria for 'aggregate' genome-wide significance, indicating that some or all of 10 bins are likely to contain loci linked to SCZ, including regions of chromosomes 1, 2q, 3q, 4q, 5q, 8p and 10q. In a secondary analysis of 22 studies of European-ancestry samples, suggestive evidence for linkage was observed on chromosome 8p (16-33 Mb). Although the newer genome-wide association methodology has greater power to detect weak associations to single common DNA sequence variants, linkage analysis can detect diverse genetic effects that segregate in families, including multiple rare variants within one locus or several weakly associated loci in the same region. Therefore, the regions supported by this meta-analysis deserve close attention in future studies. Molecular Psychiatry (2009) 14, 774-785; doi:10.1038/mp.2008.135; published online 30 December 2008
Resumo:
Thomson scattering from laser-induced plasma in atmospheric helium was used to obtain temporally and spatially resolved electron temperature and density profiles. Electron density measurements at 5 s after breakdown are compared with those derived from the separation of the allowed and forbidden components of the 447.1 nm He I line. Plasma is created using 9 ns, 140 mJ pulses from Nd:YAG laser at 1064 nm. Electron densities of ~5 × 10 cm are in good agreement with Thomson scattering measurements, benchmarking this emission line as a useful diagnostic for high density plasmas. © 2011 American Institute of Physics.
Resumo:
We report what is to our knowledge the first demonstration of a transient x-ray laser pumped by a 350-fs pulse in a traveling-wave irradiation geometry. For a 500-fs pump pulse the traveling-wave irradiation was found to have a strong effect on enhancing the Ni-like silver 4d-4p lasing emission at 13.9 nm. The signal enhancement was significantly less when the pulse duration was lengthened to 1.7 ps. The experimental observations are well reproduced by a simple model when the duration of gain is taken of the order of 15-20 ps. For the 500-fs pulse a gain coefficient of 14.5 cm(-1) was measured for plasma lengths up to 7 mm. Refraction of the amplified photons is believed to be the main cause of the limitation of the effective amplification length. (C) 2000 Optical Society of America.
Resumo:
The characteristics of an extreme-ultraviolet (XUV) continuum light source and its application to a dual-laser plasma (DLP) photoabsorption experiment are described. The continuum emitting plasma was formed by focusing a 7 ps, 248 nm, 15 mJ laser pulse onto a number of selected targets known to be good XUV continuum emitters (Sm, W, Au and Pb), while the second absorbing plasma was produced by a 15 ns, 1064 nm, 300 mi pulse. The duration of the continuum emission for these plasmas has a mean value of similar to 150 ps, but depends on both the target material and the picosecond laser pulse energy. Using this picosecond DLP set-up we have been able to measure the photoabsorption spectrum of an actinide ion (thorium) for the first time.