65 resultados para 860[83].09


Relevância:

20.00% 20.00%

Publicador:

Resumo:

Background: Studies investigating the association between glycated hemoglobin (HbA) level and mortality risk in diabetic patients receiving hemodialysis have shown conflicting results. 
Study Design: We conducted a systematic review and meta-analysis using MEDLINE, EMBASE, Web of Science, and the Cochrane Library. 
Setting & Population: Diabetic patients on maintenance hemodialysis therapy. 
Selection Criteria for Studies: Observational studies or randomized controlled trials investigating the association between HbA values and mortality risk. Study authors were asked to provide anonymized individual patient data or reanalyze results according to a standard template. 
Predictor: Single measurement or mean HbA values. Mean HbA values were calculated using all individual-patient HbA values during the follow-up period of contributing studies. 
Outcome: HR for mortality risk. 
Results: 10 studies (83,684 participants) were included: 9 observational studies and one secondary analysis of a randomized trial. After adjustment for confounders, patients with baseline HbA levels =8.5% (=69 mmol/mol) had increased mortality (7 studies; HR, 1.14; 95% CI, 1.09-1.19) compared with patients with HbA levels of 6.5%-7.4% (48-57 mmol/mol). Likewise, patients with a mean HbA value =8.5% also had a higher adjusted risk of mortality (6 studies; HR,1.29; 95% CI, 1.23-1.35). There was a small but nonsignificant increase in mortality associated with mean HbA levels =5.4% (=36 mmol/mol; 6 studies; HR, 1.09; 95% CI, 0.89-1.34). Sensitivity analyses in incident (=90 days of hemodialysis) and prevalent patients (>90 days of hemodialysis) showed a similar pattern. In incident patients, mean HbA levels =5.4% also were associated with increased mortality risk (4 studies; HR, 1.29; 95% CI, 1.23-1.35). 
Limitations: Observational study data and inability to adjust for diabetes type in all studies. 
Conclusions: Despite concerns about the utility of HbA measurement in hemodialysis patients, high levels (=8.5%) are associated with increased mortality risk. Very low HbA levels (=5.4%) also may be associated with increased mortality risk. 

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The equiprobability bias is a tendency for individuals to think of probabilistic events as 'equiprobable' by nature, and to judge outcomes that occur with different probabilities as equally likely. The equiprobability bias has been repeatedly found to be related to formal education in statistics, and it is claimed to be based on a misunderstanding of the concept of randomness.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Neonatal pain-related stress is associated with elevated salivary cortisol levels to age 18 months in children born very preterm, compared to full-term, suggesting early programming effects. Importantly, interactions between immune/inflammatory and neuroendocrine systems may underlie programming effects. We examined whether cortisol changes persist to school age, and if common genetic variants in the promoter region of the NFKBIA gene involved in regulation of immune and inflammatory responses, modify the association between early experience and later life stress as indexed by hair cortisol levels, which provide an integrated index of endogenous HPA axis activity. Cortisol was assayed in hair samples from 128 children (83 born preterm =32 weeks gestation and 45 born full-term) without major sensory, motor or cognitive impairments at age 7 years. We found that hair cortisol levels were lower in preterm compared to term-born children. Downregulation of the HPA axis in preterm children without major impairment, seen years after neonatal stress terminated, suggests persistent alteration of stress system programming. Importantly, the etiology was gender-specific such that in preterm boys but not girls, specifically those with the minor allele for NFKBIA rs2233409, lower hair cortisol was associated with greater neonatal pain (number of skin-breaking procedures from birth to term), independent of medical confounders. Moreover, the minor allele (CT or TT) of NFKBIA rs2233409 was associated with higher secretion of inflammatory cytokines, supporting the hypothesis that neonatal pain-related stress may act as a proinflammatory stimulus that induces long-term immune cell activation. These findings are the first evidence that a long-term association between early pain-related stress and cortisol may be mediated by a genetic variants that regulate the activity of NF-?B, suggesting possible involvement of stress/inflammatory mechanisms in HPA programming in boys born very preterm. © 2013 Grunau et al.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The recognition of microbial pathogens by the innate immune system involves Toll-like receptors (TLRs), which recognize pathogen-associated molecular patterns. Different TLRs recognize different pathogen-associated molecular patterns, with TLR-4 mediating the response to lipopolysaccharide from Gram-negative bacteria. All TLRs have a Toll/IL-1 receptor (TIR) domain, which is responsible for signal transduction. MyD88 is one such protein that contains a TIR domain. It acts as an adapter, being involved in TLR-2, TLR-4 and TLR-9 signalling; however, our understanding of how TLR-4 signals is incomplete. Here we describe a protein, Mal (MyD88-adapter-like), which joins MyD88 as a cytoplasmic TIR-domain-containing protein in the human genome. Mal activates NF-kappaB, Jun amino-terminal kinase and extracellular signal-regulated kinase-1 and -2. Mal can form homodimers and can also form heterodimers with MyD88. Activation of NF-kappaB by Mal requires IRAK-2, but not IRAK, whereas MyD88 requires both IRAKs. Mal associates with IRAK-2 by means of its TIR domain. A dominant negative form of Mal inhibits NF-kappaB, which is activated by TLR-4 or lipopolysaccharide, but it does not inhibit NF-kappaB activation by IL-1RI or IL-18R. Mal associates with TLR-4. Mal is therefore an adapter in TLR-4 signal transduction.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

This study aims to evaluate the use of Varian radiotherapy dynamic treatment log (DynaLog) files to verify IMRT plan delivery as part of a routine quality assurance procedure. Delivery accuracy in terms of machine performance was quantified by multileaf collimator (MLC) position errors and fluence delivery accuracy for patients receiving intensity modulated radiation therapy (IMRT) treatment. The relationship between machine performance and plan complexity, quantified by the modulation complexity score (MCS) was also investigated. Actual MLC positions and delivered fraction of monitor units (MU), recorded every 50 ms during IMRT delivery, were extracted from the DynaLog files. The planned MLC positions and fractional MU were taken from the record and verify system MLC control file. Planned and delivered beam data were compared to determine leaf position errors with and without the overshoot effect. Analysis was also performed on planned and actual fluence maps reconstructed from the MLC control file and delivered treatment log files respectively. This analysis was performed for all treatment fractions for 5 prostate, 5 prostate and pelvic node (PPN) and 5 head and neck (H&N) IMRT plans, totalling 82 IMRT fields in ∼5500 DynaLog files. The root mean square (RMS) leaf position errors without the overshoot effect were 0.09, 0.26, 0.19 mm for the prostate, PPN and H&N plans respectively, which increased to 0.30, 0.39 and 0.30 mm when the overshoot effect was considered. Average errors were not affected by the overshoot effect and were 0.05, 0.13 and 0.17 mm for prostate, PPN and H&N plans respectively. The percentage of pixels passing fluence map gamma analysis at 3%/3 mm was 99.94 ± 0.25%, which reduced to 91.62 ± 11.39% at 1%/1 mm criterion. Leaf position errors, but not gamma passing rate, were directly related to plan complexity as determined by the MCS. Site specific confidence intervals for average leaf position errors were set at -0.03-0.12 mm for prostate and -0.02-0.28 mm for more complex PPN and H&N plans. For all treatment sites confidence intervals for RMS errors with the overshoot was set at 0-0.50 mm and for the percentage of pixels passing a gamma analysis at 1%/1 mm a confidence interval of 68.83% was set also for all treatment sites. This work demonstrates the successful implementation of treatment log files to validate IMRT deliveries and how dynamic log files can diagnose delivery errors not possible with phantom based QC. Machine performance was found to be directly related to plan complexity but this is not the dominant determinant of delivery accuracy.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The primary purpose of the BASE Project was to establish how to help individuals with Autism Spectrum Disorder out of poverty by promoting social inclusion. In order to achieve this, a range of methodologies were utilised that aimed to provide a baseline against which the effect of the Autism Act (NI) 2011 and the associated Autism Strategy (2013-2020) and Action Plans can be measured. The BASE Project is reported in 5 volumes. Volume 2 reports on the analysis of the autism module of the Northern Ireland Life and Times (NILT) Survey that assessed public awareness, attitudes, knowledge, and projected behaviours with regard to individuals with ASD (all primary data and technical reports are available at www.ark.ac.uk/nilt/).

The NILT (2012) survey first ever autism module (n=1204) offered a baseline against which the impact of new autism legislation, policies, and strategies can be measured. Key findings:

• 82% awareness: Most people in Northern Ireland are aware of autism (n=989).
• 50% of all participants knew someone with autism personally (n=606).

Of those who were aware of autism:
• 19% had a close family member with autism (n=186), and/or a friends/acquaintance (n=296), and/or a work colleague (n=79) with autism.
• Autism awareness was particularly low for those from ethnic minorities and those with no internet access.
• Awareness of autism specific legislation was low (20%).
• Good levels of knowledge about autism strengths and challenges, slight tendency to overestimate the occurrence of special talents.
• Prevalence of autism was underestimated (62% thought autism was much less prevalent than official figures or did not know).
• Fairly accurate perception about causes of autism, i.e., not caused by poor parenting (84%).
• Strong support for evidence-based behavioural interventions (77%), but confusion about interventions that are not evidence-based (64%).
• Strong positive attitudes towards children and adults in social, educational and employment settings.
• Autism not viewed as necessarily ‘lifelong’ (58%); support for independent living (78%), e.g., driving a car (83%).
• More business for employers who employ people with autism (12%).
• Strong support for families caring rather than residential care (64%).
• Confusion about service responsibility: education (26%) health (33%) or both (28%).

Given increasing prevalence rates of ASD it is important that the general population is aware of autism and able to respond responsibly to the associated strengths and challenges. The results of the NILT (2012) first ever autism module show that the general public was well aware of autism, had positive attitudes, and was relatively knowledgeable about the issues faced by individuals and families affected directly. However, there was a lack of clarity about responsibility for effective service delivery. The NILT results show that a shift in focus is necessary from ‘awareness raising campaigns’ to an approach that delivers clarity with regard to intervention and accountability.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Effectiveness of brief/minimal contact self-activation interventions that encourage participation in physical activity (PA) for chronic low back pain (CLBP >12 weeks) is unproven. The primary objective of this assessor-blinded randomized controlled trial was to investigate the difference between an individualized walking programme (WP), group exercise class (EC), and usual physiotherapy (UP, control) in mean change in functional disability at 6 months. A sample of 246 participants with CLBP aged 18 to 65 years (79 men and 167 women; mean age ± SD: 45.4 ± 11.4 years) were recruited from 5 outpatient physiotherapy departments in Dublin, Ireland. Consenting participants completed self-report measures of functional disability, pain, quality of life, psychosocial beliefs, and PA were randomly allocated to the WP (n = 82), EC (n = 83), or UP (n = 81) and followed up at 3 (81%; n = 200), 6 (80.1%; n = 197), and 12 months (76.4%; n = 188). Cost diaries were completed at all follow-ups. An intention-to-treat analysis using a mixed between-within repeated-measures analysis of covariance found significant improvements over time on the Oswestry Disability Index (Primary Outcome), the Numerical Rating Scale, Fear Avoidance-PA scale, and the EuroQol EQ-5D-3L Weighted Health Index (P < 0.05), but no significant between-group differences and small between-group effect sizes (WP: mean difference at 6 months, 6.89 Oswestry Disability Index points, 95% confidence interval [CI] -3.64 to -10.15; EC: -5.91, CI: -2.68 to -9.15; UP: -5.09, CI: -1.93 to -8.24). The WP had the lowest mean costs and the highest level of adherence. Supervised walking provides an effective alternative to current forms of CLBP management.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Background: Preclinical evidence from lung cancer cell lines and animal models suggest that statins could have anticancer properties. We investigated whether statin users had reduced risk of cancer-specific mortality in a population based cohort of lung cancer patients.
Methods: Newly diagnosed lung cancer patients, from 1998 to 2009, were identified from English cancer registry data and linked to the UK Clinical Practice Research Datalink, providing prescription records, and to Office of National Statistics mortality data up to 2012. Cox regression models were used to calculate hazard ratios (HR) for cancer-specific mortality and 95% confidence intervals (CIs) by statin use before and after diagnosis and to adjust these HRs for potential confounders.
Results: In 3,638 lung cancer patients, there was some evidence that statin use after diagnosis was associated with reduced lung cancer-specific mortality (adjusted HR=0.89, 95% CI 0.78, 1.02; P=0.09). Associations were more marked after 12 prescriptions (adjusted HR=0.81, 95% CI 0.67, 0.98; P=0.03) and when lipophilic statins were investigated (adjusted HR=0.81, 95% CI 0.70, 0.94; P=0.01) but were attenuated in some sensitivity analyses. Furthermore, in 11,051 lung cancer patients, statin use before diagnosis was associated with reduced lung cancer-specific mortality (adjusted HR=0.88, 95% CI, 0.83, 0.93; P<0.001).
Conclusions: There was some evidence that lung cancer patients who used statins, and particularly simvastatin, had reduced rates of cancer-specific mortality.
 Impact: These findings should first be confirmed in observational studies, but provide some support for conducting randomized controlled trials of simvastatin as adjuvant cancer therapy in lung cancer patients.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The use of anodic stripping voltammetry (ASV)has been proven in the past to be a precise and sensitive analytical method with an excellent limit of detection. Electrochemical sensors could help to avoid expensive and time consuming procedures as sample taking and storage and provide a both sensitive and reliable method for the direct monitoring of heavy metals in the aquatic environment. Solid electrodes which have been used in this work, were produced using previously developed methods. Commercially available and newly designed, screen printed carbon and gold plated working electrodes (WE) were compared. Good results were achieved with the screen printed and plated electrodes under conditions optimized for each electrode material. The electrode stability, reproducibility of single measurements and the limit of detection obtained for Pb were satisfactory (3*10-6mol/l on screen printed carbon WEs after 60 s of deposition and 6*10-6 mol/l on gold plated WEs after 5 min of deposition). Complete 3-electrode-sets (counter, reference and working electrode) were screen printed on different substrates (glass, polycarbonate and alumina). Also here, both carbon and gold were used as WE. Using 3-electrode-sets with a gold plated WE on glass was a limit of detection of 7*10-7 mol/l was achieved after only 60 s of deposition.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The Consideration of Future Consequences construct has been found to relate meaningfully to several positive outcomes in temporal research. Researchers have proposed 1-factor, 2-factor, and bifactor solutions to the Consideration of Future Consequences Scale (CFCS). Using 313 British University undergraduates, we tested four competing models: (a) a 12-item unidimensional model, (b) a model fitted for two uncorrelated factors (CFC-Immediate and CFC-Future), (c) a model fitted for two correlated factors (CFC-I and CFC-F), and (d) a bifactor model. Results supported the bifactor model, suggesting that the two hypothesized factors are better understood as grouping factors. Accordingly, the present study supports the CFCS as a unidimensional global future orientation measure. These results have important implications for the study of future orientation using the CFCS. Researchers using the CFCS are encouraged to examine a bifactor solution for the scores.