331 resultados para Orr, John
Resumo:
It is known that the method used to mix the liquid monomer and powder of PMMA bone cement influences the quality of the cement that is used in total joint replacements. Mixing theory indicates that the interaction between the liquid monomer and the powder is affected by a number of parameters, such as cement viscosity and degree of agitation, with this knowledge utilized in the design of cement mixing devices. Therefore, the objectives of this study were to: (i) obtain information on the interaction of the liquid monomer and the powder in the case of an PMMA bone cement, (ii) show how this knowledge can be applied to the design of an automated cement mixing device, and (iii) compare the porosity, bending modulus, and bending strength of one commercially-available cement prepared using the automated mixer and prepared using a conventional mixer that is in current clinical use. Experimental data indicated that increasing the velocity and decreasing the viscosity of the systems produced cement that improved mechanical properties, which may contribute to better mechanical integrity and, hence, reduced tendency for aseptic loosening, of cemented hip implants.
Resumo:
In this investigation Raman spectroscopy was shown to be a method that could be used to monitor the polymerisation of PMMA bone cement. Presently there is no objective method that orthopaedic surgeons can use to quantify the curing process of cement during surgery. Raman spectroscopy is a non-invasive, non-destructive technique that could offer such an option. Two commercially available bone cements (Palacos® R and SmartSet® HV) and different storage conditions (4 and 22°C) were used to validate the technique. Raman spectroscopy was found to be repeatable across all conditions with the completion of the polymerisation process particularly easy to establish. All tests were benchmarked against current temperature monitoring methods outlined in ISO and ASTM standards. There was found to be close agreement with the standard methods and the Raman spectroscopy used in this study.
Resumo:
The degradable polymers polylactide (PLA) and polylactide-co-glycolide (PLGA) have found widespread use in modern medical practice. However, their slow degradation rates and tendency to lose strength before mass have caused problems. The aim of this study was to ascertain whether treatment with e-beam radiation could address these problems. Samples of PLA and PLGA were manufactured and placed in layered stacks, 8.1 mm deep, before exposure to 50 kGy of e-beam radiation from a 1.5 MeV accelerator. Gel permeation chromatography testing showed that the molecular weight of both materials was depth-dependent following irradiation, with samples nearest to the treated surface showing a reduced molecular weight. Samples deeper than 5.4 mm were unaffected. Computer modeling of the transmission of a 1.5 MeV e-beam in these materials corresponded well with these findings. An accelerated mass-loss study of the treated materials found that the samples nearest the irradiated surface initiated mass loss earlier, and at later stages showed an increased percentage mass loss. It was concluded that e-beam radiation could modify the degradation of bioabsorbable polymers to potentially improve their performance in medical devices, specifically for improved orthopedic fixation.
Resumo:
This study investigated methyl methacrylate – polymethyl methacrylate powder bed interactions through droplet analyses, using model fluids and commercially available bone cement. The effects of storage temperature of liquid monomer and powder packing configuration on drop penetration time were investigated. Methyl methacrylate showed much more rapid imbibition than caprolactone due to decrease in both contact angle and fluid viscosity. Drop penetration of caprolactone through polymethyl methacrylate increased with decrease in bed macro-voids and increase in bulk density as predicted by the modified constant drawing area penetration model and confirmed by drop penetration images. Linear relationships were found between droplet mass and drawing area with imbibition time. Further experiments showed gravimetric analysis of the polymerised methyl methacrylate – polymethyl methacrylate matrix under various storage temperatures correlated with Reynolds number and Washburn analyses. These observations have direct implications for the design of mixing and delivery systems for acrylic bone cements used in orthopaedic surgery.
Resumo:
Predicable and controlled degradation is not only central to the accurate delivery of bioactive agents and drugs, it also plays a vital role in key aspects of bone tissue engineering. The work addressed in this paper investigates the utilisation of e-beam irradiation in order to achieve a controlled (surface) degradation profile. This study focuses on the modification of commercially and clinically relevant materials, namely poly(L-lactic acid) (PLLA), poly(L-lactide-hydroxyapatite) (PLLA-HA), poly(L-lactide-glycolide) co-polymer (PLG) and poly(L-lactide-DL-lactide) co-polymer (PLDL). Samples were subjected to irradiation treatments using a 0.5 MeV electron beam with delivered surface doses of 150 and 500 kGy. In addition, an acrylic attenuation shield was used for selected samples to control the penetration of the e-beam. E-beam irradiation induced chain scission in all polymers, as characterized by reduced molecular weights and glass transition temperatures (T-g). Irradiation not only produced changes in the physical properties of the polymers but also had associated effects on surface erosion of the materials during hydrolytic degradation. Moreover, the extent to which both mechanical and hydrolytic degradation was observed is synonymous with the estimated penetration of the beam (as controlled by the employment of an attenuation shield). (C) 2010 Acta Materialia Inc. Published by Elsevier Ltd. All rights reserved.