114 resultados para Joint angles
Resumo:
Lip separation is one of the primary sources of inlet distortion, which can result in a loss in fan stability. High angles of incidence are one of several critical causes of lip separation. There have been many studies into inlet performance at high incidence, including the resulting distortion levels when lip separation occurs. However, the vast majority of these investigations have been carried out experimentally, with little in the way of computational results for inlet performance at high incidence. The flow topology within an inlet when lip separation has occurred is also not well understood. This work aims to demonstrate a suitable model for the prediction of inlet flows at high incidence using ANSYS CFX, looking at both the performance of the inlet and the separated flow topology within the inlet. The attenuating effect of the fan is also investigated, with particular emphasis on the flow redistribution ahead of the fan. The results show that the model used is suitable for predicting inlet performance in adverse operating conditions, showing good agreement with experimental results. In addition, the attenuation of the distortion by the fan is also captured by the numerical model.
A preliminary Study of the Effects of medio-Lateral Rotation on Stresses in the Artificial Hip Joint
Resumo:
We present observations of the Rossiter–McLaughlin effect for the transiting exoplanets WASP-1b, WASP-24b, WASP-38b and HAT-P-8b, and deduce the orientations of the planetary orbits with respect to the host stars’ rotation axes. The planets WASP-24b, WASP-38b and HAT-P-8b appear to move in prograde orbits and be well aligned, having sky-projected spin-orbit angles consistent with zero: λ=−4°.7 ± 4°.0, 15°+33−43 and Graphic, respectively. The host stars have Teff < 6250 K and conform with the trend of cooler stars having low obliquities. WASP-38b is a massive planet on a moderately long period, eccentric orbit so may be expected to have a misaligned orbit given the high obliquities measured in similar systems. However, we find no evidence for a large spin-orbit angle. By contrast, WASP-1b joins the growing number of misaligned systems and has an almost polar orbit, λ=Graphic. It is neither very massive, eccentric nor orbiting a hot host star, and therefore does not share the properties of many other misaligned systems.
Resumo:
Purpose: This paper reports the findings of the evaluation of the Supporting People Health Pilots programme, which was established to demonstrate the policy links between housing support services and health and social care services by encouraging the development of integrated services. The paper highlights the challenges Method: The evaluation of the six health pilots rested on two main sources of data collection: Quarterly Project Evaluation Reports collected process data as well as reporting progress against aims and objectives. Semi-structured interviews—conducted across all key professional stakeholder groups and agencies and with people who used services—explored their experiences of these new services. Results: The ability of pilots to work across organisational boundaries to achieve their aims and objectives was associated not only with agencies sharing an understanding of the purpose of the joint venture, a history of joint working and clear and efficient governance arrangements but on two other characteristics: the extent and nature of statutory sector participation and, whether or not the service is defined by a history of voluntary sector involvement. In particular the pilots demonstrated how voluntary sector agencies appeared to be less constrained by organisational priorities and professional agenda and more able to respond flexibly to meet the complex needs of individuals. Conclusion and discussion: The pilots demonstrate that integrating services to support people with complex needs works best
Resumo:
Reliable prediction of long-term medical device performance using computer simulation requires consideration of variability in surgical procedure, as well as patient-specific factors. However, even deterministic simulation of long-term failure processes for such devices is time and resource consuming so that including variability can lead to excessive time to achieve useful predictions. This study investigates the use of an accelerated probabilistic framework for predicting the likely performance envelope of a device and applies it to femoral prosthesis loosening in cemented hip arthroplasty.
A creep and fatigue damage failure model for bone cement, in conjunction with an interfacial fatigue model for the implant–cement interface, was used to simulate loosening of a prosthesis within a cement mantle. A deterministic set of trial simulations was used to account for variability of a set of surgical and patient factors, and a response surface method was used to perform and accelerate a Monte Carlo simulation to achieve an estimate of the likely range of prosthesis loosening. The proposed framework was used to conceptually investigate the influence of prosthesis selection and surgical placement on prosthesis migration.
Results demonstrate that the response surface method is capable of dramatically reducing the time to achieve convergence in mean and variance of predicted response variables. A critical requirement for realistic predictions is the size and quality of the initial training dataset used to generate the response surface and further work is required to determine the recommendations for a minimum number of initial trials. Results of this conceptual application predicted that loosening was sensitive to the implant size and femoral width. Furthermore, different rankings of implant performance were predicted when only individual simulations (e.g. an average condition) were used to rank implants, compared with when stochastic simulations were used. In conclusion, the proposed framework provides a viable approach to predicting realistic ranges of loosening behaviour for orthopaedic implants in reduced timeframes compared with conventional Monte Carlo simulations.
Resumo:
This study provides a general diversity analysis for joint complex diversity coding (CDC) and channel coding-based space-time-frequency codeing is provided. The mapping designs from channel coding to CDC are crucial for efficient exploitation of the diversity potential. This study provides and proves a sufficient condition of full diversity construction with joint three-dimensional CDC and channel coding, bit-interleaved coded complex diversity coding and symbol-interleaved coded complex diversity coding. Both non-iterative and iterative detections of joint channel code and CDC transmission are investigated. The proposed minimum mean-square error-based iterative soft decoding achieves the performance of the soft sphere decoding with reduced complexity.
Resumo:
This manuscript describes how motor behaviour researchers who are not at the same time expert roboticists may implement an experimental apparatus, which has the ability to dictate torque fields around a single joint on one limb or single joints on multiple limbs without otherwise interfering with the inherent dynamics of those joints. Such an apparatus expands the exploratory potential of the researcher wherever experimental distinction of factors may necessitate independent control of torque fields around multiple limbs, or the shaping of torque fields of a given joint independently of its plane of motion, or its directional phase within that plane. The apparatus utilizes torque motors. The challenge with torque motors is that they impose added inertia on limbs and thus attenuate joint dynamics. We eliminated this attenuation by establishing an accurate mathematical model of the robotic device using the Box-Jenkins method, and cancelling out its dynamics by employing the inverse of the model as a compensating controller. A direct measure of the remnant inertial torque as experienced by the hand during a 50 s period of wrist oscillations that increased gradually in frequency from 1.0 to 3.8 Hz confirmed that the removal of the inertial effect of the motor was effectively complete.