66 resultados para Lie detectors and detection


Relevância:

100.00% 100.00%

Publicador:

Resumo:

The authors are concerned with the development of computer systems that are capable of using information from faces and voices to recognise people's emotions in real-life situations. The paper addresses the nature of the challenges that lie ahead, and provides an assessment of the progress that has been made in the areas of signal processing and analysis techniques (with regard to speech and face), and the psychological and linguistic analyses of emotion. Ongoing developmental work by the authors in each of these areas is described.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Photometric transit surveys promise to complement the currently known sample of extra-solar planets (ESPs) by providing additional information on the planets and especially their radii. Here, we present ESP candidates from one such survey called, the Wide Angle Search for Planets (WASP) obtained with the SuperWASP wide-field imaging system. Observations were taken with SuperWASP North located in La Palma during the 2004 April to October observing season. The data cover fields between 23 and 03 h in RA at declinations above +12. This amounts to over ~400000 stars with V magnitudes 8-13.5. For the stars brighter than 12.5, we achieve better than 1 per cent photometric precision. Here, we present 41 sources with low-amplitude variability between ~1 and 10 mmag, from which we select 12 with periods between 1.2 and 4.4 d as the most promising ESP candidates. We discuss the properties of these ESP candidates, the expected fraction of transits recovered for our sample and implications for the frequency and detection of hot-Jupiters.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Non-invasive real time in vivo molecular imaging in small animal models has become the essential bridge between in vitro data and their translation into clinical applications. The tremendous development and technological progress, such as tumour modelling, monitoring of tumour growth and detection of metastasis, has facilitated translational drug development. This has added to our knowledge on carcinogenesis. The modalities that are commonly used include Magnetic Resonance Imaging (MRI), Computed Tomography (CT), Positron Emission Tomography (PET), bioluminescence imaging, fluorescence imaging and multi-modality imaging systems. The ability to obtain multiple images longitudinally provides reliable information whilst reducing animal numbers. As yet there is no one modality that is ideal for all experimental studies. This review outlines the instrumentation available together with corresponding applications reported in the literature with particular emphasis on cancer research. Advantages and limitations to current imaging technology are discussed and the issues concerning small animal care during imaging are highlighted.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

PURPOSE. It has been argued that the threshold for detecting frequency-doubling (FD) technology perimeter stimuli differs from the threshold for perceiving spatial structure (pattern) in the same targets. Thresholds for perceiving spatial structure have typically been assessed using orientation-identification experiments. The authors investigated the influence of orientation, edge profile, and psychophysical method on the origin of the reported differences in detection and orientation-identification thresholds for FD gratings.

METHODS. Detection and orientation-identification thresholds were determined in 12 observers with the use of FD stimuli (0.25 cyc/deg, 25 Hz) presented centrally and at 15° eccentricity. Edge profile (square- and Gaussian-windowed) and orientation (horizontal, vertical, and oblique) were independently modified. Detection thresholds were also measured for spatially uniform flickering targets (25 Hz). Orientation-identification thresholds using a two-alternative forced choice (2-AFC) and a two-interval forced choice (2-IFC) method were also compared in five experienced observers.

RESULTS. Orientation-identification and detection thresholds did not significantly differ under any condition tested. Orientation-identification thresholds obtained with 2-AFC were not significantly different from those obtained with 2-IFC. Thresholds for spatially uniform flicker were significantly lower than for FD stimuli.

CONCLUSIONS. The authors found that orientation-identification and detection thresholds for FD gratings did not differ and argue that recent findings to the contrary arise from the inappropriate use of spatially uniform flicker targets as alternatives in 2-IFC experiments.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Estimation and detection of the hemodynamic response (HDR) are of great importance in functional MRI (fMRI) data analysis. In this paper, we propose the use of three H 8 adaptive filters (finite memory, exponentially weighted, and time-varying) for accurate estimation and detection of the HDR. The H 8 approach is used because it safeguards against the worst case disturbances and makes no assumptions on the (statistical) nature of the signals [B. Hassibi and T. Kailath, in Proc. ICASSP, 1995, vol. 2, pp. 949-952; T. Ratnarajah and S. Puthusserypady, in Proc. 8th IEEE Workshop DSP, 1998, pp. 1483-1487]. Performances of the proposed techniques are compared to the conventional t-test method as well as the well-known LMSs and recursive least squares algorithms. Extensive numerical simulations show that the proposed methods result in better HDR estimations and activation detections.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

The correlated process of photodetaching two electrons from the F- ion following the absorption of a single photon has been investigated over an energy range 20-62 eV. In the experiment, a beam of photons from the Advanced Light Source was collinearly merged with a counter-propagating beam of F- ions from a sputter ion source. The F+ ions produced in the interaction region were detected, and the normalized signal was used to monitor the relative cross section for the double-detachment reaction. An absolute scale for the cross section was established by measuring the spatial overlap of the two beams and by determining the efficiency for collection and detection of the F+ ions. The measured cross section is compared with R-matrix and random phase approximation calculations. These calculations show that the Auger decay of the 2s2p(6) core-excited state of the F atom plays a minor role in the production of F+ ions and that double detachment is likely to be dominated by simultaneous correlated ejection of two valence electrons at energies well above threshold.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

A new microfluidic-based approach to measuring liquid thermal conductivity is developed to address the requirement in many practical applications for measurements using small (microlitre) sample size and integration into a compact device. The approach also gives the possibility of high-throughput testing. A resistance heater and temperature sensor are incorporated into a glass microfluidic chip to allow transmission and detection of a planar thermal wave crossing a thin layer of the sample. The device is designed so that heat transfer is locally one-dimensional during a short initial time period. This allows the detected temperature transient to be separated into two distinct components: a short-time, purely one-dimensional part from which sample thermal conductivity can be determined and a remaining long-time part containing the effects of three-dimensionality and of the finite size of surrounding thermal reservoirs. Identification of the one-dimensional component yields a steady temperature difference from which sample thermal conductivity can be determined. Calibration is required to give correct representation of changing heater resistance, system layer thicknesses and solid material thermal conductivities with temperature. In this preliminary study, methanol/water mixtures are measured at atmospheric pressure over the temperature range 30-50A degrees C. The results show that the device has produced a measurement accuracy of within 2.5% over the range of thermal conductivity and temperature of the tests. A relation between measurement uncertainty and the geometric and thermal properties of the system is derived and this is used to identify ways that error could be further reduced.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

We propose a hybrid approach to the experimental assessment of the genuine quantum features of a general system consisting of microscopic and macroscopic parts. We infer entanglement by combining dichotomic measurements on a bidimensional system and phase-space inference through the Wigner distribution associated with the macroscopic component of the state. As a benchmark, we investigate the feasibility of our proposal in a bipartite-entangled state composed of a single-photon and a multiphoton field. Our analysis shows that, under ideal conditions, maximal violation of a Clauser-Horne-Shimony-Holt-based inequality is achievable regardless of the number of photons in the macroscopic part of the state. The difficulty in observing entanglement when losses and detection inefficiency are included can be overcome by using a hybrid entanglement witness that allows efficient correction for losses in the few-photon regime.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

A rapid liquid chromatography tandem mass spectrometry (LC-MS/MS) method has been developed and validated for the simultaneous identification, confirmation and quantitation of seven licensed anti-inflammatory drugs (AIDS) in bovine milk. The method was validated in accordance with the criteria defined in Commission Decision 2002/657/EC. Two classes of AIDS were investigated, corticosteroids and non-steroidal anti-inflammatory drugs (NSAIDs). The developed method is capable of detecting and confirming dexamethasone (DXM), betamethasone (BTM), prednisolone (FRED), tolfenamic acid (TV), 5-hydroxy flunixin (5-OH-FLU). meloxicam (MLX) and 4-methyl amino antipyrine (4-MAA) at their associated maximum residue limits (MRLs). These compounds represent all the corticosteroids and NSAIDs licensed for use in bovine animals producing milk for human consumption. These compounds have never been analysed before in the same method and also 4-methyl amino antipyrine has never been analysed with the other licensed NSAIDs. The method can be considered rapid as permits the analysis of up to 30 samples in one day. Milk samples are extracted with acetonitrile; sodium chloride is added to aid partition of the milk and acetonitrile mixture. The acetonitrile extract is then subjected to liquid-liquid purification by the addition of hexane. The purified extract is finally evaporated to dryness and reconstituted in a water/acetonitrile mixture and determination is carried out by LC-MS/MS. Decision limit (CC alpha) values and detection capability (CC beta) values have been established for each compound. (C) 2009 Elsevier B.V. All rights reserved.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

A simple Langmuir probe technique has been used to measure the electron density, electron temperature, and plasma potential in the late stages (>5 mu s) of a laser ablated plasma plume. In the plasma, formed following 248 nm laser irradiation of a copper target, in vacuum at a laser fluence of 2.5 J cm(-2), electron densities of similar to 10(18) m(-3) and temperatures of similar to 0.5 eV were measured. These values are comparable with those reported previously using Faraday cup detectors and optical emission spectroscopy, respectively. (C) 1997 American Institute of Physics.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Geoscience methods are increasingly being utilised in criminal, environmental and humanitarian forensic investigations, and the use of such methods is supported by a growing body of experimental and theoretical research. Geoscience search techniques can complement traditional methodologies in the search for buried objects, including clandestine graves, weapons, explosives, drugs, illegal weapons, hazardous waste and vehicles. This paper details recent advances in search and detection methods, with case studies and reviews. Relevant examples are given, together with a generalised workflow for search and suggested detection technique(s) table. Forensic geoscience techniques are continuing to rapidly evolve to assist search investigators to detect hitherto difficult to locate forensic targets.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

The relationship between the biological activity of NO and its chemistry is complex. The objectives of this study were to investigate the influence of oxygen tension on the cytotoxicity of the NO• donor DETA/NO and to determine the effects of oxygen tension on the key RNS (reactive nitrogen species) responsible for any subsequent toxicity. The findings presented in this study indicate that the DETA/NO-mediated cytotoxic effects were enhanced under hypoxic conditions. Further investigations revealed that neither ONOO⁻ (peroxynitrite) nor nitroxyl was generated. Fluorimetric analysis in the presence of scavengers suggest for the first time that another RNS, dinitrogen trioxide may be responsible for the cytotoxicity with DETA/NO. Results showed destabilization of HIF (hypoxia inducible factor)-1α and depletion of GSH levels following the treatment with DETA/NO under hypoxia, which renders cells more susceptible to DETA/NO cytotoxicity, and could account for another mechanism of DETA/NO cytotoxicity under hypoxia. In addition, there was significant accumulation of nuclear p53, which showed that p53 itself might be a target for S-nitrosylation following the treatment with DETA/NO. Both the intrinsic apoptotic pathway and the Fas extrinsic apoptotic pathway were also activated. Finally, GAPDH (glyceraldehyde-3-phosphate dehydrogenase) is another important S-nitrosylated protein that may possibly play a key role in DETA/NO-mediated apoptosis and cytotoxicity. Therefore this study elucidates further mechanisms of DETA/NO mediated cytotoxicity with respect to S-nitrosylation that is emerging as a key player in the signalling and detection of DETA/NO-modified proteins in the tumour microenvironment.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Objective: To compare caries incidence following two different tooth replacement strategies for partially dentate older patients; namely functionally orientated treatment according to the principles of the Shortened Dental Arch (SDA) and conventional treatment using Removable Partial Dentures (RPDs). Method:A randomised controlled clinical trial (RCT) was conducted of partially dentate patients aged 65 years and older. Patients were randomly allocated to two different treatment groups: the RPD group and the SDA group. Each member of the RPD group was restored to complete arches with cobalt-chromium RPDs used to replace missing teeth. Patients in the SDA group were restored to a shortened arch of 10 occluding pairs of natural and replacement teeth using adhesive bridgework. All of the operative treatment was completed by a single operator. Caries incidence was measured over a 2-year period following treatment intervention and recorded using the International Caries and Detection System (ICDAS). Result:In total, 89 patients completed the RCT (45 SDAs and 44 RPDs). Patients in the RPD group recorded a significantly higher incidence of new carious lesions (p<0.001) and recurrent carious lesions (p<0.001) compared to the SDA group. A mixed model of covariance (ANCOVA) revealed that treatment group (p<0.001) and co-morbidity (p<0.001) were significant predictors of caries incidence. Conclusion:Two years after provision of prosthodontic treatment there was a significantly higher incidence of new and recurrent caries lesions in subjects provided with RPDs compared with SDA treatment. This will have a significant impact on the ongoing maintenance costs for these two treatment groups.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Intake of heterocyclic amines (HCAs, carcinogens produced during cooking of meat/fish, the most abundant being PhIP, DiMeIQx and MeIQx) is influenced by many factors including type/thickness of meat and cooking method/temperature/duration. Thus, assessment of HCA dietary exposure is difficult. Protein adducts of HCAs have been proposed as potential medium-term biomarkers of exposure, e.g. PhIP adducted to serum albumin or haemoglobin. However, evidence is still lacking that HCA adducts are viable biomarkers in humans consuming normal diets. The FoodCAP project, supported by World Cancer Research Fund, developed a highly sensitive mass spectrometric method for hydrolysis, extraction and detection of acid-labile HCAs in blood and assessed their validity as biomarkers of exposure. Multiple acid/alkaline hydrolysis conditions were assessed, followed by liquid-liquid extraction, clean-up by cation-exchange SPE and quantification by UPLC-ESI-MS/ MS. Blood was analysed from volunteers who completed food diaries to estimate HCA intake based on the US National Cancer Institute’s CHARRED database. Standard HCAs were recovered quantitatively from fortified blood. In addition, PhIP/MeIQx adducts bound to albumin and haemoglobin prepared in vitro using a human liver microsome system were also detectable in blood fortified at low ppt concentrations. However, except for one sample (5pg/ml PhIP), acid-labile PhIP, 7,8-DiMeIQx, 4,8-DiMeIQx and MeIQx were not observed above the 2pg/ml limit of detection in plasma (n=35), or in serum, whole blood or purified albumin, even in volunteers with high meat consumption (nominal HCA intake >2µg/day). It is concluded that HCA blood protein adducts are not viable biomarkers of exposure. Untargeted metabolomic analyses may facilitate discovery of suitable markers.