51 resultados para Úlcera de extremidad inferior
Resumo:
β -type Ti-alloy is a promising biomedical implant material as it has a low Young’s modulus but is also known to have inferior surface hardness. Various surface treatments can be applied to enhance the surface hardness. Physical vapour deposition (PVD) and chemical vapour deposition (CVD) are two examples of this but these techniques have limitations such as poor interfacial adhesion and high distortion. Laser surface treatment is a relatively new surface modification method to enhance the surface hardness but its application is still not accepted by the industry. The major problem of this process involves surface melting which results in higher surface roughness after the laser surface treatment. This paper will report the results achieved by a 100 W CW fiber laser for laser surface treatment without the surface being melted. Laser processing parameters were carefully selected so that the surface could be treated without surface melting and thus the surface finish of the component could be maintained. The surface and microstructural characteristics of the treated samples were examined using X-ray diffractometry (XRD), optical microscopy (OM), 3-D surface profile & contact angle measurements and nano-indentation test.
Resumo:
OBJECTIVE: Over several decades, there has been an increase in the number of elderly patients requiring hemodialysis. These older patients typically have an increased incidence of comorbidities including diabetes, hypertension, and peripheral vascular disease. We undertook a systematic review of the current literature to assess outcomes of arteriovenous fistula (AVF) formation in the elderly and to compare the results of radiocephalic AVFs vs brachiocephalic AVFs in older patients.
METHODS: A literature search was performed using MEDLINE, Embase, PubMed, and the Cochrane Library. All retrieved articles published before December 31, 2014 (and in English) primarily describing the creation of hemodialysis vascular access for elderly patients were considered for inclusion. We report pooled AVF patency rates and a comparison of radiocephalic vs brachiocephalic AVF patency rates using odds ratios (ORs).
RESULTS: Of 199 relevant articles reviewed, 15 were deemed eligible for the review. The pooled 12-month primary and secondary AVF patency rates were 53.6% (95% confidence interval [CI], 47.3-59.9) and 71.6% (95% CI, 59.2-82.7), respectively. Comparison of radiocephalic vs brachiocephalic AVF patency rates demonstrated that radiocephalic AVFs have inferior primary (OR, 0.72; 95% CI, 0.55-0.93; P = .01) and secondary (OR, 0.76; 95% CI, 0.58-1.00; P = .05) patency rates.
CONCLUSIONS: This meta-analysis confirms that adequate 12-month primary and secondary AVF patency rates can be achieved in elderly patients. Brachiocephalic AVFs have both superior primary and secondary patency rates at 12 months compared with radiocephalic AVFs. These important data can inform clinicians' and patients' decision-making about suitability of attempting AVF formation in older persons.
Resumo:
Milk in its natural form has a high food value, since it is comprised of a wide variety of nutrients which are essential for proper growth and maintenance of the human body. In recent decades, there has been an upsurge in milk consumption worldwide, especially in developing countries, and it is now forming a significant part of the diet for a high proportion of the global population. As a result of the increased demand, in addition to the growth in competition in the dairy market and the increasing complexity of the supply chain, some unscrupulous producers are indulging in milk fraud. This malpractice has become a common problem in the developing countries, which lack strict vigilance by food safety authorities. Milk is often subjected to fraud (by means of adulteration) for financial gain, but it can also be adulterated due to ill-informed attempts to improve hygiene conditions. Water is the most common adulterant used, which decreases the nutritional value of milk. If the water is contaminated, for example, with chemicals or pathogens, this poses a serious health risk for consumers. To the diluted milk, inferior cheaper materials may be added such as reconstituted milk powder, urea, and cane sugar, even more hazardous chemicals including melamine, formalin, caustic soda, and detergents. These additions have the potential to cause serious health-related problems. This review aims to investigate the impacts of milk fraud on nutrition and food safety, and it points out the potential adverse human health effects associated with the consumption of adulterated milk.
Resumo:
The relatively high elastic modulus coupled with the presence of toxic vanadium (V) in Ti6Al4 V alloy has long been a concern in orthopaedic applications. To solve the problem, a variety of non-toxic and low modulus beta-titanium (beta-Ti) alloys have been developed. Among the beta-Ti alloy family, the quaternary Ti-Nb-Zr-Ta (TNZT) alloys have received the highest attention as a promising replacement for Ti6Al4 V due to their lower elastic modulus and outstanding long term stability against corrosion in biological environments. However, the inferior wear resistance of TNZT is still a problem that must be resolved before commercialising in the orthopaedic market. In this work, a newly-developed laser surface treatment technique was employed to improve the surface properties of Ti-35.3Nb-7.3Zr-5.7Ta alloy. The surface structure and composition of the laser-treated TNZT surface were examined by grazing incidence x-ray diffraction (GI-XRD) and x-ray photoelectron spectroscopy (XPS). The wear and corrosion resistance were evaluated by pin-on-plate sliding test and anodic polarisation test in Hanks’ solution. The experimental results were compared with the untreated (or base) TNZT material. The research findings showed that the laser surface treatment technique reported in this work can effectively improve the wear and corrosion resistance of TNZT.
Resumo:
PURPOSE:
To determine the test-retest variability in perimetric, optic disc, and macular thickness parameters in a cohort of treated patients with established glaucoma.
PATIENTS AND METHODS:
In this cohort study, the authors analyzed the imaging studies and visual field tests at the baseline and 6-month visits of 162 eyes of 162 participant in the Glaucoma Imaging Longitudinal Study (GILS). They assessed the difference, expressed as the standard error of measurement, of Humphrey field analyzer II (HFA) Swedish Interactive Threshold Algorithm fast, Heidelberg retinal tomograph (HRT) II, and retinal thickness analyzer (RTA) parameters between the two visits and assumed that this difference was due to measurement variability, not pathologic change. A statistically significant change was defined as twice the standard error of measurement.
RESULTS:
In this cohort of treated glaucoma patients, it was found that statistically significant changes were 3.2 dB for mean deviation (MD), 2.2 for pattern standard deviation (PSD), 0.12 for cup shape measure, 0.26 mm for rim area, and 32.8 microm and 31.8 microm for superior and inferior macular thickness, respectively. On the basis of these values, it was estimated that the number of potential progression events detectable in this cohort by the parameters of MD, PSD, cup shape measure, rim area, superior macular thickness, and inferior macular thickness was 7.5, 6.0, 2.3, 5.7, 3.1, and 3.4, respectively.
CONCLUSIONS:
The variability of the measurements of MD, PSD, and rim area, relative to the range of possible values, is less than the variability of cup shape measure or macular thickness measurements. Therefore, the former measurements may be more useful global measurements for assessing progressive glaucoma damage.
Resumo:
Beta-type Ti-alloy is a promising biomedical implant material as it has a low Young’s modulus and is also known to have inferior surface hardness. Various surface treatments can be applied to enhance the surface hardness. Physical vapor deposition and chemical vapor deposition are two examples of this but these techniques have limitations such as poor interfacial adhesion and high distortion. Laser surface treatment is a relatively new surface modification method to enhance the surface hardness but its application is still not accepted by the industry. The major problem of this process involves surface melting which results in higher surface roughness after the laser surface treatment. This paper will report the results achieved by a 100 W continuous wave (CW) fiber laser for laser surface treatment without the surface being melted. Laser processing parameters were carefully selected so that the surface could be treated without surface melting and thus the surface finish of the component could be maintained. The surface and microstructural characteristics of the treated samples were examined using x-ray diffractometry, optical microscopy, three-dimensional surface profile and contact angle measurements, and nanoindentation test.