75 resultados para Inaccuracy Measure
Resumo:
Many international business (IB) studies have used foreign direct investment (FDI) stocks to measure the aggregate value-adding activity of multinational enterprises (MNE) affiliates in host countries. We argue that FDI stocks are a biased measure of that activity, because the degree to which they overestimate or underestimate affiliate activity varies systematically with host-country characteristics. First, most FDI into countries that serve as tax havens generate no actual productive activity; thus FDI stocks in such countries overestimate affiliate activity. Second, FDI stocks do not include locally raised external funds, funds widely used in countries with well-developed financial markets or volatile exchange rates, resulting in an underestimation of affiliate activity in such countries. Finally, the extent to which FDI translates into affiliate activity increases with affiliate labor productivity, so in countries where labor is more productive, FDI stocks also result in an underestimation of affiliate activity. We test these hypotheses by first regressing affiliate value-added and affiliate sales on FDI stocks to calculate a country-specific mismatch, and then by regressing this mismatch on a host country's tax haven status, level of financial market development, exchange rate volatility, and affiliate labor productivity. All hypotheses are supported, implying that FDI stocks are a biased measure of MNE affiliate activity, and hence that the results of FDI-data-based studies of such activity need to be reconsidered. [ABSTRACT FROM AUTHOR]
Resumo:
Diverse parameters, including chaotropicity, can limit the function of cellular systems and thereby determine the extent of Earth's biosphere. Whereas parameters such as temperature, hydrophobicity, pressure, pH, Hofmeister effects, and water activity can be quantified via standard scales of measurement, the chao-/kosmotropic activities of environmentally ubiquitous substances have no widely accepted, universal scale. We developed an assay to determine and quantify chao-/kosmotropicity for 97 chemically diverse substances that can be universally applied to all solutes. This scale is numerically continuous for the solutes assayed (from +361kJkg-1mol-1 for chaotropes to -659kJkg-1mol-1 for kosmotropes) but there are key points that delineate (i) chaotropic from kosmotropic substances (i.e. chaotropes =+4; kosmotropes =-4kJkg-1mol-1); and (ii) chaotropic solutes that are readily water-soluble (log P<1.9) from hydrophobic substances that exert their chaotropic activity, by proxy, from within the hydrophobic domains of macromolecular systems (log P>1.9). Examples of chao-/kosmotropicity values are, for chaotropes: phenol +143, CaCl2 +92.2, MgCl2 +54.0, butanol +37.4, guanidine hydrochloride +31.9, urea +16.6, glycerol [>6.5M] +6.34, ethanol +5.93, fructose +4.56; for kosmotropes: proline -5.76, sucrose -6.92, dimethylsulphoxide (DMSO) -9.72, mannitol -6.69, trehalose -10.6, NaCl -11.0, glycine -14.2, ammonium sulfate -66.9, polyethylene glycol- (PEG-)1000 -126; and for relatively neutral solutes: methanol, +3.12, ethylene glycol +1.66, glucose +1.19, glycerol [<5M] +1.06, maltose -1.43 (kJkg-1mol-1). The data obtained correlate with solute interactions with, and structure-function changes in, enzymes and membranes. We discuss the implications for diverse fields including microbial ecology, biotechnology and astrobiology.
Resumo:
Emission line fluxes from cool stars are widely used to establish an apparent emission measure distribution, EmdApp(Te), between temperatures characteristic of the low transition region and the low corona. The true emission measure distribution, EmdTrue(Te), is determined by the energy balance and geometry adopted and, with a numerical model, can be used to predict EmdApp(Te), to guide further modelling. The scaling laws that exist between coronal parameters arise from the dimensions of the terms in the energy balance equation. Here, analytical approximations to numerical solutions for EmdTrue(Te) are presented, which show how the constants in the coronal scaling laws are determined. The apparent emission measure distributions show a minimum value at some T0 and a maximum at the mean coronal temperature Tc (although in some stars, emission from active regions can contribute). It is shown that, for the energy balance and geometry adopted, the analytical values of the emission measure and electron pressure at T0 and Tc depend on only three parameters: the stellar surface gravity and the values of T0 and Tc. The results are tested against full numerical solutions for e Eri (K2 V) and are applied to Procyon (a CMi, F5 IV/V). The analytical approximations can be used to restrict the required range of full numerical solutions, to check the assumed geometry and to show where the adopted energy balance may not be appropriate. © 2011 The Authors Monthly Notices of the Royal Astronomical Society © 2011 RAS.
Resumo:
The rotavirus (RV) inner capsid protein VP6 is widely used to evaluate immune response during natural infection and in vaccine studies. Recombinant VP6 from the most prevalent circulating rotavirus strains in each subgroup (SG) identified in a birth cohort of children in southern India [SGII (G1P[8]) and SGI (G10P[11])] were produced. The purified proteins were used to measure VP6-specific antibodies in a Dissociation-Enhanced Lanthanide Fluorometric Immunoassay (DELFIA). The ability of the assay to detect a =2 fold rise in IgG level in a panel of serum samples from a longitudinal study was compared to a gold standard virus-capture ELISA. A strong association was observed between the assays (p
Resumo:
The ability to measure acetabular cup orientation accurately during total hip arthroplasty represents a significant challenge. The aim of this research was to develop and evaluate a novel low cost mechanical device for measuring operative acetabular inclination. Cup implantation was simulated in two trials using the novel device: firstly involving surgeons and engineers orientating acetabular cups with sawbone pelves at a range of inclination angles (20°-55° in 5° increments); secondly in a simulated intra-operative scenario with surgeons. Target angles were compared with achieved angles and deviations from desired angles were recorded. In addition, all participants orientated cups under the same conditions using two other techniques: freehand and with a propriatory Mechanical Alignment Guide. In the first trial, the mean errors (deviations) using freehand technique, the mechanical alignment guide and the new device were 5.2° +/- 4.3° (range 0.1-22.0), 3.6° +/- 3.9° (range 0.1°-33.6°) and 0.5° +/- 0.4° (range 0.0-1.9) respectively. In the second trial, the mean error for freehand technique, mechanical alignment guide and the new device were 6.2° +/- 4.2° (range 0.2-18.2), 3.8° +/- 3.3° (range 0.0-19.1) and 0.6° +/- 0.5° (range 0.0-1.8) respectively. The new device has the potential to allow the surgeon to choose and record operative inclination accurately during total hip arthroplasty in the lateral decubitus position.
Resumo:
We show how our recently proposed scheme for the measurement of the micromaser linewidth, which relates the phase diffusion dynamics of the cavity field to the population statistics of probe atoms, can be applied in the presence of trapping states, where the phase diffusion approximation does not strictly hold. This should allow the observation of the peculiar linewidth oscillations versus atomic pumping which are expected in this regime, and whose origin lies in the quantum nature of the cavity field.
Resumo:
We propose a realistic scheme for measuring the micromaser linewidth by monitoring the phase diffusion dynamics of the cavity field. Our strategy consists of exciting an initial coherent state with the same photon number distribution as the micromaser steady-state field, singling out a purely diffusive process in the system dynamics. After the injection of a counterfield, measurements of the population statistics of a probe atom allow us to derive the micromaser linewidth in all ranges of the relevant parameters, establishing experimentally the distinctive features of the micromaser spectrum due to the discreteness of the electromagnetic field.
Resumo:
Background: A previous review showed that high stress increases the risk of occupational injury by three- to five-fold. However, most of the prior studies have relied on short follow-ups. In this prospective cohort study we examined the effect of stress on recorded hospitalised injuries in an 8-year follow-up.
Methods: A total of 16,385 employees of a Finnish forest company responded to the questionnaire. Perceived stress was measured with a validated single-item measure, and analysed in relation recorded hospitalised injuries from 1986 to 2008. We used Cox proportional hazard regression models to examine the prospective associations between work stress, injuries and confounding factors.
Results: Highly stressed participants were approximately 40% more likely to be hospitalised due to injury over the follow-up period than participants with low stress. This association remained significant after adjustment for age, gender, marital status, occupational status, educational level, and physical work environment.
Conclusions: High stress is associated with an increased risk of severe injury.
Resumo:
When applying biometric algorithms to forensic verification, false acceptance and false rejection can mean a failure to identify a criminal, or worse, lead to the prosecution of individuals for crimes they did not commit. It is therefore critical that biometric evaluations be performed as accurately as possible to determine their legitimacy as a forensic tool. This paper argues that, for forensic verification scenarios, traditional performance measures are insufficiently accurate. This inaccuracy occurs because existing verification evaluations implicitly assume that an imposter claiming a false identity would claim a random identity rather than consciously selecting a target to impersonate. In addition to describing this new vulnerability, the paper describes a novel Targeted.. FAR metric that combines the traditional False Acceptance Rate (FAR) measure with a term that indicates how performance degrades with the number of potential targets. The paper includes an evaluation of the effects of targeted impersonation on an existing academic face verification system. This evaluation reveals that even with a relatively small number of targets false acceptance rates can increase significantly, making the analysed biometric systems unreliable.
Resumo:
BACKGROUND: The new generation of activity monitors allow users to upload their data to the internet and review progress. The aim of this study is to validate the Fitbit Zip as a measure of free-living physical activity.
FINDINGS: Participants wore a Fitbit Zip, ActiGraph GT3X accelerometer and a Yamax CW700 pedometer for seven days. Participants were asked their opinion on the utility of the Fitbit Zip. Validity was assessed by comparing the output using Spearman's rank correlation coefficients, Wilcoxon signed rank tests and Bland-Altman plots. 59.5% (25/47) of the cohort were female. There was a high correlation in steps/day between the Fitbit Zip and the two reference devices (r = 0.91, p < 0.001). No statistically significant difference between the Fitbit and Yamax steps/day was observed (Median (IQR) 7477 (3597) vs 6774 (3851); p = 0.11). The Fitbit measured significantly more steps/day than the Actigraph (7477 (3597) vs 6774 (3851); p < 0.001). Bland-Altman plots revealed no systematic differences between the devices.
CONCLUSIONS: Given the high level of correlation and no apparent systematic biases in the Bland Altman plots, the use of Fitbit Zip as a measure of physical activity. However the Fitbit Zip recorded a significantly higher number of steps per day than the Actigraph.