91 resultados para unity gain buffer


Relevância:

20.00% 20.00%

Publicador:

Resumo:

In this paper, gain-bandwidth (GB) trade-off associated with analog device/circuit design due to conflicting requirements for enhancing gain and cutoff frequency is examined. It is demonstrated that the use of a nonclassical source/drain (S/D) profile (also known as underlap channel) can alleviate the GB trade-off associated with analog design. Operational transconductance amplifier (OTA) with 60 nm underlap S/D MOSFETs achieve 15 dB higher open loop voltage gain along with three times higher cutoff frequency as compared to OTA with classical nonunderlap S/D regions. Underlap design provides a methodology for scaling analog devices into the sub-100 nm regime and is advantageous for high temperature applications with OTA, preserving functionality up to 540 K. Advantages of underlap architecture over graded channel (GC) or laterally asymmetric channel (LAC) design in terms of GB behavior are demonstrated. Impact of transistor structural parameters on the performance of OTA is also analyzed. Results show that underlap OTAs designed with spacer-to-straggle ratio of 3.2 and operated below a bias current of 80 microamps demonstrate optimum performance. The present work provides new opportunities for realizing future ultra wide band OTA design with underlap DG MOSFETs in silicon-on-insulator (SOI) technology. Index Terms—Analog/RF, double gate, gain-bandwidth product, .

Relevância:

20.00% 20.00%

Publicador:

Resumo:

A wide tuning range voltage controlled oscillator (VCO) with novel architecture is proposed in this work. The entire circuit consists of a VCO core, a summing circuit, a single-ended to differential (STD) converter and a buffer amplifier. The VCO core oscillates at half the desired frequency and the second harmonic of the VCO core is extracted by the summing circuit, which is then converted to a differential pair by the STD. The entire VCO circuit operates from 58.85 to 70.85 GHz with 20% frequency tuning range. The measured VCO gain is less than 1.6 GHz/V. The measured phase noise at 3 MHz offset is less than -78 dBc/Hz across the entire tuning range. The differential phase error of the output signals is measured by down converting the VCO output signals to low gigahertz frequency using an on-chip mixer. The measured differential phase error is less than 8°. The VCO circuit, which is constructed using 0.35 µm SiGe technology, occupies 770 × 550 µm2 die area and consumes 62 mA under 3.5 V supply.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The hypoxia-inducible factors (HIFs; isoforms HIF-1 alpha, HIF-2 alpha, HIF-3 alpha) mediate many responses to hypoxia. Their regulation is principally by oxygen-dependent degradation, which is initiated by hydroxylation of specific proline residues followed by binding of von Hippel-Lindau (VHL) protein. Chuvash polycythemia is a disorder with elevated HIF. It arises through germline homozygosity for hypomorphic VHL alleles and has a phenotype of hematological, cardiopulmonary, and metabolic abnormalities. This study explores the phenotype of two other HIF pathway diseases: classic VHL disease and HIF-2 alpha gain-of-function mutation. No cardiopulmonary abnormalities were detected in classic VHL disease. HIF-2 alpha gain-of-function mutations were associated with pulmonary hypertension, increased cardiac output, increased heart rate, and increased pulmonary ventilation relative to metabolism. Comparison of the HIF-2 alpha gain-of-function responses with data from studies of Chuvash polycythemia suggested that other aspects of the Chuvash phenotype were diminished or absent. In classic VHL disease, patients are germline heterozygous for mutations in VHL, and the present results suggest that a single wild-type allele for VHL is sufficient to maintain normal cardiopulmonary function. The HIF-2 alpha gain-of-function phenotype may be more limited than the Chuvash phenotype either because HIF-1 alpha is not elevated in the former condition, or because other HIF-independent functions of VHL are perturbed in Chuvash polycythemia.-Formenti, F., Beer, P. A., Croft, Q. P. P., Dorrington, K. L., Gale, D. P., Lappin, T. R. J., Lucas, G. S., Maher, E. R., Maxwell, P. H., McMullin, M. F., O'Connor, D. F., Percy, M. J., Pugh, C. W., Ratcliffe, P. J., Smith, T. G., Talbot, N. P., Robbins, P. A. Cardiopulmonary function in two human disorders of the hypoxia-inducible factor (HIF) pathway: von Hippel-Lindau disease and HIF-2 alpha gain-of-function mutation. FASEB J. 25, 2001-2011 (2011). www.fasebj.org

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Driven by a double 75 ps pulse with 2.2 ns separation, saturated operation of nickel-like Ag, In, Sn, and Sm X-ray lasers have been demonstrated with only 75 J drive energy on target. The variation of X-ray laser output with target length is found to fit well to a simple model for an amplified spontaneous emission (ASE) laser including saturation. Small signal gains of similar to 10 cm(-1), effective gain length products of similar to 18, and saturation irradiance of (1-5)x 10(10) W/cm(2) are measured for these lasers using a fitting procedure. (C) 1998 Elsevier Science B.V. All rights reserved.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The transient-excitation pumping scheme, in which a picosecond duration pulse rapidly heats the plasma preformed by a low-intensity nanosecond pulse, was used to pump the Ne-like germanium, J = 0-1 transition at 19.6 nm. A small-signal gain coefficient of 30 cm(-1) was measured for targets less than or equal to 5 mm long. (C) 1998 Optical Society of America.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Evidence of high gain pumped by recombination has been observed in the 5g-4f transition at 11.1 nn in sodiumlike copper ions with use of a 20-J 2-ps Nd:glass laser system. The time- and space-integrated gain coefficient was 8.8 +/- 1.4 cm(-1), indicating a single-transit amplification of similar to 60 times. This experiment has shown that 2 ps is the optimum pulse duration to drive the sodiumlike copper recombination x-ray lasing at 11.1 nm. (C) 1996 Optical Society of America

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Recombining plasmas produced by picosecond laser pulses are characterized by measuring ratio of intensities of resonance lines of H- and He-like ions in the plasmas. It is found that the rapidly recombining plasmas produced by picosecond laser pulses are suitable for high-gain operation.