101 resultados para Apple - Storage


Relevância:

20.00% 20.00%

Publicador:

Resumo:

Samples of suspended, floodplain and channel bed sediment have been used to examine downstream changes in ediment-associated contaminant transport and storage in contrasting rivers in Yorkshire, UK. The concentrations of hosphorus, chromium and selected PCBs associated with sediment in the River Aire and its main tributary, the River Calder, which drain an urbanized and industrialized catchment, are considerably higher than those in the relatively unpolluted River Swale, which drains an agricultural catchment. Concentrations of sediment-associated contaminants in the Aire/Calder system increase downstream, reflecting the location of urban and industrial areas in the middle and lower reaches, and the location of point source inputs, such as sewage treatment works. The ontaminant concentrations associated with floodplain and channel bed sediment in the Rivers Aire and Calder are high, particularly in the lower reaches. This, combined with measurements of sediment storage on the floodplain and channel bed, indicate that significant storage of sediment-associated contaminants occurs in the Rivers Aire and Calder.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The manner in which ultrathin films of alumina, deposited at the dielectric-electrode interface, affect the recoverable energy density associated with (BiFeO3)0.6–(SrTiO3)0.4 (BFST) thin film capacitors has been characterised. Approximately 6 nm of alumina on 400 nm of BFST increases the maximum recoverable energy of the system by around 30% from 13 Jcc1 to 17 Jcc1.
Essentially, the alumina acts in the same way as a naturally present parasitic “dead-layer,” distorting the polarisation-field response such that the ultimate polarisation associated with the BFST is pushed to higher values of electric field. The work acts as a proof-of-principle to illustrate how the design of artificial interfacial dielectric “dead-layers” can increase energy densities in simple dielectric capacitors, allowing them to compete more generally with other energy storage technologies.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Two porous metal organic frameworks (MOFs), [M-2(C8H2O6)(H2O)(2)] center dot 8H(2)O (M = Co, Ni), perform exceptionally well for the adsorption, storage, and water-triggered delivery of the biologically important gas nitric oxide. Adsorption and powder X-ray diffraction studies indicate that each coordinatively unsaturated metal atom in the structure coordinates to one NO molecule. All of the stored gas is available for delivery even after the material has been stored for several months. The combination of extremely high adsorption capacity (similar to 7 mmol of NO/g of MOF) and good storage stability is ideal for the preparation of NO storage solids. However, most important is that the entire reservoir of stored gas is recoverable on contact with a simple trigger (moisture). The activity of the NO storage materials is proved in myography experiments showing that the NO-releasing MOFs cause relaxation of porcine arterial tissue.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Gas adsorption experiments have been carried out on a copper benzene tricarboxylate metal-organic framework material, HKUST-1. Hydrogen adsorption at 1 and 10 bar (both 77 K) gives an adsorption capacity of 11.16 mmol H-2 per g of HKUST-1 (22.7 mg g(-1), 2.27 wt %) at 1 bar and 18 mmol per g (36.28 mg g(-1), 3.6 wt %) at 10 bar. Adsorption of D-2 at 1 bar (77 K) is between 1.09 (at 1 bar) and 1.20(at < 100 mbar) times the H-2 values depending on the pressure, agreeing with the theoretical expectations. Gravimetric adsorption measurements of NO on HKUST-1 at 196 K (1 bar) gives a large adsorption capacity of similar to 9 mmol g(-1), which is significantly greater than any other adsorption capacity reported on a porous solid. At 298 K the adsorption capacity at 1 bar is just over 3 mmol g(-1). Infra red experiments show that the NO binds to the empty copper metal sites in HKUST-1. Chemiluminescence and platelet aggregometry experiments indicate that the amount of NO recovered on exposure of the resulting complex to water is enough to be biologically active, completely inhibiting platelet aggregation in platelet rich plasma.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Zeolites exchanged with transition metal cations Co2+, Mn2+, Zn2+ and Cu2+ are capable of storing and delivering a large quantity of nitric oxide in a range of 1.2-2.7 mmolg(-1). The metal ion exchange impacts the pore volumes of zeolite FAU more significantly than LTA. The storage of NO mainly involves coordination of NO to metal cation sites. By exposing zeolites to a moisture atmosphere, the stored nitric oxide can be released. The NO release takes more than 2 hours for the NO concentration decreasing below similar to 5ppb in outlet gas. Its release rate can be controlled by tailoring zeolite frameworks and optimising release conditions.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Hydrogen is expected to play an important role in future transportation as a promising alternative clean energy source to carbon-based fuels. One of the key challenges to commercialize hydrogen energy is to develop appropriate onboard hydrogen storage systems, capable of charging and discharging large quantities of hydrogen with fast enough kinetics to meet commercial requirements. Metal organic framework (MOF) is a new type of inorganic and organic hybrid nanoporous particulate materials. Its diverse networks can enhance hydrogen storage through tuning the structure and property of MOFs. The MOF materials so far developed adsorb hydrogen through weak dispersion interactions, which allow significant quantity of hydrogen to be stored at cryogenic temperatures with fast kinetics. Novel MOFs are being developed to strengthen the interactions between hydrogen and MOFs in order to store hydrogen under ambient conditions. This review surveys the development of such candidate materials, their performance and future research needs. (C) 2009 Chinese Society of Particuology and Institute of Process Engineering, Chinese Academy of Sciences. Published by Elsevier B.V. All rights reserved.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Copper containing MCM-41 materials can be used to both store gaseous nitric oxide and to catalytically produce nitric oxide from nitrite. The active species for the reaction is copper (I). Addition of cysteine to the solution in contact with the material has different effects depending on how much Cu(I) is present. This is a new method of extending the lifetime of gas delivery from a gas storage material.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Nitric oxide can be stored in and produced from zeolites in a simultaneous and cooperative process

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Reagent pre-storage in a microfluidic chip can enhance operator convenience, simplify the system design, reduce the cost of storage and shipment, and avoid the risk of cross-contamination. Although dry reagents have long been used in lateral flow immunoassays, they have rarely been used for nucleic acid-based point-of-care (POC) assays due to the lack of reliable techniques to dehydrate and store fragile molecules involved in the reaction. In this study, we describe a simple and efficient method for prolonged on-chip storage of PCR reagents. The method is based on gelification of all reagents required for PCR as a ready-to-use product. The approach was successfully implemented in a lab-on-a-foil system, and the gelification process was automated for mass production. Integration of reagents on-chip by gelification greatly facilitated the development of easy-to-use lab-on-a-chip (LOC) devices for fast and cost-effective POC analysis.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

In this study, we describe a simple and efficient method for on-chip storage of reagents for point-of-care (POC) diagnostics. The method is based on gelification of all reagents required for on-chip PCR-based diagnostics as a ready-to-use product. The result reported here is a key step towards the development of a ready and easy to use fully integrated Lab-on-a-chip (LOC) system for fast, cost-effective and efficient POC diagnostics analysis.