82 resultados para Lens Tuero, Jesús Angel


Relevância:

20.00% 20.00%

Publicador:

Resumo:

An exploration of the pages of two psychiatric hospital magazines, Speedwell from Holywell Hospital, Antrim, and The Sketch from Downshire Hospital, Downpatrick, reveals the activity filled lives of patients and staff during the 1960s and 1970s. This was a time of great change in mental health care. It was also a time of political turbulence in Northern Ireland. With large in-patient populations, both hospitals had a range of occupational and sporting activities available to patients and staff. The magazines formed part of the effort to promote the ethos of a therapeutic community. While hospital magazines may be viewed as one aspect of an institutional system that allowed people to cut themselves from the wider society, they also provided opportunities for budding writers to express their views on life in a hospital from the service user perspective. As such they offer some valuable insights into the lives of psychiatric patients.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The document draws largely on the results of research carried out by Hugh McNally and Dominic Morris of McNally Morris Architects and Keith McAllister of Queen’s University Belfast between 2012 and 2013. The objective of the study was to obtain a greater understanding of the impact that architecture and the built environment can have on people with autism spectrum disorder (ASD). The investigation into the subject centred on parents of young children with ASD in the belief that they are most likely to have an intimate knowledge of the issues that affect their children and are relatively well positioned to communicate those issues.

The study comprised a number of components.

- Focus Group Discussions with parents of children with ASD
- A Postal Questionnaire completed by parents of children with ASD
- A Comprehensive Desktop study of contemporary research into the relationship between ASD and aspects of the built environment.

Social stories are then used to help illustrate the world of a child with ASD to the reader and identify a series of potential difficulties for the pupil with ASD in a primary school setting. Design considerations and mitigating measures are then proposed for each difficulty.

The intention is that the document will raise awareness of some of the issues affecting primary school children with ASD and generate discourse among those whose task it is to provide an appropriate learning environment for all children. This includes teachers, health professionals, architects, parents, carers, school boards, government bodies and those with ASD themselves.

While this document uses the primary school as a lens through which to view some of the issues associated with ASD, it is the authors’ contention that the school can be seen as a “microcosm” for the wider world and that lessons taken from the learning environment can be applied elsewhere. The authors therefore hope that the document will help raise awareness of the myriad of issues for those with ASD that are embedded in the vast landscape of urban configurations and building types making up the spatial framework of our society.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

We demonstrate that a quasi-crystal array of nanoholes in a metal screen can mimic a function of the lens: one-to-one imaging of a point source located a few tens of wavelengths away from the array to a point on the other side of the array. A displacement of the point source leads to a linear displacement of the image point. Complex structures composed of multiple point sources can be faithfully imaged with resolutions comparable to those of high numerical aperture lenses.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

We studied the process of lens regeneration in the rat following an extracapsular lens extraction preserving the anterior lens capsule and anterior lens epithelium. We assessed clinically the clarity of the newly regenerated lens, evaluated changes in the lens electrical currents following surgery and during the regeneration process and correlated these changes with findings on light microscopy. Protein analysis of the regenerated lens was also undertaken. Experiments were performed in 41 Sprague-Dawley rats, sacrificed at 0, 2, 4 and 8 weeks postoperatively. Our results showed that complete lens regeneration occurred 8 weeks postoperatively only if the anterior epithelium was preserved and the lens capsule was closed surgically. Lens electrical currents, altered following surgery, recovered in parallel with the process of regeneration of the lens. The newly regenerated lens was optically clear and biochemical analysis revealed a pattern of protein expression resembling that observed during lens development. In conclusion, complete lens regeneration occurs in the rat and it is possible that lens electrical signals, together with other cues, may play an important role in this process. © 2009 Elsevier Ltd.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Background/aims - Epiretinal and retrolental proliferation may occur during prolonged use of the novel tamponade agent perfluorohexyloctane (F H ). This study aims to determine whether there is any histological evidence that F H has a role in the formation of these membranes. Methods - Eight epiretinal membranes and three opaque posterior lens capsules were excised from patients in whom F H had been used as a long term retinal tamponade agent. The membranes and capsules were examined employing light microscopic methods, including immunohistochemistry. Results - The epiretinal membranes showed histological features typical of proliferative vitreoretinopathy (PVR) epiretinal membranes, but they also exhibited a dense macrophagic infiltration. In addition, three of the membranes contained multinucleated cells. Macrophages represented up to 30% of the cells present and appeared to contain large intracytoplasmic vacuoles. Similar cells were seen on the back of the posterior lens capsule in one specimen and all three capsules had posterior migration of lens epithelium. Conclusion - The pathological findings are not simply those of PVR. The macrophage infiltration suggests that there may be a biological reaction to F H which could reflect its surmised propensity to emulsify. Further investigations concerning the cellular response to this promising tamponade agent are warranted.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Purpose: The purpose of this study was to evaluate the outcome of patients with healed moderate to severe contact lens-associated corneal infectious ulcers who were re-fit with contact lenses. Methods: We retrospectively studied patients who were fit with contact lenses on our service and who had had moderate to severe corneal infectious ulcers associated with previous contact lens use. Six patients were included in the study. Results: Gas permeable contact lenses were fit in five patients, and a soft contact lens was fit in one patient. Successful fit was achieved in all cases and visual acuities were equal to or better than 20/30 in all patients. No significant complications were observed after a mean follow-up of 23 months (range, 6-45 months). Conclusion: In this small series of patients with a history of moderate to severe contact-lens related infectious keratitis, no complications were observed after contact lenses were refit. Contact lens wear in patients with a history of infectious keratitis may be safe and useful in order to achieve visual rehabilitation.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Purpose: To evaluate the outcome of combined mitomycin-C filtering surgery, phacoemulsification, and foldable intraocular lens (IOL) implantation. Setting: Wills Eye Hospital, Thomas Jefferson University, Philadelphia, Pennsylvania, USA. Methods: This retrospective study evaluated 182 eyes of 174 patients who had combined mitomycin-C trabeculectomy, phacoemulsification, and insertion of a foldable IOL through a 3.5 mm incision. Success of the combined procedure was defined as intraocular pressure (IOP) below 21 mm Hg, with or without medications, and no serious complication. Success rates were calculated using the Kaplan-Meier actuarial method. Results: Mean follow-up was 16.7 months ± 5.4 (SD). The probability of success at 6, 12, 18, and 24 months was 98.3, 95.6, 90.6, and 88.0%, respectively. When compared with preoperativety, visual acuity improved one or more lines in 148 eyes (81.3%) and worsened one or more lines in 15 (8.2%); 111 eyes (61.0%) achieved visual acuity of 20/40 or better. The most frequent complication was posterior capsule opacification requiring capsulotomy, which occurred in 22 cases (12.0%). Conclusion: The 1 year and 2 year IOP control rate of combined mitomycin-C filtering procedures and phacoemulsification in glaucoma patients was high.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

BACKGROUND: Glaucoma is the leading cause of irreversible blindness. Although primary open-angle glaucoma is more common, primary angle-closure glaucoma (PACG) is more likely to result in irreversible blindness. By 2020, 5·3 million people worldwide will be blind because of PACG. The current standard care for PACG is a stepped approach of a combination of laser iridotomy surgery (to open the drainage angle) and medical treatment (to reduce intraocular pressure). If these treatments fail, glaucoma surgery (eg, trabeculectomy) is indicated. It has been proposed that, because the lens of the eye plays a major role in the mechanisms leading to PACG, early clear lens extraction will improve glaucoma control by opening the drainage angle. This procedure might reduce the need for drugs and glaucoma surgery, maintain good visual acuity, and improve quality of life compared with standard care.EAGLE aims to evaluate whether early lens extraction improves patient-reported, clinical outcomes, and cost-effectiveness, compared with standard care.

METHODS/DESIGN: EAGLE is a multicentre pragmatic randomized trial. All people presenting to the recruitment centres in the UK and east Asia with newly diagnosed PACG and who are at least 50 years old are eligible.The primary outcomes are EQ-5D, intraocular pressure, and incremental cost per quality adjusted life year (QALY) gained. Other outcomes are: vision and glaucoma-specific patient-reported outcomes, visual acuity, visual field, angle closure, number of medications, additional surgery (e.g., trabeculectomy), costs to the health services and patients, and adverse events.A single main analysis will be done at the end of the trial, after three years of follow-up. The analysis will be based on all participants as randomized (intention to treat). 400 participants (200 in each group) will be recruited, to have 90% power at 5% significance level to detect a difference in EQ-5D score between the two groups of 0·05, and a mean difference in intraocular pressure of 1·75 mm Hg. The study will have 80% power to detect a difference of 15% in the glaucoma surgery rate.

TRIAL REGISTRATION: ISRCTN44464607.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

This report describes the implantation of a standard posterior chamber intraocular lens (IOL) in a patient with bilateral cataract and anterior megalophthalmos. After extracapsular cataract extraction, the IOL was sutured to the posterior surface of the iris and anterior capsule. Different types of IOLs were used in each eye, and the surgical technique was adapted to the characteristics of the IOL. No complications were noted. Visual rehabilitation was successful. Extracapsular cataract extraction with a posterior chamber IOL sutured to the posterior surface of the iris and anterior capsule is a useful option in patients with anterior megalophthalmos and cataract.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

This rapid response paper examines the claim that Olympic Games hosting can encourage and/or accentuate the adoption of environmental sustainability (ES) policies by the host nation, with London 2012 as a case study. Six indicators that can be used in this examination are identified and subsequently tested in relation to changes brought by austerity/'Big Society' policies. The paper closes by suggesting that although the UK, unlike other hosts, had a relatively good ES standing; however, it appears that this has been significantly downgraded in the event and immediate post-event phases of the Games

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Free space transmission of an on-off modulated sinusoidal signal through a phase conjugating lens (PCL) is theoretically examined using a combined time/frequency domain approach. The on-off keyed (OOK) signal is generated by a dipole antenna located in the far-field zone of the lens. The PCL consists of a dual layer of antenna elements interconnected via phase conjugating circuitry. We demonstrate that electromagnetic interference between antenna elements creates spatially localised areas of good-quality reception and zones where the signal is significantly denigrated by interference. Next, it is shown that destructive interference and packet desynchronisation effects critically depend on bit rate. It is also shown that a circular concave lens can be used to produce high-quality signal reception in a given direction while suppressing signal reception in all other directions. The effect that the bandwidth of the phase conjugating unit has on the transmitted signal properties for the cases of high and low bit rate OOK modulation are studied and a signal quality characterisation scheme is proposed which uses cross-correlation. The results of the study yields understanding of the performance of phase conjugating arrays under OOK modulation. The work suggests a novel approach for realising a secure communication wireless system.

Relevância:

20.00% 20.00%

Publicador:

Resumo:



Email
Print
Request Permissions











A new type of microwave demultiplexer is proposed which combines an arrayed waveguide grating (AWG) and a Rotman lens. The dispersion property of an AWG is employed to produce different phase slope responses for different frequencies, while the Rotman lens routes the frequency components onto different ports. To optimize isolation performance, the design constraints of both the AWG and the Rotman lens are re-examined and new design criteria elaborated. The optimized design is demonstrated of being capable of achieving 15 dB channel isolation over a 25% band range centered at 10 GHz. While a design based on a conventional Rotman lens yields isolation level of around 6 dB over a 9% band range centered at 10GHz.