66 resultados para Augusto Monterroso
Resumo:
Background: In clinical trials the selection of appropriate outcomes is crucial to the assessment of whether one intervention is better than another. Glaucoma is a chronic eye disease and the leading cause of irreversible blindness in the world. A variety of outcomes has been used and reported in glaucoma RCTs.
Objectives: The purpose of this review is to identify different clinical outcome measures used in glaucoma RCTs between January 2006 and March 2012.
Methods: A systematic review was conducted using standard methodology. We searched for RCTs in glaucoma published in English with no restrictions on the population type or size, or applied interventions. All clinical outcomes were included. Patient-reported, pharmacokinetic and economic outcomes were excluded.
Results: The search strategy identified 4288 potentially relevant abstracts. There were 315 publications retrieved, of which 233 RCTs were included. A total of 967 clinical measures were reported. There were large variations in the definitions used to describe different outcomes and their measures. Intraocular pressure (IOP) was the most commonly reported outcome (used in 201 RCTs, 86%) with a total of 422 measures (44%). Amongst the IOPrelated measures, the most commonly used was mean IOP (n=143, 15% of all measures). Safety outcomes were commonly reported, in 145 RCTs (62%) whereas visual field outcomes were utilized in 38 RCTs (16%).
Conclusions: There is a large variability in clinical outcomes used for glaucoma RCTs and in the way each outcome is reported. This lack of standardisation may impair the ability to evaluate the evidence of glaucoma interventions.
Resumo:
In this paper we propose a novel automated glaucoma detection framework for mass-screening that operates on inexpensive retinal cameras. The proposed methodology is based on the assumption that discriminative features for glaucoma diagnosis can be extracted from the optical nerve head structures,
such as the cup-to-disc ratio or the neuro-retinal rim variation. After automatically segmenting the cup and optical disc, these features are feed into a machine learning classifier. Experiments were performed using two different datasets and from the obtained results the proposed technique provides
better performance than approaches based on appearance. A main advantage of our approach is that it only requires a few training samples to provide high accuracy over several different glaucoma stages.
Resumo:
Topic
To compare the accuracy of optical coherence tomography (OCT) with alternative tests for monitoring neovascular age-related macular degeneration (nAMD) and detecting disease activity among eyes previously treated for this condition.
Clinical RelevanceTraditionally, fundus fluorescein angiography (FFA) has been considered the reference standard to detect nAMD activity, but FFA is costly and invasive. Replacement of FFA by OCT can be justified if there is a substantial agreement between tests.
MethodsSystematic review and meta-analysis. The index test was OCT. The comparator tests were visual acuity, clinical evaluation (slit lamp), Amsler chart, color fundus photographs, infrared reflectance, red-free images and blue reflectance, fundus autofluorescence imaging, indocyanine green angiography (ICGA), preferential hyperacuity perimetry, and microperimetry. We searched the following databases: MEDLINE, MEDLINE In-Process, EMBASE, Biosis, Science Citation Index, the Cochrane Library, Database of Abstracts of Reviews of Effects, MEDION, and the Health Technology Assessment database. The last literature search was conducted in March 2013. We used the Quality Assessment of Diagnostic Accuracy Studies 2 (QUADAS-2) to assess risk of bias.
ResultsWe included 8 studies involving more than 400 participants. Seven reported the performance of OCT (3 time-domain [TD] OCT, 3 spectral-domain [SD] OCT, 1 both types) and 1 reported the performance of ICGA in the detection of nAMD activity. We did not find studies directly comparing tests in the same population. The pooled sensitivity and specificity of TD OCT and SD OCT for detecting active nAMD was 85% (95% confidence interval [CI], 72%–93%) and 48% (95% CI, 30%–67%), respectively. One study reported ICGA with sensitivity of 75.9% and specificity of 88.0% for the detection of active nAMD. Half of the studies were considered to have a high risk of bias.
ConclusionsThere is substantial disagreement between OCT and FFA findings in detecting active disease in patients with nAMD who are being monitored. Both methods may be needed to monitor patients comprehensively with nAMD.
Resumo:
BACKGROUND: Age-related macular degeneration is the most common cause of sight impairment in the UK. In neovascular age-related macular degeneration (nAMD), vision worsens rapidly (over weeks) due to abnormal blood vessels developing that leak fluid and blood at the macula.
OBJECTIVES: To determine the optimal role of optical coherence tomography (OCT) in diagnosing people newly presenting with suspected nAMD and monitoring those previously diagnosed with the disease.
DATA SOURCES: Databases searched: MEDLINE (1946 to March 2013), MEDLINE In-Process & Other Non-Indexed Citations (March 2013), EMBASE (1988 to March 2013), Biosciences Information Service (1995 to March 2013), Science Citation Index (1995 to March 2013), The Cochrane Library (Issue 2 2013), Database of Abstracts of Reviews of Effects (inception to March 2013), Medion (inception to March 2013), Health Technology Assessment database (inception to March 2013).
REVIEW METHODS: Types of studies: direct/indirect studies reporting diagnostic outcomes.
INDEX TEST: time domain optical coherence tomography (TD-OCT) or spectral domain optical coherence tomography (SD-OCT).
COMPARATORS: clinical evaluation, visual acuity, Amsler grid, colour fundus photographs, infrared reflectance, red-free images/blue reflectance, fundus autofluorescence imaging, indocyanine green angiography, preferential hyperacuity perimetry, microperimetry. Reference standard: fundus fluorescein angiography (FFA). Risk of bias was assessed using quality assessment of diagnostic accuracy studies, version 2. Meta-analysis models were fitted using hierarchical summary receiver operating characteristic curves. A Markov model was developed (65-year-old cohort, nAMD prevalence 70%), with nine strategies for diagnosis and/or monitoring, and cost-utility analysis conducted. NHS and Personal Social Services perspective was adopted. Costs (2011/12 prices) and quality-adjusted life-years (QALYs) were discounted (3.5%). Deterministic and probabilistic sensitivity analyses were performed.
RESULTS: In pooled estimates of diagnostic studies (all TD-OCT), sensitivity and specificity [95% confidence interval (CI)] was 88% (46% to 98%) and 78% (64% to 88%) respectively. For monitoring, the pooled sensitivity and specificity (95% CI) was 85% (72% to 93%) and 48% (30% to 67%) respectively. The FFA for diagnosis and nurse-technician-led monitoring strategy had the lowest cost (£39,769; QALYs 10.473) and dominated all others except FFA for diagnosis and ophthalmologist-led monitoring (£44,649; QALYs 10.575; incremental cost-effectiveness ratio £47,768). The least costly strategy had a 46.4% probability of being cost-effective at £30,000 willingness-to-pay threshold.
LIMITATIONS: Very few studies provided sufficient information for inclusion in meta-analyses. Only a few studies reported other tests; for some tests no studies were identified. The modelling was hampered by a lack of data on the diagnostic accuracy of strategies involving several tests.
CONCLUSIONS: Based on a small body of evidence of variable quality, OCT had high sensitivity and moderate specificity for diagnosis, and relatively high sensitivity but low specificity for monitoring. Strategies involving OCT alone for diagnosis and/or monitoring were unlikely to be cost-effective. Further research is required on (i) the performance of SD-OCT compared with FFA, especially for monitoring but also for diagnosis; (ii) the performance of strategies involving combinations/sequences of tests, for diagnosis and monitoring; (iii) the likelihood of active and inactive nAMD becoming inactive or active respectively; and (iv) assessment of treatment-associated utility weights (e.g. decrements), through a preference-based study.
STUDY REGISTRATION: This study is registered as PROSPERO CRD42012001930.
FUNDING: The National Institute for Health Research Health Technology Assessment programme.
Resumo:
Purpose:To determine the optimal role of OCT in diagnosing and monitoring nAMD (detecting disease activity and the need for further anti-VEGF treatment).
Methods:Systematic review. Major electronic databases and websites were searched. Studies were included if they reported the diagnostic performance of time domain or spectral domain OCT (or selected other tests) against a reference standard of ophthalmologist-interpreted fluorescein angiography in people with newly suspected or previously diagnosed nAMD. Risk of bias was assessed by two independent investigators using QUADAS-2. Summary receiver operating characteristic (SROC) curves were produced for each test given sufficient data.
Results:3700 titles/abstracts were screened, and 120 (3.2%) were selected for full-text assessment. A total of 22 studies were included (17 on diagnosis, 7 monitoring, and 3 both). From 15 studies reporting OCT data, sensitivity and specificity ranged from 59% to 100% and 27% to 100%, respectively.
Conclusions:The reported diagnostic performance of OCT showed large variability. The methodological quality of most studies was sub-optimal.
Resumo:
Background
Treatments for open-angle glaucoma aim to prevent vision loss through lowering of intraocular pressure, but to our knowledge no placebo-controlled trials have assessed visual function preservation, and the observation periods of previous (unmasked) trials have typically been at least 5 years. We assessed vision preservation in patients given latanoprost compared with those given placebo.
Methods
In this randomised, triple-masked, placebo-controlled trial, we enrolled patients with newly diagnosed open-angle glaucoma at ten UK centres (tertiary referral centres, teaching hospitals, and district general hospitals). Eligible patients were randomly allocated (1:1) with a website-generated randomisation schedule, stratified by centre and with a permuted block design, to receive either latanoprost 0·005% (intervention group) or placebo (control group) eye drops. Drops were administered from identical bottles, once a day, to both eyes. The primary outcome was time to visual field deterioration within 24 months. Analyses were done in all individuals with follow-up data. The Data and Safety Monitoring Committee (DSMC) recommended stopping the trial on Jan 6, 2011 (last patient visit July, 2011), after an interim analysis, and suggested a change in primary outcome from the difference in proportions of patients with incident progression between groups to time to visual field deterioration within 24 months. This trial is registered, number ISRCTN96423140.
Findings
We enrolled 516 individuals between Dec 1, 2006, and March 16, 2010. Baseline mean intraocular pressure was 19·6 mm Hg (SD 4·6) in 258 patients in the latanoprost group and 20·1 mm Hg (4·8) in 258 controls. At 24 months, mean reduction in intraocular pressure was 3·8 mm Hg (4·0) in 231 patients assessed in the latanoprost group and 0·9 mm Hg (3·8) in 230 patients assessed in the placebo group. Visual field preservation was significantly longer in the latanoprost group than in the placebo group: adjusted hazard ratio (HR) 0·44 (95% CI 0·28–0·69; p=0·0003). We noted 18 serious adverse events, none attributable to the study drug.
Interpretation
This is the first randomised placebo-controlled trial to show preservation of the visual field with an intraocular-pressure-lowering drug in patients with open-angle glaucoma. The study design enabled significant differences in vision to be assessed in a relatively short observation period
Resumo:
We propose a feasible experimental scheme to direct measure heat and work in cold atomic setups. The method is based on a recent proposal which shows that work is a positive operator valued measure (POVM). In the present contribution, we demonstrate that the interaction between the atoms and the light polarization of a probe laser allows us to implement such POVM. In this way the work done on or extracted from the atoms after a given process is encoded in the light quadrature that can be measured with a standard homodyne detection. The protocol allows one to verify fluctuation theorems and study properties of the non-unitary dynamics of a given thermodynamic process.