36 resultados para systems management


Relevância:

40.00% 40.00%

Publicador:

Resumo:

Purpose
This article aims to analyze the role of performance management systems (PMS) in supporting public value strategies.

Design/methodology/approach
This article draws on the public value dynamic model by Horner and Hutton (2010). It presents the results of a case study of implementation of a PMS model, the ‘Value Pyramid’ (VP).

Findings
The results stress the need for an improved conceptualization of PMS within public value strategy. Through experimentation using the VP, the case site was able to measure and visualize what it considered public value and reflect on the internal/external causes of both creation and destruction of public value.

Research limitations/implication
This article is limited to just one case study, although in-depth and longitudinal.

Originality/value
This article is one of the first attempting to understand the role of PMS within the public value strategy framework, answering the call of Benington and Moore (2010) to consider public value from an accounting perspective.

Relevância:

40.00% 40.00%

Publicador:

Resumo:

The reverse engineering of a skeleton based programming environment and redesign to distribute management activities of the system and thereby remove a potential single point of failure is considered. The Ore notation is used to facilitate abstraction of the design and analysis of its properties. It is argued that Ore is particularly suited to this role as this type of management is essentially an orchestration activity. The Ore specification of the original version of the system is modified via a series of semi-formally justified derivation steps to obtain a specification of the decentralized management version which is then used as a basis for its implementation. Analysis of the two specifications allows qualitative prediction of the expected performance of the derived version with respect to the original, and this prediction is borne out in practice.

Relevância:

40.00% 40.00%

Publicador:

Resumo:

Objective:

The aim of this study was to identify sources of anatomical misrepresentation due to the location of camera mounting, tumour motion velocity and image processing artefacts in order to optimise the 4DCT scan protocol and improve geometrical-temporal accuracy.

Methods:

A phantom with an imaging insert was driven with a sinusoidal superior-inferior motion of varying amplitude and period for 4DCT scanning. The length of a high density cube within the insert was measured using treatment planning software to determine the accuracy of its spatial representation. Scan parameters were varied including the tube rotation period and the cine time between reconstructed images. A CT image quality phantom was used to measure various image quality signatures under the scan parameters tested.

Results:

No significant difference in spatial accuracy was found for 4DCT scans carried out using the wall mounted or couch mounted camera for sinusoidal target motion. Greater spatial accuracy was found for 4DCT scans carried out using a tube rotation speed of 0.5s rather than 1.0s. The reduction in image quality when using a faster rotation speed was not enough to require an increase in patient dose.

Conclusions:

4DCT accuracy may be increased by optimising scan parameters, including choosing faster tube rotation speeds. Peak misidentification in the recorded breathing trace leads to spatial artefacts and this risk can be reduced by using a couch mounted infrared camera.

Advances in knowledge:

This study explicitly shows that 4DCT scan accuracy is improved by scanning with a faster CT tube rotation speed.