61 resultados para Microsphere-based array


Relevância:

30.00% 30.00%

Publicador:

Resumo:

We introduce a general scheme for sequential one-way quantum computation where static systems with long-living quantum coherence (memories) interact with moving systems that may possess very short coherence times. Both the generation of the cluster state needed for the computation and its consumption by measurements are carried out simultaneously. As a consequence, effective clusters of one spatial dimension fewer than in the standard approach are sufficient for computation. In particular, universal computation requires only a one-dimensional array of memories. The scheme applies to discrete-variable systems of any dimension as well as to continuous-variable ones, and both are treated equivalently under the light of local complementation of graphs. In this way our formalism introduces a general framework that encompasses and generalizes in a unified manner some previous system-dependent proposals. The procedure is intrinsically well suited for implementations with atom-photon interfaces.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

The paper presents IPPro which is a high performance, scalable soft-core processor targeted for image processing applications. It has been based on the Xilinx DSP48E1 architecture using the ZYNQ Field Programmable Gate Array and is a scalar 16-bit RISC processor that operates at 526MHz, giving 526MIPS of performance. Each IPPro core uses 1 DSP48, 1 Block RAM and 330 Kintex-7 slice-registers, thus making the processor as compact as possible whilst maintaining flexibility and programmability. A key aspect of the approach is in reducing the application design time and implementation effort by using multiple IPPro processors in a SIMD mode. For different applications, this allows us to exploit different levels of parallelism and mapping for the specified processing architecture with the supported instruction set. In this context, a Traffic Sign Recognition (TSR) algorithm has been prototyped on a Zedboard with the colour and morphology operations accelerated using multiple IPPros. Simulation and experimental results demonstrate that the processing platform is able to achieve a speedup of 15 to 33 times for colour filtering and morphology operations respectively, with a reduced design effort and time.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

We report on the investigations of spin wave modes in arrays of densely packed Co nanorods using Brillouin light scattering. We have observed a significant role of spin wave modes along the nanorod axis in contrast to infinite magnetic nanowires. Unusual optical properties featuring an inverted Stokes/anti-Stokes asymmetry of the Brillouin scattering spectra have been observed. The spectrum of spin wave modes in the nanorod array has been calculated and compared with the experiment. Experimental observations are explained in terms of a combined numerical-analytical approach taking into account both the low aspect ratio of individual magnetic nanorods and dipolar magnetic coupling between the nanorods in the array. The optical studies of spin-wave modes in the metamaterials with low aspect ratio nanorods have revealed new magnetic and magneto-optical properties compared to continuous magnetic films or infinite magnetic nanowires. Such magnetic metamaterials are important class of active metamaterials needed for prospective data storage and signal processing applications. (c) 2012 Optical Society of America

Relevância:

30.00% 30.00%

Publicador:

Resumo:

The motivation for this study was to reduce physics workload relating to patient- specific quality assurance (QA). VMAT plan delivery accuracy was determined from analysis of pre- and on-treatment trajectory log files and phantom-based ionization chamber array measurements. The correlation in this combination of measurements for patient-specific QA was investigated. The relationship between delivery errors and plan complexity was investigated as a potential method to further reduce patient-specific QA workload. Thirty VMAT plans from three treatment sites - prostate only, prostate and pelvic node (PPN), and head and neck (H&N) - were retrospectively analyzed in this work. The 2D fluence delivery reconstructed from pretreatment and on-treatment trajectory log files was compared with the planned fluence using gamma analysis. Pretreatment dose delivery verification was also car- ried out using gamma analysis of ionization chamber array measurements compared with calculated doses. Pearson correlations were used to explore any relationship between trajectory log file (pretreatment and on-treatment) and ionization chamber array gamma results (pretreatment). Plan complexity was assessed using the MU/ arc and the modulation complexity score (MCS), with Pearson correlations used to examine any relationships between complexity metrics and plan delivery accu- racy. Trajectory log files were also used to further explore the accuracy of MLC and gantry positions. Pretreatment 1%/1 mm gamma passing rates for trajectory log file analysis were 99.1% (98.7%-99.2%), 99.3% (99.1%-99.5%), and 98.4% (97.3%-98.8%) (median (IQR)) for prostate, PPN, and H&N, respectively, and were significantly correlated to on-treatment trajectory log file gamma results (R = 0.989, p < 0.001). Pretreatment ionization chamber array (2%/2 mm) gamma results were also significantly correlated with on-treatment trajectory log file gamma results (R = 0.623, p < 0.001). Furthermore, all gamma results displayed a significant correlation with MCS (R > 0.57, p < 0.001), but not with MU/arc. Average MLC position and gantry angle errors were 0.001 ± 0.002 mm and 0.025° ± 0.008° over all treatment sites and were not found to affect delivery accuracy. However, vari- ability in MLC speed was found to be directly related to MLC position accuracy. The accuracy of VMAT plan delivery assessed using pretreatment trajectory log file fluence delivery and ionization chamber array measurements were strongly correlated with on-treatment trajectory log file fluence delivery. The strong corre- lation between trajectory log file and phantom-based gamma results demonstrates potential to reduce our current patient-specific QA. Additionally, insight into MLC and gantry position accuracy through trajectory log file analysis and the strong cor- relation between gamma analysis results and the MCS could also provide further methodologies to both optimize the VMAT planning and QA process. 

Relevância:

30.00% 30.00%

Publicador:

Resumo:

The Field Programmable Gate Array (FPGA) implementation of the commonly used Histogram of Oriented Gradients (HOG) algorithm is explored. The HOG algorithm is employed to extract features for object detection. A key focus has been to explore the use of a new FPGA-based processor which has been targeted at image processing. The paper gives details of the mapping and scheduling factors that influence the performance and the stages that were undertaken to allow the algorithm to be deployed on FPGA hardware, whilst taking into account the specific IPPro architecture features. We show that multi-core IPPro performance can exceed that of against state-of-the-art FPGA designs by up to 3.2 times with reduced design and implementation effort and increased flexibility all on a low cost, Zynq programmable system.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

This paper proposes a new thermography-based maximum power point tracking (MPPT) scheme to address photovoltaic (PV) partial shading faults. Solar power generation utilizes a large number of PV cells connected in series and in parallel in an array, and that are physically distributed across a large field. When a PV module is faulted or partial shading occurs, the PV system sees a nonuniform distribution of generated electrical power and thermal profile, and the generation of multiple maximum power points (MPPs). If left untreated, this reduces the overall power generation and severe faults may propagate, resulting in damage to the system. In this paper, a thermal camera is employed for fault detection and a new MPPT scheme is developed to alter the operating point to match an optimized MPP. Extensive data mining is conducted on the images from the thermal camera in order to locate global MPPs. Based on this, a virtual MPPT is set out to find the global MPP. This can reduce MPPT time and be used to calculate the MPP reference voltage. Finally, the proposed methodology is experimentally implemented and validated by tests on a 600-W PV array

Relevância:

30.00% 30.00%

Publicador:

Resumo:

As part of any drilling cuttings pile removal process the requirement for monitoring the release of contaminants into the marine environment will be critical. Traditional methods for such monitoring involve taking samples for laboratory analysis. This process is time consuming and only provides data on spot samples taken from a limited number of locations and time frames. Such processes, therefore, offer very restricted information. The need for improved marine sensors for monitoring contaminants is established. We report here the development and application of a multi-capability optical sensor for the real-time in situ monitoring of three key marine environmental and offshore/oil parameters: hydrocarbons, synthetic-based fluids and heavy metal concentrations. The use of these sensors will be a useful tool for real-time in situ environmental monitoring during the process of decommissioning offshore structures. Multi-capability array sensors could also provide information on the dispersion of contamination from drill cuttings piles either while they are in situ or during their removal.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

The fabrication and operation of an ammonia chemoresistor is described. The sensor responds to changes in the resistance (impedance) of a thin layer of conductive polymer is due to changes in ammonia concentration. The polyaniline film was deposited by electroless plating (dipping) method on interdigitated array made by photolithographic technique. The PANI film was characterized by UV/VIS and IR Spectroscopy and respectively, Atomic Force Microscopy. Impedance Spectroscopy was used for sensor characterization

Relevância:

30.00% 30.00%

Publicador:

Resumo:

The introduction of microarray technology to the scientific and medical communities has dramatically changed the way in which we now address basic biomedical questions. Expression profiling using microarrays facilitates an experimental approach where alterations in the transcript level of entire transcriptomes can be simultaneously assayed in response to defined stimuli. We have used microarray analysis to identify downstream transcriptional targets of the BRCA1 (Breast Cancer 1) tumour-suppressor gene as a means of defining its function. BRCA1 has been implicated in the predisposition to early onset breast and ovarian cancer and while its exact function remains to be defined, roles in DNA repair, cell-cycle control and transcriptional regulation have been implied. In the current study we have generated cell lines with tetracycline-regulated, inducible expression of BRCA1 as a tool to identify genes, which might represent important effectors of BRCA1 function. Oligonucleotide array-based expression profiling identified a number of genes that were upregulated at various times following inducible expression of BRCA1 including the DNA damage-responsive gene GADD45 (Growth Arrest after DNA Damage). Identified targets were confirmed by Northern blot analysis and their functional significance as BRCA1 targets examined.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

The introduction of microarray technology to the scientific and medical communities has fundamentally altered the way in which we now address basic biomedical questions. Microarrays technology facilitates a more complete and inclusive experimental approach where alterations in the transcript level of entire genomes can be simultaneously assayed in response to a variety of stimuli. Conceptually different approaches to the development of microarray technology have resulted in the generation of two different array formats: oligonucleotide arrays and cDNA arrays. The application of microarray and related technologies to identify specific targets of defined genes that have clearly been implicated in cancer progression requires a specific experimental approach. The objective of tiffs approach is to define changes in transcriptional profile that occur in response to modulating the expression level of the gene to be studied. The resulting altered expression profile can then be viewed as a blueprint by which that gene effects its cellular function. We have used oligonucleotide array-based expression profiling in collaboration with Affymetrix to identify downstream transcriptional targets of the BRCA1 tumor-suppressor gene as a means of defining its function. BRCA1 has been implicated in at least three functional pathways, namely, mediating the cellular response to DNA damage, as a cell cycle checkpoint protein and in the regulation of transcription. The physiological significance of these properties and their implications for the function of BRCA1 as a tumor-suppressor gene remain to be defined.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Due to its efficiency and simplicity, the finite-difference time-domain method is becoming a popular choice for solving wideband, transient problems in various fields of acoustics. So far, the issue of extracting a binaural response from finite difference simulations has only been discussed in the context of embedding a listener geometry in the grid. In this paper, we propose and study a method for binaural response rendering based on a spatial decomposition of the sound field. The finite difference grid is locally sampled using a volumetric array of receivers, from which a plane wave density function is computed and integrated with free-field head related transfer functions, in the spherical harmonics domain. The volumetric array is studied in terms of numerical robustness and spatial aliasing. Analytic formulas that predict the performance of the array are developed, facilitating spatial resolution analysis and numerical binaural response analysis for a number of finite difference schemes. Particular emphasis is placed on the effects of numerical dispersion on array processing and on the resulting binaural responses. Our method is compared to a binaural simulation based on the image method. Results indicate good spatial and temporal agreement between the two methods.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Assessment of Human papillomavirus (HPV) prevalence and genotype distribution is important for monitoring the impact of prophylactic HPV vaccination. This study aimed to demonstrate the HPV genotypes predominating in pre-malignant and cervical cancers in Northern Ireland (NI) before the vaccination campaign has effect. Formalin fixed paraffin embedded tissue blocks from 2,303 women aged 16-93 years throughout NI were collated between April 2011 and February 2013. HPV DNA was amplified by PCR and HPV genotyping undertaken using the Roche® linear array detection kit. In total, 1,241 out of 1,830 eligible samples (68.0%) tested positive for HPV, with the majority of these [1,181/1,830 (64.5%)] having high-risk (HR) HPV infection; 37.4% were positive for HPV-16 (n=684) and 5.1% for HPV-18 (n=93). HPV type-specific prevalence was 48.1%, 65.9%, 81.3%, 92.2%, and 64.3% among cervical intraepithelial neoplasias (CIN) Grades I-III, squamous cell carcinomas (SCC) and adenocarcinoma (AC) cases, respectively. Most SCC cases (81.3%) had only one HPV genotype detected and almost a third (32.0%) of all cervical pathologies were HPV negative including 51.9% of CIN I (n=283), 34.1% CIN II (n=145), 18.7% of CIN III (n=146), 7.8% of SCC (n=5), and 35.7% of AC (n=5) cases. This study provides important baseline data for monitoring the effect of HPV vaccination in NI and for comparison with other UK regions. The coverage of other HR-HPV genotypes apart from 16 and 18, including HPV-45, 31, 39, and 52, and the potential for cross protection, should be considered when considering future polyvalent vaccines.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Homomorphic encryption offers potential for secure cloud computing. However due to the complexity of homomorphic encryption schemes, performance of implemented schemes to date have been unpractical. This work investigates the use of hardware, specifically Field Programmable Gate Array (FPGA) technology, for implementing the building blocks involved in somewhat and fully homomorphic encryption schemes in order to assess the practicality of such schemes. We concentrate on the selection of a suitable multiplication algorithm and hardware architecture for large integer multiplication, one of the main bottlenecks in many homomorphic encryption schemes. We focus on the encryption step of an integer-based fully homomorphic encryption (FHE) scheme. We target the DSP48E1 slices available on Xilinx Virtex 7 FPGAs to ascertain whether the large integer multiplier within the encryption step of a FHE scheme could fit on a single FPGA device. We find that, for toy size parameters for the FHE encryption step, the large integer multiplier fits comfortably within the DSP48E1 slices, greatly improving the practicality of the encryption step compared to a software implementation. As multiplication is an important operation in other FHE schemes, a hardware implementation using this multiplier could also be used to improve performance of these schemes.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Multiple myeloma is characterized by genomic alterations frequently involving gains and losses of chromosomes. Single nucleotide polymorphism (SNP)-based mapping arrays allow the identification of copy number changes at the sub-megabase level and the identification of loss of heterozygosity (LOH) due to monosomy and uniparental disomy (UPD). We have found that SNP-based mapping array data and fluorescence in situ hybridization (FISH) copy number data correlated well, making the technique robust as a tool to investigate myeloma genomics. The most frequently identified alterations are located at 1p, 1q, 6q, 8p, 13, and 16q. LOH is found in these large regions and also in smaller regions throughout the genome with a median size of 1 Mb. We have identified that UPD is prevalent in myeloma and occurs through a number of mechanisms including mitotic nondisjunction and mitotic recombination. For the first time in myeloma, integration of mapping and expression data has allowed us to reduce the complexity of standard gene expression data and identify candidate genes important in both the transition from normal to monoclonal gammopathy of unknown significance (MGUS) to myeloma and in different subgroups within myeloma. We have documented these genes, providing a focus for further studies to identify and characterize those that are key in the pathogenesis of myeloma.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

With security and surveillance, there is an increasing need to process image data efficiently and effectively either at source or in a large data network. Whilst a Field-Programmable Gate Array (FPGA) has been seen as a key technology for enabling this, the design process has been viewed as problematic in terms of the time and effort needed for implementation and verification. The work here proposes a different approach of using optimized FPGA-based soft-core processors which allows the user to exploit the task and data level parallelism to achieve the quality of dedicated FPGA implementations whilst reducing design time. The paper also reports some preliminary
progress on the design flow to program the structure. An implementation for a Histogram of Gradients algorithm is also reported which shows that a performance of 328 fps can be achieved with this design approach, whilst avoiding the long design time, verification and debugging steps associated with conventional FPGA implementations.