50 resultados para Hicks
Proton acceleration enhanced by a plasma jet in expanding foils undergoing relativistic transparency
Resumo:
Ion acceleration driven by the interaction of an ultraintense (2 × 1020 W cm-2) laser pulse with an ultrathin ( nm) foil target is experimentally and numerically investigated. Protons accelerated by sheath fields and via laser radiation pressure are angularly separated and identified based on their directionality and signature features (e.g. transverse instabilities) in the measured spatial-intensity distribution. A low divergence, high energy proton component is also detected when the heated target electrons expand and the target becomes relativistically transparent during the interaction. 2D and 3D particle-in-cell simulations indicate that under these conditions a plasma jet is formed at the target rear, supported by a self-generated azimuthal magnetic field, which extends into the expanded layer of sheath-accelerated protons. Electrons trapped within this jet are directly accelerated to super-thermal energies by the portion of the laser pulse transmitted through the target. The resulting streaming of the electrons into the ion layers enhances the energy of protons in the vicinity of the jet. Through the addition of a controlled prepulse, the maximum energy of these protons is demonstrated experimentally and numerically to be sensitive to the picosecond rising edge profile of the laser pulse.
Resumo:
At sufficiently high laser intensities, the rapid heating to relativistic velocities and resulting decompression of plasma electrons in an ultra-thin target foil can result in the target becoming relativistically transparent to the laser light during the interaction. Ion acceleration in this regime is strongly affected by the transition from an opaque to a relativistically transparent plasma. By spatially resolving the laser-accelerated proton beam at near-normal laser incidence and at an incidence angle of 30°, we identify characteristic features both experimentally and in particle-in-cell simulations which are consistent with the onset of three distinct ion acceleration mechanisms: sheath acceleration; radiation pressure acceleration; and transparency-enhanced acceleration. The latter mechanism occurs late in the interaction and is mediated by the formation of a plasma jet extending into the expanding ion population. The effect of laser incident angle on the plasma jet is explored.
Resumo:
PURPOSE: Concerns were raised about the safety of antiplatelet thienopyridine derivatives after a randomized control trial reported increased risks of cancer and cancer deaths in prasugrel users. We investigate whether clopidogrel, a widely used thienopyridine derivative, was associated with increased risk of cancer-specific or all-cause mortality in cancer patients.
METHODS: Colorectal, breast and prostate cancer patients, newly diagnosed from 1998 to 2009, were identified from the National Cancer Data Repository. Cohorts were linked to the UK Clinical Practice Research Datalink, providing prescription records, and to the Office of National Statistics mortality data (up to 2012). Unadjusted and adjusted hazard ratios (HRs) for cancer-specific and all-cause mortality in post-diagnostic clopidogrel users were calculated using time-dependent Cox regression models.
RESULTS: The analysis included 10 359 colorectal, 17 889 breast and 13 155 prostate cancer patients. There was no evidence of an increase in cancer-specific mortality in clopidogrel users with colorectal (HR = 0.98 95% confidence interval (CI) 0.77, 1.24) or prostate cancer (HR = 1.03 95%CI 0.82, 1.28). There was limited evidence of an increase in breast cancer patients (HR = 1.22 95%CI 0.90, 1.65); however, this was attenuated when removing prescriptions in the year prior to death.
CONCLUSIONS: This novel study of large population-based cohorts of colorectal, breast and prostate cancer patients found no evidence of an increased risk of cancer-specific mortality among colorectal, breast and prostate cancer patients using clopidogrel.
Resumo:
BACKGROUND: Preclinical studies have shown that statins, particularly simvastatin, can prevent growth in breast cancer cell lines and animal models. We investigated whether statins used after breast cancer diagnosis reduced the risk of breast cancer-specific, or all-cause, mortality in a large cohort of breast cancer patients.
METHODS: A cohort of 17,880 breast cancer patients, newly diagnosed between 1998 and 2009, was identified from English cancer registries (from the National Cancer Data Repository). This cohort was linked to the UK Clinical Practice Research Datalink, providing prescription records, and to the Office of National Statistics mortality data (up to 2013), identifying 3694 deaths, including 1469 deaths attributable to breast cancer. Unadjusted and adjusted hazard ratios (HRs) for breast cancer-specific, and all-cause, mortality in statin users after breast cancer diagnosis were calculated using time-dependent Cox regression models. Sensitivity analyses were conducted using multiple imputation methods, propensity score methods and a case-control approach.
RESULTS: There was some evidence that statin use after a diagnosis of breast cancer had reduced mortality due to breast cancer and all causes (fully adjusted HR = 0.84 [95% confidence interval = 0.68-1.04] and 0.84 [0.72-0.97], respectively). These associations were more marked for simvastatin 0.79 (0.63-1.00) and 0.81 (0.70-0.95), respectively.
CONCLUSIONS: In this large population-based breast cancer cohort, there was some evidence of reduced mortality in statin users after breast cancer diagnosis. However, these associations were weak in magnitude and were attenuated in some sensitivity analyses.
Resumo:
Channel formation during the propagation of a high-energy (120 J) and long duration (30 ps) laser pulse through an underdense deuterium plasma has been spatially and temporally resolved via means of a proton imaging technique, with intrinsic resolutions of a few micron and a few ps, respectively. Conclusive proof is provided that strong azimuthally symmetric magnetic fields with a strength of around 0.5 MG are created inside the channel, consistent with the generation of a collimated beam of
relativistic electrons. The inferred electron beam characteristics may have implications for the cone-free fast-ignition scheme of inertial confinement fusion