47 resultados para Elliott, Stephen, 1806-1866.
Resumo:
A single-step lateral flow immunoassay was developed and validated to detect okadaic acid (OA) and dinophysis toxins (DTXs), which cause diarrhetic shellfish poisoning. The performance characteristics of the test were investigated, in comparison to reference methods (liquid chromatography tandem mass spectrometry and/or bioassay), using both spiked and naturally contaminated shellfish. A portable reader was used to generate a qualitative result, indicating the absence or presence of OA-group toxins, at concentrations relevant to the maximum permitted level (MPL). Sample homogenates could be screened in 20 min (including extraction and assay time) for the presence of free toxins (OA, DTX1, DTX2). DTX3 detection could be included with the addition of a hydrolysis procedure. No matrix effects were observed from the species evaluated (mussels, scallops, oysters, and clams). Results from naturally contaminated samples (n = 72) indicated no false compliant results and no false noncompliant results at <50% MPL. Thus, the development of a new low-cost but highly effective tool for monitoring a range of important phycotoxins has been demonstrated.
Resumo:
Immunohistochemistry (IHC) is a widely available and highly utilised tool in diagnostic histopathology and is used to guide treatment options as well as provide prognostic information. IHC is subjected to qualitative and subjective assessment, which has been criticised for a lack of stringency, while PCR-based molecular diagnostic validations by comparison are regarded as very rigorous. It is essential that IHC tests are validated through evidence-based procedures. With the move to ISO15189 (2012), not just of the accuracy, specificity and reproducibility of each test need to be determined and managed, but also the degree of uncertainty and the delivery of such tests. The recent update to ISO 15189 (2012) states that it is appropriate to consider the potential uncertainty of measurement of the value obtained in the laboratory and how that may impact on prognostic or predictive thresholds. In order to highlight the problems surrounding IHC validity, we reviewed the measurement of Ki67and p53 in the literature. Both of these biomarkers have been incorporated into clinical care by pathology laboratories worldwide. The variation seen appears excessive even when measuring centrally stained slides from the same cases. We therefore propose in this paper to establish the basis on which IHC laboratories can bring the same level of robust validation seen in the molecular pathology laboratories and the principles applied to all routine IHC tests.