110 resultados para High intensity focused ultrasound


Relevância:

100.00% 100.00%

Publicador:

Resumo:

The interaction of highintensity laser pulses with matter releases instantaneously ultra‐large currents of highly energetic electrons, leading to the generation of highly‐transient, large‐amplitude electric and magnetic fields. We report results of recent experiment in which such charge dynamics have been studied by using proton probing techniques able to provide maps of the electrostatic fields with high spatial and temporal resolution. The dynamics of ponderomotive channelling in underdense plasmas have been studied in this way, as also the processes of Debye sheath formation and MeV ion front expansion at the rear of laser‐irradiated thin metallic foils. An application employing laser‐driven impulsive fields for energy‐selective ion beam focusing is also presented.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Ultrashort, high contrast laser pulses when focused to high intensity and reflected from a steep solid density 'plasma mirror (PM)' contain coherent XUV radiation in the form of high-order harmonics. The emission can either be due to the relativistically driven oscillating PM (ROM) [1] or due to Coherent wake emission (CWE) [2]. Selective control over the mechanisms and the characteristics of these harmonics and understanding the physics is crucial for the development of intense attosecond light sources. © 2013 IEEE.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

We review principally some recent work carried out in Belfast and Heraklion which handles the few-electron dynamics of atomic and molecular systems exposed to high frequency. high intensity laser fields. The design and application of the quantitatively accurate computational methods is discussed. The Belfast work is illustrated by results for double ionization of helium and the hydrogen molecule where in each case the two electrons have been handled in full-dimensionality. The first results for multiphoton, double ionization of a complex atom, namely magnesium demonstrate an important application of the Heraklion approach.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

BACKGROUND: Acute ankle sprains are usually managed functionally, with advice to undertake progressive weight-bearing and walking. Mechanical loading is an important modular of tissue repair; therefore, the clinical effectiveness of walking after ankle sprain may be dose dependent. The intensity, magnitude and duration of load associated with current functional treatments for ankle sprain are unclear.

AIM: To describe physical activity (PA) in the first week after ankle sprain and to compare results with a healthy control group.

METHODS: Participants (16-65 years) with an acute ankle sprain were randomised into two groups (standard or exercise). Both groups were advised to apply ice and compression, and walk within the limits of pain. The exercise group undertook additional therapeutic exercises. PA was measured using an activPAL accelerometer, worn for 7 days after injury. Comparisons were made with a non-injured control group.

RESULTS: The standard group were significantly less active (1.2 ± 0.4 h activity/day; 5621 ± 2294 steps/day) than the exercise (1.7 ± 0 .7 h/day, p=0.04; 7886 ± 3075 steps/day, p=0.03) and non-injured control groups (1.7 ± 0.4 h/day, p=0.02; 8844 ± 2185 steps/day, p=0.002). Also, compared with the non-injured control group, the standard and exercise groups spent less time in moderate (38.3 ± 12.7 min/day vs 14.5 ± 11.4 min/day, p=0.001 and 22.5 ± 15.9 min/day, p=0.003) and high-intensity activity (4.1 ± 6.9 min/day vs 0.1 ± 0.1 min/day, p=0.001 and 0.62 ± 1.0 min/day p=0.005).

CONCLUSION: PA patterns are reduced in the first week after ankle sprain, which is partly ameliorated with addition of therapeutic exercises. This study represents the first step towards developing evidence-based walking prescription after acute ankle sprain.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Laser-driven proton and ion acceleration is an area of increasing research interest given the recent development of short pulse-high intensity lasers. Several groups have reported experiments to understand whether a laser-driven beam can be applied for radiobiological purposes and in each of these, the method to obtain dose and spectral analysis was slightly different. The difficulty with these studies is that the very large instantaneous dose rate is a challenge for commonly used dosimetry techniques, so that other more sophisticated procedures need to be explored. This paper aims to explain a method for obtaining the energetic spectrum and the dose of a laser-driven proton beam irradiating a cell dish used for radiobiology studies. The procedure includes the use of a magnet to have charge and energy separation of the laser-driven beam, Gafchromic films to have information on dose and partially on energy, and a Monte Carlo code to expand the measured data in order to obtain specific details of the proton spectrum on the cells. Two specific correction factors have to be calculated: one to take into account the variation of the dose response of the films as a function of the proton energy and the other to obtain the dose to the cell layer starting from the dose measured on the films. This method, particularly suited to irradiation delivered in a single laser shot, can be applied in any other radiobiological experiment performed with laser-driven proton beams, with the only condition that the initial proton spectrum has to be at least roughly known. The method was tested in an experiment conducted at Queen's University of Belfast using the TARANIS laser, where the mean energy of the protons crossing the cells was between 0.9 and 5 MeV, the instantaneous dose rate was estimated to be close to 10(9) Gy s(-1) and doses between 0.8 and 5 Gy were delivered to the cells in a single laser shot. The combination of the applied corrections modified the initial estimate of dose by up to 40%.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Recently, the use of plasma optics to improve temporal pulse contrast has had a remarkable impact on the field of high- power laser-solid density interaction physics. Opening an avenue to previously unachievable plasma density gradients in the high intensity focus, this advance has enabled researchers to investigate new regimes of harmonic generation and ion acceleration. Until now, however, plasma optics for fundamental laser reflection have been used in the sub-relativistic intensity regime (10(15) - 10(16)Wcm(-2)) showing high reflectivity (similar to 70%) and good focusability. Therefore, the question remains as to whether plasma optics can be used for such applications in the relativistic intensity regime (> 10(18)Wcm(-2)). Previous studies of plasma mirrors (PMs) indicate that, for 40 fs laser pulses, the reflectivity fluctuates by an order of magnitude and that focusability of the beam is lost as the intensity is increased above 5 x 10(16)Wcm(-2). However, these experiments were performed using laser pulses with a contrast ratio of similar to 10(7) to generate the reflecting surface. Here, we present results for PM operation using high contrast laser pulses resulting in a new regime of operation - the high contrast plasma mirror (HCPM). In this regime, pulses with contrast ratio > 10(10) are used to form the PM surface at > 10(19)Wcm(-2), displaying excellent spatial filtering, reflected near- field beam profile of the fundamental beam and reflectivities of 60 +/- 5%. Efficient second harmonic generation is also observed with exceptional beam quality suggesting that this may be a route to achieving the highest focusable harmonic intensities. Plasma optics therefore offer the opportunity to manipulate ultra-intense laser beams both spatially and temporally. They also allow for ultrafast frequency up-shifting without detrimental effects due to group velocity dispersion (GVD) or reduced focusability which frequently occur when nonlinear crystals are used for frequency conversion.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

The possibility of using high-intensity laser-produced plasmas as a source of energetic ions for heavy ion accelerators is addressed. Experiments have shown that neon ions greater than 6 MeV can be produced from gas jet plasmas, and well-collimated proton beams greater than 20 MeV have been produced from high-intensity Laser solid interactions. The proton beams from the back of thin targets appear to be more collimated and reproducible than are high-energy ions generated in the ablated plasma at the front of the target and may be more suitable for ion injection applications. Lead ions have been produced at energies up to 430 MeV.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Nuclear activation has been observed in materials exposed to the ablated plasma generated from high intensity laser-solid interactions (at focused intensities up to 2x10(19) W/cm(2)) and is produced by protons having energies up to 30 MeV. The energy spectrum of the protons is determined from these activation measurements and is found to be consistent with other ion diagnostics. The possible development of this technique for

Relevância:

100.00% 100.00%

Publicador:

Resumo:

We have performed an experiment aimed at measuring self-generated magnetic fields produced in solids by high electron currents following high-intensity and high contrast short-pulse laser irradiation. This was done using longitudinal high resolution proton deflectometry. The experiment was performed at the Titan-JLF laser facility with a high-power short-pulse beam (700 fs, ~ 110 J) split into two beams irradiating two solid targets. One beam is used for the generation of protons and the other beam for the generation of the ultra-high currents of electrons and of the associated magnetic fields. This capability allows us to study the spatio-temporal evolution of the magnetic fields and its dependence on the laser intensity and target material. © Owned by the authors, published by EDP Sciences, 2013.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

We use unique survey data linked to nearly a decade of administrative income support data to examine the relationship between early marijuana use (at age 14 or younger) and young people's educational outcomes. We find evidence that early marijuana use is related to educational penalties that are compounded by high-intensity use and are larger for young people living in families with a history of income support receipt. The relationships between marijuana use and both high school completion and achieving a university entrance score appear to stem from selectivity into the use of marijuana. In contrast, early marijuana use is associated with significantly lower university entrance scores for those who obtain one, and we provide evidence that this effect is unlikely to be driven by selection. Collectively, these findings point to a more nuanced view of the relationship between adolescent marijuana use and educational outcomes than is suggested by the existing literature.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

A detailed knowledge of the physical phenomena underlying the generation and the transport of fast electrons generated in high-intensity laser-matter interactions is of fundamental importance for the fast ignition scheme for inertial confinement fusion.

Here we report on an experiment carried out with the VULCAN Petawatt beam and aimed at investigating the role of collisional return currents in the dynamics of the fast electron beam. To that scope, in the experiment counter-propagating electron beams were generated by double-sided irradiation of layered target foils containing a Ti layer. The experimental results were obtained for different time delays between the two laser beams as well as for single-sided irradiation of the target foils. The main diagnostics consisted of two bent mica crystal spectrometers placed at either side of the target foil. High-resolution X-ray spectra of the Ti emission lines in the range from the Ly alpha to the K alpha line were recorded. In addition, 2D X-ray images with spectral resolution were obtained by means of a novel diagnostic technique, the energy-encoded pin-hole camera, based on the use of a pin-hole array equipped with a CCD detector working in single-photon regime. The spectroscopic measurements suggest a higher target temperature for well-aligned laser beams and a precise timing between the two beams. The experimental results are presented and compared to simulation results.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

BACKGROUND:
Acute ankle sprains are usually managed functionally, with advice to undertake progressive weight-bearing and walking. Mechanical loading is an important modular of tissue repair; therefore, the clinical effectiveness of walking after ankle sprain may be dose dependent. The intensity, magnitude and duration of load associated with current functional treatments for ankle sprain are unclear.
AIM:
To describe physical activity (PA) in the first week after ankle sprain and to compare results with a healthy control group.
METHODS:
Participants (16-65 years) with an acute ankle sprain were randomised into two groups (standard or exercise). Both groups were advised to apply ice and compression, and walk within the limits of pain. The exercise group undertook additional therapeutic exercises. PA was measured using an activPAL accelerometer, worn for 7 days after injury. Comparisons were made with a non-injured control group.
RESULTS:
The standard group were significantly less active (1.2 ± 0.4 h activity/day; 5621 ± 2294 steps/day) than the exercise (1.7 ± 0 .7 h/day, p=0.04; 7886 ± 3075 steps/day, p=0.03) and non-injured control groups (1.7 ± 0.4 h/day, p=0.02; 8844 ± 2185 steps/day, p=0.002). Also, compared with the non-injured control group, the standard and exercise groups spent less time in moderate (38.3 ± 12.7 min/day vs 14.5 ± 11.4 min/day, p=0.001 and 22.5 ± 15.9 min/day, p=0.003) and high-intensity activity (4.1 ± 6.9 min/day vs 0.1 ± 0.1 min/day, p=0.001 and 0.62 ± 1.0 min/day p=0.005).
CONCLUSION:
PA patterns are reduced in the first week after ankle sprain, which is partly ameliorated with addition of therapeutic exercises. This study represents the first step towards developing evidence-based walking prescription after acute ankle sprain.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Digital avionics systems are increasingly under threat from external electromagnetic interference (EMI). The same avionics systems require a thermal cooling mechanism and one method of providing this is to mount an air vent on the body of the aircraft. For the first time, a nacelle-mounted air vent that may expose the flight critical full authority digital engine controller (FADEC) to high intensity radiated fields (HIRF) is examined. The reflection/transmission characteristics of the vent are reported and the current shielding method employed is shown to provide a low shielding level (5 dB at 18 GHz). A new design has been proposed, providing over 100 dB of attenuation at 18 GHz. To the authors' knowledge this is the first time this shielding method has been applied to aircraft air vents.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Objectives: To describe the use of physiotherapy services and alternative therapies by a population of children with moderate to severe cerebral palsy (CP).
Design: Descriptive cross-sectional survey.
Subjects: A total of 212 parents of children aged 4–14 years with moderate to severe CP were identified from the Northern Ireland Cerebral Palsy Register (NICPR) and a random subsample of their paediatric physiotherapists.
Main measures: A standardized description of motor impairment or assessment form; a postal questionnaire to parents and paediatric physiotherapists (to validate parents’ reports of service use).
Response rates: In total, 85% of parent questionnaires were returned and 100% of paediatric physiotherapists responded.
Results: Service use among families was high; on average the families had contact with approximately seven services in a 6-month time interval. The overwhelming majority of children (96%) received physiotherapy during the school term and most (59%) received treatment at least twice a week for 30 min; 43% of children had their physiotherapy discontinued over the summer holidays. Over one-quarter (28%) of families had opted out of the NHS and bought alternatives like conductive education (21%) or private forms of conventional physiotherapy (16%). Children with more severe forms of CP, in special education, particularly at schools for physical disability, were high-intensity users of the physiotherapy service. Despite this, 74% of parents wanted more physiotherapy for their child.
Conclusions and implications: The demand for physiotherapy services is likely to continue given the relatively stable prevalence rate of CP, the proportion of children with disabling CP and the level of parent interest in the service. A number of quality aspects and gaps in the service have been identified.