67 resultados para Leakage.
Resumo:
Retinal vascular leakage, inflammation, and neovascularization (NV) are features of diabetic retinopathy (DR). Fenofibrate, a peroxisome proliferator-activated receptor a (PPARa) agonist, has shown robust protective effects against DR in type 2 diabetic patients, but its effects on DR in type 1 diabetes have not been reported. This study evaluated the efficacy of fenofibrate on DR in type 1 diabetes models and determined if the effect is PPARa dependent. Oral administration of fenofibrate significantly ameliorated retinal vascular leakage and leukostasis in streptozotocin-induced diabetic rats and in Akita mice. Favorable effects on DR were also achieved by intravitreal injection of fenofibrate or another specific PPARa agonist. Fenofibrate also ameliorated retinal NV in the oxygen-induced retinopathy (OIR) model and inhibited tube formation and migration in cultured endothelial cells. Fenofibrate also attenuated overexpression of intercellular adhesion molecule-1, monocyte chemoattractant protein-1, and vascular endothelial growth factor (VEGF) and blocked activation of hypoxia-inducible factor-1 and nuclear factor-?B in the retinas of OIR and diabetic models. Fenofibrate's beneficial effects were blocked by a specific PPARa antagonist. Furthermore, Ppara knockout abolished the fenofibrate-induced downregulation of VEGF and reduction of retinal vascular leakage in DR models. These results demonstrate therapeutic effects of fenofibrate on DR in type 1 diabetes and support the existence of the drug target in ocular tissues and via a PPARa-dependent mechanism.
Resumo:
Although Wnt signaling is known to mediate multiple biological and pathological processes, its association with diabetic retinopathy (DR) has not been established. Here we show that retinal levels and nuclear translocation of beta-catenin, a key effector in the canonical Wnt pathway, were increased in humans with DR and in three DR models. Retinal levels of low-density lipoprotein receptor-related proteins 5 and 6, coreceptors of Wnts, were also elevated in the DR models. The high glucose-induced activation of beta-catenin was attenuated by aminoguanidine, suggesting that oxidative stress is a direct cause for the Wnt pathway activation in diabetes. Indeed, Dickkopf homolog 1, a specific inhibitor of the Wnt pathway, ameliorated retinal inflammation, vascular leakage, and retinal neovascularization in the DR models. Dickkopf homolog 1 also blocked the generation of reactive oxygen species induced by high glucose, suggesting that Wnt signaling contributes to the oxidative stress in diabetes. These observations indicate that the Wnt pathway plays a pathogenic role in DR and represents a novel therapeutic target.
Resumo:
According to a current paradigm cardiovascular diseases can be initiated by exposure of vascular cells to qualitatively modified low-density lipoproteins (LDL). Capillary leakage, an early feature of diabetic retinopathy, results in the exposure of retinal pericytes to modified LDL, including glycated (G-LDL) and heavily oxidized glycated LDL (HOG-LDL). We demonstrate here that modified LDL inhibits the proliferation and survival of cultured human retinal pericytes. Modified LDL also induced DNA fragmentation in bovine retinal pericytes. Overall, HOG-LDL produced a significantly higher extent of cytotoxicity and apoptosis in retinal pericytes. These results indicate that exposure of pericytes to HOG-LDL could be implicated in the development of diabetic retinopathy.
Resumo:
Hyperglycemia may contribute directly to pericyte loss and capillary leakage in early diabetic retinopathy. To elucidate relative contributions of glycation, glycoxidation, sugar autoxidation, osmotic stress and metabolic effects in glucose-mediated capillary damage, we tested the effects of D-glucose, L-glucose, mannitol and the potentially protective effects of aminoguanidine on cultured bovine retinal capillary pericytes and endothelial cells. Media (containing 5 mM D-glucose) were supplemented to increase the concentration of each sugar by 5, 10, or 20 mM. Subconfluent pericytes and endothelial cells were exposed to the supplemented media in the presence or absence of aminoguanidine (1 nM-100 µM) for three days. Cell counts, viability and protein were determined. For both cell types, all three sugars produced concentration-dependent decreases in cell counts and protein content (p
Resumo:
Context. The VLT-FLAMES Tarantula Survey has an extensive view of the copious number of massive stars in the 30 Doradus (30 Dor) star forming region of the Large Magellanic Cloud. These stars play a crucial role in our understanding of the stellar feedback in more distant, unresolved star forming regions. Aims. The first comprehensive census of hot luminous stars in 30 Dor is compiled within a 10 arcmin (150 pc) radius of its central cluster, R136. We investigate the stellar content and spectroscopic completeness of the early type stars. Estimates were made for both the integrated ionising luminosity and stellar wind luminosity. These values were used to re-assess the star formation rate (SFR) of the region and determine the ionising photon escape fraction. Methods. Stars were selected photometrically and combined with the latest spectral classifications. Spectral types were estimated for stars lacking spectroscopy and corrections were made for binary systems, where possible. Stellar calibrations were applied to obtain their physical parameters and wind properties. Their integrated properties were then compared to global observations from ultraviolet (UV) to far-infrared (FIR) imaging as well as the population synthesis code, Starburst99. Results. Our census identified 1145 candidate hot luminous stars within 150 pc of R136 of which >700 were considered to be genuine early type stars and contribute to feedback. We assess the survey to be spectroscopically complete to 85% in the outer regions (>5 pc) but only 35% complete in the region of the R136 cluster, giving a total of 500 hot luminous stars in the census which had spectroscopy. Only 31 were found to be Wolf-Rayet (W-R) or Of/WN stars, but their contribution to the integrated ionising luminosity and wind luminosity was ~ 40% and ~ 50%, respectively. Similarly, stars with M > 100 M (mostly H-rich WN stars) also showed high contributions to the global feedback, ~ 25% in both cases. Such massive stars are not accounted for by the current Starburst99 code, which was found to underestimate the integrated ionising luminosity of R136 by a factor ~ 2 and the wind luminosity by a factor ~ 9. The census inferred a SFR for 30 Dor of 0.073 ± 0.04 M yr . This was generally higher than that obtained from some popular SFR calibrations but still showed good consistency with the far-UV luminosity tracer as well as the combined Hα and mid-infrared tracer, but only after correcting for Hα extinction. The global ionising output was also found to exceed that measured from the associated gas and dust, suggesting that ~6 % of the ionising photons escape the region. Conclusions. When studying the most luminous star forming regions, it is essential to include their most massive stars if one is to determine a reliable energy budget. Photon leakage becomes more likely after including their large contributions to the ionising output. If 30 Dor is typical of other massive star forming regions, estimates of the SFR will be underpredicted if this escape fraction is not accounted for.
Resumo:
Clinical epidemiological studies have revealed relatively weak, yet statistically significant, associations between dyslipidemia/dyslipoproteinemia and diabetic retinopathy (DR). Recent large interventional studies, however, demonstrated an unexpectedly robust efficacy of fenofibrate on the development of DR, possibly independent of plasma lipids. To unify the apparent discrepancies, we hypothesize that plasma lipoproteins play an indirect but important role in DR, contingent on the integrity of the blood-retina-barrier (BRB). In retinas with an intact BRB, plasma lipoproteins may be largely irrelevant; however, important effects become operative after the BRB is impaired in diabetes, leading to lipoprotein extravasation and subsequent modification, hence toxicity to the neighbouring retinal cells. In this hypothesis, BRB leakage is the key, plasma lipoprotein concentrations mainly modulate its consequences, and fenofibrate has intra-retinal actions. This review summarizes our current knowledge of the direct effects and mechanisms of modified lipoproteins on retinal cells and their potential contribution to the pathogenesis of DR.
Resumo:
Non-Volatile Memory (NVM) technology holds promise to replace SRAM and DRAM at various levels of the memory hierarchy. The interest in NVM is motivated by the difficulty faced in scaling DRAM beyond 22 nm and, long-term, lower cost per bit. While offering higher density and negligible static power (leakage and refresh), NVM suffers increased latency and energy per memory access. This paper develops energy and performance models of memory systems and applies them to understand the energy-efficiency of replacing or complementing DRAM with NVM. Our analysis focusses on the application of NVM in main memory. We demonstrate that NVM such as STT-RAM and RRAM is energy-efficient for memory sizes commonly employed in servers and high-end workstations, but PCM is not. Furthermore, the model is well suited to quickly evaluate the impact of changes to the model parameters, which may be achieved through optimization of the memory architecture, and to determine the key parameters that impact system-level energy and performance.
Resumo:
Today's multi-media electronic era is driven by the increasing demand for small multifunctional devices able to support diverse services. Unfortunately, the high levels of transistor integration and performance required by such devices lead to an unprecedented increase of on-chip power that significantly limits the battery lifetime and even poses reliability concerns. Several techniques have been developed to address the power increase, but voltage over-scaling (VOS) is considered to be one of the most effective ones due to the quadratic dependence of voltage on dynamic power consumption. However, VOS may not always be applicable since it increases the delay in all paths of a system and may limit high performance required by today's complex applications. In addition, application of VOS is further complicated since it increases the variations in transistor characteristics imposed by their tiny size which can lead to large delay and leakage variations, making it difficult to meet delay and power budgets. This paper presents a review of various cross-layer design options that can provide solutions for dynamic voltage over-scaling and can potentially assist in meeting the strict power budgets and yield/quality requirements of future systems. © 2011 IEEE.
Resumo:
In this paper, a multi-level wordline driver scheme is presented to improve SRAM read and write stability while lowering power consumption during hold operation. The proposed circuit applies a shaped wordline voltage pulse during read mode and a boosted wordline pulse during write mode. During read, the applied shaped pulse is tuned at nominal voltage for short period of time, whereas for the remaining access time, the wordline voltage is reduced to a lower level. This pulse results in improved read noise margin without any degradation in access time which is explained by examining the dynamic and nonlinear behavior of the SRAM cell. Furthermore, during hold mode, the wordline voltage starts from a negative value and reaches zero voltage, resulting in a lower leakage current compared to conventional SRAM. Our simulations using TSMC 65nm process show that the proposed wordline driver results in 2X improvement in static read noise margin while the write margin is improved by 3X. In addition, the total leakage of the proposed SRAM is reduced by 10% while the total power is improved by 12% in the worst case scenario of a single SRAM cell. The total area penalty is 10% for a 128Kb standard SRAM array.
Resumo:
In this paper, a multi-level wordline driver scheme is presented to improve 6T-SRAM read and write stability. The proposed wordline driver generates a shaped pulse during the read mode and a boosted wordline during the write mode. During read, the shaped pulse is tuned at nominal voltage for a short period of time, whereas for the remaining access time, the wordline voltage is reduced to save the power consumption of the cell. This shaped wordline pulse results in improved read noise margin without any degradation in access time for small wordline load. The improvement is explained by examining the dynamic and nonlinear behavior of the SRAM cell. Furthermore, during the hold mode, for a short time (depending on the size of boosting capacitance), wordline voltage becomes negative and charges up to zero after a specific time that results in a lower leakage current compared to conventional SRAM. The proposed technique results in at least 2× improvement in read noise margin while it improves write margin by 3× for lower supply voltages than 0.7 V. The leakage power for the proposed SRAM is reduced by 2% while the total power is improved by 3% in the worst case scenario for an SRAM array. The main advantage of the proposed wordline driver is the improvement of dynamic noise margin with less than 2.5% penalty in area. TSMC 65 nm technology models are used for simulations.
Resumo:
Electrolytic capacitors are extensively used in power converters but they are bulky, unreliable, and have short lifetimes. This paper proposes a new capacitor-free high step-up dc-dc converter design for renewable energy applications such as photovoltaics (PVs) and fuel cells. The primary side of the converter includes three interleaved inductors, three main switches, and an active clamp circuit. As a result, the input current ripple is greatly reduced, eliminating the necessity for an input capacitor. In addition, zero voltage switching (ZVS) is achieved during switching transitions for all active switches, so that switching losses can be greatly reduced. Furthermore, a three-phase modular structure and six pulse rectifiers are employed to reduce the output voltage ripple. Since magnetic energy stored in the leakage inductance is recovered, the reverse-recovery issue of the diodes is effectively solved. The proposed converter is justified by simulation and experimental tests on a 1-kW prototype.
Resumo:
Purpose: We reviewed the outcome of cuff downsizing with an artificial urinary sphincter for treating recurrent incontinence due to urethral atrophy.
Materials and Methods: We analyzed the records of 17 patients in a 7-year period in whom clinical, radiological and urodynamic evidence of urethral atrophy was treated with cuff downsizing. Cuff downsizing was accomplished by removing the existing cuff and replacing it with a 4 cm. cuff within the established false capsule. Incontinence and satisfaction parameters before and after the procedure were assessed by a validated questionnaire.
Results: Mean patient age was 70 years (range 62 to 79). Average time to urethral atrophy was 31 months (range 5 to 96) after primary sphincter implantation. Mean followup after downsizing was 22 months (range 1 to 64). Cuff downsizing caused a mean decrease of 3.9 to 0.5 pads daily. The number of severe leakage episodes decreased from a mean of 5.4 to 2.1 The mean SEAPI (stress leakage, emptying, anatomy, protection, inhibition) score decreased from 8.2 to 2.4. Patient satisfaction increased from 15% to 80% after cuff downsizing. In 1 patient an infected cuff required complete removal of the device.
Conclusions: Patient satisfaction and continence parameters improved after cuff downsizing. We believe that this technique is a simple and effective method of restoring continence after urethral atrophy.
Resumo:
Objective To prospectively evaluate and quantify the efficacy of cadaveric fascia lata (CFL) as an allograft material in pubovaginal sling placement to treat stress urinary incontinence (SUI).
Patients and methods Thirty-one women with SUI (25 type II and six type III; mean age 63 years, range 40-75) had a CFL pubovaginal sling placed transvaginally. The operative time, blood loss, surgical complications and mean hospital stay were all documented. Before and at 4 months and 1 year after surgery each patient completed a 3-day voiding diary and validated voiding questionnaires (functional inquiry into voiding habits, Urogenital Distress Inventory and Incontinence Impact Questionnaire, including visual analogue scales).
Results The mean (range) operative time was 71 (50-120) min, blood loss 78.7 (20-250) mL and hospital stay 1.2 (1-2) days; there were no surgical complications. Over the mean follow-up of 13.5 months, complete resolution of SUI was reported by 29 (93%) patients. Overactive bladder symptoms were present in 23 (74%) patients before surgery, 21 (68%) at 4 months and two (6%) at 1 year; 80% of patients with low (<15 cmH (2) O) voiding pressures before surgery required self-catheterization afterward, as did 36% at 4 months, but only one (3%) at 1 year. Twenty-four (77%) patients needed to adopt specific postures to facilitate voiding. After surgery there was a significant reduction in daytime frequency, leakage episodes and pad use (P <0.05). The severity of leak and storage symptoms was also significantly less (P <0.002), whilst the severity of obstructive symptoms remained unchanged. Mean subjective levels of improvement were 69% at 4 months and 85% at 1 year, with corresponding objective satisfaction levels of 61% and 69%, respectively. At 1 year, approximate to 80% of the patients said they would undergo the procedure again and/or recommend it to a friend.
Conclusion Placing a pubovaginal sling of CFL allograft is a highly effective, safe surgical approach for resolving SUI, with a short operative time and rapid recovery. Storage symptoms are significantly improved, and subjective improvement and satisfaction rates are high.
Resumo:
Off-design performance now plays a vital role in the design decisions made for automotive turbocharger turbines. Of particular interest is extracting more energy at high pressure ratios and lower rotational speeds. In this region of operation the U/C value will be low and the rotor will experience high values of positive incidence at the inlet. The positive incidence causes flow to separate on the suction surface and produces high blade loading at inlet, which drives tip leakage. A CFD analysis has been carried out on a number of automotive turbines utilizing non-radial fibred blading. To help improve secondary flows yet meet stress requirements a number of designs have been investigated. The inlet blade angle has been modified in a number of ways. Firstly, the blading has been adjusted as to provide a constant back swept angle in the span wise direction. Using the results of the constant back swept blading studies, the back swept blade angle was then varied in the span wise direction. In addition to this, in an attempt to avoid an increase in stress, the effect of varying the leading edge profile of the blade was investigated. It has been seen that off-design performance is improved by implementing back swept blading at the inlet. Varying the inlet angle in the span wise direction provided more freedom for meeting stress requirements and reduces the negative impact on blade performance at the design point. The blade leading edge profile was seen to offer small improvements during off-design operation with minimal effects on stress within the rotor. However, due to the more pointed nature of the leading edge, the rotor was less tolerant to flow misalignment at the design point.
Resumo:
Conventionally, radial turbines have almost exclusively used radially fibred blades. While issues of mechanical integrity are paramount, there may be opportunities for improving turbine efficiency through a 3D blade design without exceeding mechanical limits. Off-design performance and understanding of the secondary flow structures now plays a vital role in the design decisions made for automotive turbocharger turbines. Of particular interest is extracting more energy at high pressure ratios and lower rotational speeds. Operating in this region means the rotor will experience high values of positive incidence at the inlet. A CFD analysis has been carried out on a scaled automotive turbine utilizing a swing vane stator system. To date no open literature exists on the flow structures present in a standard VGT system. Investigations were carried out on a 90 mm diameter rotor with the stator vane at the maximum, minimum and 25% mass flow rate positions. In addition stator vane endwall clearance existed at the hub side. From investigation of the internal flow fields of the baseline rotor, a number of areas that could be optimized in the future with three dimensional blading were identified. The blade loading and tip leakage flow near inlet play a significant role in the flow development further downstream at all stator vane positions. It was found that tip leakage flow and flow separation at off-design conditions could be reduced by employing back swept blading and redistributing the blade loading. This could potentially reduce the extent of the secondary flow structures found in the present study.