108 resultados para Corneal diseases


Relevância:

20.00% 20.00%

Publicador:

Resumo:

ABSTRACT: BACKGROUND: Chronic diseases are rapidly increasing and are currently the major cause of death and disability worldwide. Patients with chronic diseases experience many challenges including medicine-related problems. However, there is limited information about the home management of medicines among these patients. This study therefore was to determine home medication management practices and associated factors among patients with chronic diseases seeking care in a community pharmacy in Uganda. METHODS: A cross-sectional study was conducted in a community pharmacy in Kampala from June to July 2010. A total of 207 consenting chronic disease patients or caregivers of children with chronic disease were consecutively sampled. The patients were visited at home to evaluate their drug management practices and to check their medical forms for disease types and drugs prescribed. An interviewer-administered questionnaire and an observation checklist were used to collect the data. RESULTS: Overall home medication management was inappropriate for 70% (n = 145) of the participants (95% CI = 63.3-76.2) and was associated with perceived severity of disease (not severe OR =0.40, moderately severe OR = 0.35), duration of disease >5 years (OR = 2.15), and health worker not assessing for response to treatment (OR = 2.53). About 52% (n = 107) had inappropriate storage which was associated with inadequate information about the disease (OR = 2.39) and distance to the health facility >5 kilometres (OR = 2.82). Fifteen percent (n = 31) had no drug administration schedule and this was associated with increasing age (OR = 0.97), inadequate information about the disease (OR = 2.96), and missing last appointment for medical review (OR = 6.55). About 9% (n = 18) had actual medication duplication; 1.4% (n = 3) had expired medicines; while 18.4% (n = 38) had drug hoarding associated with increasing number of prescribers (OR = 1.34) and duration of disease (OR = 2.06). About 51% (n = 105) had multiple prescribers associated with perceiving the disease to be non severe (OR = 0.27), and having more than one chronic disease (OR = 2.37). CONCLUSIONS: Patients with chronic disease have poor home management of medicines. In order to limit the occurrence of poor outcomes of treatment or drug toxicity, health providers need to strengthen the education of patients with chronic disease on how to handle their medicines at home.

Relevância:

20.00% 20.00%

Publicador:

Relevância:

20.00% 20.00%

Publicador:

Resumo:

In recent years there has seen an increased interest in refractive surgery for the correction of presbyopia. This can be attributed to a number of factors such as the increased demand from patients to have perfect vision without the need for glasses, spurred on by the success of high street refractive laser surgery. Also the World Health Organisation (WHO) estimated in 2005 that over a 1.04 billion people worldwide are affected by presbyopia (Holden et al. 2008). This vast number of people is valued as a potential market and is a huge enticement to the ophthalmic industry to try and develop devices and products to treat this condition. Recent advances in technology have renewed interest in the implantation of corneal inlays for surgical treatment of presbyopia. Dexl et al. (2011) suggest that the reason for this is the further development of biomaterial technology, advances in femtosecond laser and the need for a reversible presbyopic treatment.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Purpose: To investigate the temporal course of corneal sensitivity loss & the role of aldose reductase inhibitors (ARI) in an animal model of diabetic ocular complications. Methods: Weanling male S-D rats were randomly grouped to received ad libitum water & diet consisting of Purina (#5001) w/ either: 50% starch (CON,n=15) or 50% D-galactose (GAL,n=30). Half the galactosemic rats (ARI,n=15) received topical 0.25% CT-112 (3x daily, 20µl, Senju Pharmaceutical Co., Japan). Control & remaining half of the galactosemic animals received equivalent doses of saline eyedrops. Rats were restrained w/o medication during sensitivity measurements conducted w/ a Cochet-Bonnet Aesthesiometer mounted on a micromanipulator. The end of the filament (0.012mm dia.), which applied a mean pressure of 0.96 g/mm perpendicular to the corneal surface at center, was in the plane of focus of a slit-lamp biomicroscope. Measurements were conducted by two investigators which were masked to the treatment group. The average blink-responses from 10 consecutive stimuli to each cornea were expressed as a percent. Results: Mean (±SD) baseline corneal sensitivity in all groups were similar (CON 73%±11, GAL 71%±15, ARI 74%±16). Corneal sensitivity in the galactosemic rat was decreased (p

Relevância:

20.00% 20.00%

Publicador:

Resumo:

PURPOSE: To report a new technique to correct tube position in anterior chamber after glaucoma drainage device implantation.

PATIENT AND METHODS: A patient who underwent a glaucoma drainage device implantation was noted to have the tube touching the corneal endothelium. A 10/0 polypropylene suture with double-armed 3-inch long straight needle was placed transcamerally from limbus to limbus, in the superior part of the eye, passing the needle in front of the tube.

RESULTS: The position of the tube in the anterior chamber was corrected with optimal distance from corneal endothelium and iris surface. The position remained satisfactory after 20 months of follow-up.

CONCLUSIONS: The placement of a transcameral suture offers a safe, quick, and minimal invasive intervention for the correction of the position of a glaucoma drainage device tube in the anterior chamber.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

AIM: To estimate the incidence of severe chemical corneal injuries in the UK and describe presenting clinical features and initial management.

METHODS: All patients with severe chemical corneal injury in the UK from December 2005 to November 2006 inclusive were prospectively identified using the British Ophthalmological Surveillance Unit. Reporting ophthalmologists provided information regarding presentation and follow-up.

RESULTS: Twelve cases were identified, giving a minimum estimated incidence in the UK of severe chemical corneal injury of 0.02 per 100,000. 66.7% of injuries were in males of working age, 50% occurred at work, and alkali was causative in 66.7%. Only one patient was wearing eye protection at the time of injury, 75% received immediate irrigation. Six patients required one or more surgical procedures, most commonly amniotic membrane graft. At 6 months' follow-up, the best-corrected visual acuity was 6/12 or better in five patients, and worse than 6/60 in two.

CONCLUSION: The incidence of severe chemical corneal injury in the UK is low. The cases that occur can require extended hospital treatment, with substantial ocular morbidity and visual sequelae. Current enforcement of eye protection in the workplace in the UK has probably contributed to a reduced incidence of severe ocular burns.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Aim - To describe a surgical technique for autologous limbal stem cell transplantation and the outcome of a series of patients with unilateral stem cell deficiency. Methods - A report of six consecutive patients who underwent autologous limbal stem cell transplantation is presented. The primary diagnosis included alkali burn (n = 3), conjunctival intraepithelial neoplasia (CIN) (n = 1), recurrent pterygium (n = 1), and contact lens induced keratopathy (n = 1). The autologous transplanted tissue consisted of peripheral cornea, limbus, and conjunctiva obtained from the contralateral eye. Three of the above patients underwent penetrating keratoplasty in association with autolimbal transplantation. A significant modification to established techniques was the close monitoring of conjunctival epithelial migration in the immediate postoperative period. If conjunctival epithelium threatened to migrate on to the corneal surface, it was mechanically removed at the slit lamp and prevented from crossing the limbus. This was required in three patients. Results - The mean follow up was 18.8 months. The outcome was satisfactory in all cases: a stable corneal surface was restored and there was a substantial improvement in vision and symptoms. One patient had a primary failure of the corneal allograft associated with glaucoma, and 6 months later developed a retinal detachment. No complications were noted in the donor eye with the exception of one patient who developed filamentary keratitis along the edge of the donor site. Conclusion - Autologous limbal transplantation with corneal, limbal, and conjunctival carriers was found to be useful for ocular surface reconstruction, over a mid-term follow up, in patients with unilateral stem cell deficiency. Close monitoring of the migration of conjunctival epithelium in the immediate postoperative period, and preventing it from crossing the limbus, ensured that the corneal surface was re-epithelialised exclusively from epithelial cells derived from the transplanted limbal tissue. This approach should improve the success of this procedure.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

PURPOSE: To determine and compare the corneal biomechanical properties between eyes with primary open angle glaucoma (POAG) and eyes with normal tension glaucoma (NTG). PATIENTS AND METHODS: Prospective cross-sectional study. Consecutive eligible POAG and NTG patients attending the Glaucoma Clinic had assessment of their corneal biomechanical properties-corneal hysteresis (CH) and corneal resistance factor (CRF)-using the Ocular Response Analyzer by an observer masked to the diagnosis. Exclusion criteria included previous intraocular surgery, corneal pathology, inflammatory connective tissue disease, and refraction of 5-dimensional or over. If both eyes were eligible, then the right eye was used for analysis. The main outcome measures were corneal hysteresis and CRF measurements. Data analysis was performed using the t test and general linear model. RESULTS: Eighty-one patients (80 whites) were analyzed. Forty had NTG, whereas 41 had POAG. Thirty-five were females. There was a statistically significant difference in mean CH (NTG 9.6±1.3 mm Hg; POAG 9.0±1.4 mm Hg; P=0.01), but not in mean CRF (NTG 9.9±1.4; POAG 10.8±1.7; P=0.06). The highest recorded Goldmann applanation intraocular pressure (IOP) was statistically significantly associated with lower CH (P=0.01) and higher CRF (P=0.02). CONCLUSIONS: There was a small but statistically significant difference in the mean CH between POAG and NTG (CH was higher in NTG). The highest recorded Goldmann applanation IOP was also statistically significantly correlated with lower CH and higher CRF, suggesting that alterations to the corneal biomechanical properties may occur as a result of chronic raised IOP in POAG. © 2008 by Lippincott Williams & Wilkins.