68 resultados para Let operating profitability
Resumo:
A compact differential 4-way power combiner with 2.3 dB loss and high common-mode rejection characteristic for use in mm-wave PAs is presented. A complete circuit comprised of a power splitter, two-stage cascode PA array, and a power combiner was implemented in SiGe technology. Measured small-signal gain of at least 17 dB was obtained from 74.5 GHz to 80.5 GHz with a peak 21 dB at 79 GHz. The prototype delivered 13.2 dBm P1dB and 14.3 dBm Psat when operated from a single 3.3 V supply at 75 GHz.
Resumo:
This paper describes the design, implementation, and characterization of a new type of passive power splitting and combining structure for use in a differential four-way power-combining amplifier operating at E-band. In order to achieve lowest insertion loss, input and output coils inductances are resonated with shunt capacitances. Simple C-L-C and L-C networks are proposed in order to compensate inductive loading due to routing line that would otherwise introduce mismatch and increase loss. Across 78-86 GHz band, measured insertion loss is about 7 dB. Measured return losses are >10 dB from 73 GHz to 94 GHz at the input port and >9 dB from 60 GHz to 94 GHz at the output port. When integrated with driver and power amplifier cells, the simulated complete circuit exhibits 18.2 dB gain and 20.3 dBm saturated output power.
Resumo:
Lipoxins, which are endogenously produced lipid mediators, promote the resolution of inflammation, and may inhibit fibrosis, suggesting a possible role in modulating renal disease. Here, lipoxin A4 (LXA4) attenuated TGF-ß1-induced expression of fibronectin, N-cadherin, thrombospondin, and the notch ligand jagged-1 in cultured human proximal tubular epithelial (HK-2) cells through a mechanism involving upregulation of the microRNA let-7c. Conversely, TGF-ß1 suppressed expression of let-7c. In cells pretreated with LXA4, upregulation of let-7c persisted despite subsequent stimulation with TGF-ß1. In the unilateral ureteral obstruction model of renal fibrosis, let-7c upregulation was induced by administering an LXA4 analog. Bioinformatic analysis suggested that targets of let-7c include several members of the TGF-ß1 signaling pathway, including the TGF-ß receptor type 1. Consistent with this, LXA4-induced upregulation of let-7c inhibited both the expression of TGF-ß receptor type 1 and the response to TGF-ß1. Overexpression of let-7c mimicked the antifibrotic effects of LXA4 in renal epithelia; conversely, anti-miR directed against let-7c attenuated the effects of LXA4. Finally, we observed that several let-7c target genes were upregulated in fibrotic human renal biopsies compared with controls. In conclusion, these results suggest that LXA4-mediated upregulation of let-7c suppresses TGF-ß1-induced fibrosis and that expression of let-7c targets is dysregulated in human renal fibrosis.
Resumo:
Practical demonstration of the operational advantages gained through the use of a co-operating retrodirective array (RDA) basestation and Van Atta node arrangements is discussed. The system exploits a number of inherent RDA features to provide analogue real time multifunctional operation at low physical complexity. An active dual-conversion four element RDA is used as the power distribution source (basestation) while simultaneously achieving a receive sensitivity level of ??109 dBm and 3 dB automatic beam steering angle of ??45??. When mobile units are each equipped with a semi-passive four element Van Atta array, it is shown mobile device orientation issues are mitigated and optimal energy transfer can occur because of automatic beam formation resulting from retrodirective self-pointing action. We show that operation in multipath rich environments with or without line of sight acts to reduce average power density limits in the operating volume with high energy density occurring at mobile nodes sites only. The system described can be used as a full duplex ASK communications link, or, as a means for remote node charging by wireless means, thereby enhancing deployment opportunities between unstabilised moving platforms.
Resumo:
A correlation interferometer working with a cooperation target operating at 2.2GHz center frequency is presented. This simplified interferometer presented here uses a
lock-in amplifier to significantly increase system sensitivity when used in conjunction with a co-operating target signaling using amplitude modulation. The system is verified by detecting the angular velocity of passing tagged target. Experimental results show detectable range up over 110 meters in a multipath environment using a 10dBm EIRP tag.
Resumo:
Single and double layer frequency selective surfaces (FSS) for Circular polarization (CP) operation were designed. The designed FSS provide reflection in the Ku-band (11.7 – 12.75 GHz) and transmission in the Ka-band (17.3 – 20.2 GHz). CP is conserved in each of the bands. For the double layer design over the Ku-band the reflection loss was less than 0.05 dB for TE and TM polarizations while the axial ratio was below 0.2 dB. Over the Ka-band transmission loss and axial ratio were each less than 0.25 dB.
Resumo:
A new variant of Class-EF power amplifier (PA), the so-called third-harmonic-peaking Class-EF, is presented. It inherits a soft-switching operation from the Class-E PA and a low peak switch voltage from the Class-F PA. More importantly, the new topology allows operations at higher frequencies and permits deployment of large transistors which is normally prohibited since they are always accompanied with high output capacitances. Using a simple transmission-line load network, the PA is synthesized to satisfy Class-EF impedances at fundamental frequency, third harmonic, and all even harmonics as well as to simultaneously provide an impedance matching to 50-Ω load.
Resumo:
Objective: The present study aimed to examine the role of health in consumers’ food purchasing decisions through investigating the nature of people’s discourse regarding health while conducting their food shopping.
Design: The study employed the think-aloud technique as part of an accompanied shop. All mentions of health and terms relating to health were identified from the data set. Inductive thematic analysis was conducted to examine how health was talked about in relation to people’s food choice decisions.
Setting: Supermarkets in Dublin, Republic of Ireland and Belfast, Northern Ireland.
Subjects Participants: (n 50) were aged over 18 years and represented the main household shopper.
Results: Responsibility for others and the perceived need to illicit strict control to avoid ‘unhealthy’ food selections played a dominant role in how health was talked about during the accompanied shop. Consequently healthy shopping was viewed as difficult and effort was required to make the healthy choice, with shoppers relating to product-based inferences to support their decisions.
Conclusions: This qualitative exploration has provided evidence of a number of factors influencing the consideration of health during consumers’ food shopping. These results highlight opportunities for stakeholders such as public health bodies and the food industry to explore further ways to help enable consumers make healthy food choices.
Resumo:
In recent years concerns over litigation and the trend towards close monitoring of academic activity has seen the effective hijacking of research ethics by university managers and bureaucrats. This can effectively curtail cutting edge research as perceived ‘safe’ research strategies are encouraged. However, ethics is about more than research governance. Ultimately, it seeks to avoid harm and to increase benefits to society. Rural development debate is fairly quiet on the question of ethics, leaving guidance to professional bodies. This study draws on empirical research that examined the lives of migrant communities in Northern Ireland. This context of increasingly diverse rural development actors provides a backdrop for the way in which the researcher navigates through ethical issues as they unfold in the field. The analysis seeks to relocate ethics from being an annoying bureaucratic requirement to one where it is inherent to rigorous and professional research and practice. It reveals how attention to professional ethics can contribute to effective, situated and reflexive practice, thus transforming ethics to become an asset to professional researchers.
High-Efficiency Harmonic-Peaking Class-EF Power Amplifiers with Enhanced Maximum Operating Frequency
Resumo:
The recently introduced Class-EF power amplifier (PA) has a peak switch voltage lower than that of the Class-E PA. However, the value of the transistor output capacitance at high frequencies is typically larger than the required Class-EF optimum shunt capacitance. Consequently, soft-switching operation that minimizes power dissipation during off-to-on transition cannot be achieved at high frequencies. Two new Class-EF PA variants with transmission-line load networks, namely, third-harmonic-peaking (THP) and fifth-harmonic-peaking (FHP) Class-EF PAs are proposed in this paper. These permit operation at higher frequencies at no expense to other PA figures of merit. Analytical expressions are derived in order to obtain circuit component values, which satisfy the required Class-EF impedances at fundamental frequency, all even harmonics, and the first few odd harmonics as well as simultaneously providing impedance matching to a 50- Ω load. Furthermore, a novel open-circuit and shorted stub arrangement, which has substantial practical benefits, is proposed to replace the normal quarter-wave line connected at the transistor's drain. Using GaN HEMTs, two PA prototypes were built. Measured peak drain efficiency of 91% and output power of 39.5 dBm were obtained at 2.22 GHz for the THP Class-EF PA. The FHP Class-EF PA delivered output power of 41.9 dBm with 85% drain efficiency at 1.52 GHz.