103 resultados para strip detectors


Relevância:

10.00% 10.00%

Publicador:

Resumo:

When viewing two superimposed, translating sets of dots moving in different directions, one overestimates the direction difference. This phenomenon of direction repulsion is thought to be driven by inhibitory interactions between directionally tuned motion detectors [1, 2]. However, there is disagreement on where this occurs — at early stages of motion processing [1, 3], or at the later, global motion-processing stage following “pooling” of these measures [4–6]. These two stages of motion pro - cessing have been identified as occurring in area V1 and the human homolog of macaque MT/V5, respectively[7, 8]. We designed experiments in which local and global predictions of repulsion are pitted against one another. Our stimuli contained a target set of dots, moving at a uniform speed, superimposed on a “mixed-speed” distractor set. Because the perceived speed of a mixed-speed stimulus is equal to the dots’ average speed [9], a global-processing account of direction repulsion predicts that repulsion magnitude induced by a mixed-speed distractor will be indistinguishable from that induced by a single-speed distractor moving at the same mean speed. This is exactly what we found. These results provide compelling evidence that global-motion interactions play a major role in driving direction repulsion.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Background & Aims: Wide between-center variation in adenoma detection rates (ADRs) was observed in the U.K. Flexible Sigmoidoscopy Screening Trial (overall, 12.1%; range, 8.6%-15.9%; P <0.0001). The aim of this study was to determine whether the observed differences could be attributed to varying performance by endoscopists, to examine the effect of experience on performance, and to identify an attainable, standard ADR to which endoscopists could aspire. 

Methods: Thirteen medical endoscopists, one per trial center, each performed about 3000 examinations (200 per month) using the same equipment and protocol. Overall and monthly ADRs were compared using multivariable logistic regression. 

Results: Differences in ADRs were not explained by patient characteristics, incidence of colorectal cancer in the local population, or the endoscopists' medical specialty or previous experience. Average ADRs increased significantly with screening experience (up to 400 examinations). Endoscopists were classified as higher, intermediate, or lower adenoma detectors, and performance levels were maintained over time. Higher detectors had ADRs of 15% overall (men, 20%; women, 10%) and also detected more adenomas per case (higher/lower detectors, 21.7/10.4 adenomas per :100 examinations). 

Conclusions: The differences in ADRs were due to variation in performance of the endoscopists. Long-term follow-up will determine whether this variation is clinically important. We suggest that the standards in higher detecting centers should be achievable by all endoscopists screening unscreened populations aged older than 55 years. Endoscopists should aim to stay above the lower 95% confidence interval band for 200 examinations (10% overall; 5% in women, 15% in men).

Relevância:

10.00% 10.00%

Publicador:

Resumo:

This paper proposes a modification to the ACI 318-02 equivalent frame method of analysis of reinforced concrete flat plate exterior panels. Two existing code methods were examined: ACI 318 and BS 8110. The derivation of the torsional stiffness of the edge strip as proposed by ACI 318 is examined and a more accurate estimate of this value is proposed, based on both theoretical analysis and experimental results. A series of 1/3-scale models of flat plate exterior panels have been tested. Unique experimental results were obtained by measuring strains in reinforcing bars at approximately 200 selected locations in the plate panel throughout the entire loading history. The measured strains were used to calculate curvature and, hence, bending moments; these were used along with moments in the columns to assess the accuracy of the equivalent frame methods. The proposed method leads to a more accurate prediction of the moments in the plate at the column front face, at the panel midspan, and in the edge column. Registered Subscribers: View the full article. This document is available as a free download to qualified members. An electronic (PDF) version is available for purchase and download. Click on the Order Now button to continue with the download.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Measures of entanglement, fidelity, and purity are basic yardsticks in quantum-information processing. We propose how to implement these measures using linear devices and homodyne detectors for continuous-variable Gaussian states. In particular, the test of entanglement becomes simple with some prior knowledge that is relevant to current experiments.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

It is shown that a linear superposition of two macroscopically distinguishable optical coherent states can be generated using a single photon source and simple all-optical operations. Weak squeezing on a single photon, beam mixing with an auxiliary coherent state, and photon detecting with imperfect threshold detectors are enough to generate a coherent state superposition in a free propagating optical field with a large coherent amplitude (alpha>2) and high fidelity (F>0.99). In contrast to all previous schemes to generate such a state, our scheme does not need photon number resolving measurements nor Kerr-type nonlinear interactions. Furthermore, it is robust to detection inefficiency and exhibits some resilience to photon production inefficiency.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

An electron beam ion trap ( EBIT) has been designed and is currently under construction for use in atomic physics experiments at the Queen's University, Belfast. In contrast to traditional EBITs where pairs of superconducting magnets are used, a pair of permanent magnets will be used to compress the electron beam. The permanent magnets have been designed in conjunction with bespoke vacuum ports to give unprecedented access for photon detection. Furthermore, the bespoke vacuum ports facillitate a versatile, reconfigurable trap structure able to accommodate various in-situ detectors and in-line charged particle analysers. Although the machine will have somewhat lower specifications than many existing EBITs in terms of beam current density, it is hoped that the unique features will facilitate a number of hitherto impossible studies involving interactions between electrons and highly charged ions. In this article the new machine's design is outlined along with some suggestions of the type of process to be studied once the construction is completed.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

The photometric and spectroscopic properties of 26 well-observed Type Ia Supernovae (SNe Ia) were analyzed with the aim of exploring SN Ia diversity. The sample includes (Branch) normal SNe, as well as extreme events such as SN 1991T and SN 1991bg, while the truly peculiar SNe Ia, SN 2000cx and SN 2002cx, are not included in our sample. A statistical treatment reveals the existence of three different groups. The first group (FAINT) consists of faint SNe Ia similar to SN 1991bg, with low expansion velocities and rapid evolution of Si II velocity. A second group consists of normal SNe Ia, also with high temporal velocity gradient (HVG), but with brighter mean absolute magnitude =-19.3 and higher expansion velocities than the FAINT SNe. The third group includes both normal and SN 1991T-like SNe Ia: these SNe populate a narrow strip in the Si II velocity evolution plot, with a low-velocity gradient (LVG), but have absolute magnitudes similar to HVGs. While the FAINT and HVG SNe Ia together seem to define a relation between R(Si II) and ���m15(B), the LVG SNe either do not conform to that relation or define a new, looser one. The R(Si II) premaximum evolution of HVGs is strikingly different from that of LVGs. We discuss the impact of this evidence on the understanding of SN Ia diversity, in terms of explosion mechanisms, degree of ejecta mixing, and ejecta-circumstellar material interaction.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Germanium (Ge) does not grow a suitable oxide for MOS devices. The Ge/dielectric interface is of prime importance to the operation of photo-detectors and scaled MOSTs. Therefore there is a requirement for deposited or bonded dielectric materials. MOS capacitors have been formed on germanium substrates with three different dielectric materials. Firstly, a thermally grown and bonded silicon dioxide (SiO2) layer, secondly, SiO2 deposited by atmospheric pressure CVD ‘silox’, and thirdly a hafnium oxide (HfO2) high-k dielectric deposited by atomic layer deposition (ALD). Ge wafers used were p-type 1 0 0 2 O cm. C–V measurements have been made on all three types of capacitors to assess the interface quality. ALD HfO2 and silox both display acceptable C–V characteristics. Threshold voltage and maximum and minimum capacitance values closely match expected values found through calculation. However, the bonded SiO2 has non-ideal C–V characteristics, revealing the presence of a high density of interface states. A H2/N2 post metal anneal has a detrimental effect on C–V characteristics of HfO2 and silox dielectrics, causing a shift in the threshold voltage and rise in the minimum capacitance value. In the case of hafnium dioxide, capacitor properties can be improved by performing a plasma nitridation of the Ge surface prior to dielectric deposition.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

The seasonal activity of Leisler's bat Nyctalus leisleri and pipistrelle bats Pipistrellus spp. with respect to minimum bat numbers and habitat use were investigated in County Down, Northern Ireland using a driven transect from April 1998 to October 1998. Data were collected in lowland farmland near Belfast, Northern Ireland using two BatBox III bat detectors tuned to detect both species and species groups simultaneously. The number of bats/km increased during April, May and June, peaking in July and tailed off after this period. The main peak in July is assumed to reflect the occurrence of newly volant young. An increase in the number of pipistrelle social calls during August and September probably represented mating activity. Bat activity correlated with temperature in both N. leisleri and Pipistrellus spp., although bat numbers were independent of temperature after the middle of June. There was significant variation in habitat use by pipistrelle bats along roads over the study period. Pipistrelle bats were observed in greater numbers in areas of tree-line, cut hedge (

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Livestock face complex foraging options associated with optimizing nutrient intake while being able to avoid areas posing risk of parasites or disease. Areas of tall nutrient-rich swards around fecal deposits may be attractive for grazing, but might incur fitness costs from parasites. We use the example of dairy cattle and the risks of tuberculosis transmission posed to them by pastures contaminated with badger excreta to examine this trade-off. A risk may be posed either by aerosolized inhalation through investigation or by ingestion via grazing contaminated swards. We quantified the levels of investigation and grazing of 150 dairy cows at badger latrines (accumulations of feces and urine) and crossing points (urination-only sites). Grazing behavior was compared between strip-grazed and rotation-grazed fields. Strip grazing had fields subdivided for grazing periods of

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Recent advances in the development of 2D microstrip detectors open up new possibilities for hard x-ray spectroscopy, in particular for polarization studies. These detectors make ideal Compton polarimeters, which enable us to study precisely the polarization of hard x-rays. Here, we present recent results from measurements of Radiative Electron Capture into the K-shell of highly-charged uranium ions. The experiments were performed with a novel 2D Si(Li) Compton polarimeter at the Experimental Storage Ring at GSI. Stored and cooled beams of U91+ and U92+ ions, with kinetic energies of 43 MeV/u and 96 MeV/u respectively, were crossed with a hydrogen gasjet. The preliminary data analysis shows x-rays from the K-REC process, emitted perpendicularly to the ion beam, to be strongly linearly polarized.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Simple analytical formulas are introduced for the grid impedance of electrically dense arrays of square patches and for the surface impedance of high-impedance surfaces based on the dense arrays of metal strips or square patches over ground planes. Emphasis is on the oblique-incidence excitation. The approach is based on the known analytical models for strip grids combined with the approximate Babinet principle for planar grids located at a dielectric interface. Analytical expressions for the surface impedance and reflection coefficient resulting from our analysis are thoroughly verified by full-wave simulations and compared with available data in open literature for particular cases. The results can be used in the design of various antennas and microwave or millimeter wave devices which use artificial impedance surfaces and artificial magnetic conductors (reflect-array antennas, tunable phase shifters, etc.), as well as for the derivation of accurate higher-order impedance boundary conditions for artificial (high-) impedance surfaces. As an example, the propagation properties of surface waves along the high-impedance surfaces are studied.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

The coordination of olefins to square-planar Pd(II) and Pt(II) complexes containing 2,9-dimethylphenanthroline (L1) often involves a change of color associated with a change of geometry at the metal center. In order to obtain suitable colorimetric detectors for ethylene gas, a series of new Pd(II) and Pt(II) compounds with a range of 2,9-disubstituted phenanthroline ligands [2,9-di-n-butyl-1,10-phenanthroline (L-2), 2,9-di-s-butyl-1,10-phenanthroline (L3), 2,9-diphenyl-1,10-phenanthroline (L4), and 2,9-dimethyl-4,7-diphenyl-1,10-phenanthroline (bathocuproine, L5)] have been prepared and their reactivity toward ethylene investigated both in solution and after depositing the detector compounds on a variety of solid supports. The Pd(II) complex [PdCl2(L2)] supported on silica undergoes a clear color change upon exposure to ethylene, while remaining stable toward air and water, and forms the basis for new simple colorimetric detectors with potential applications in ethylene pipe-leak detection and the monitoring of fruit ripening. Encouragingly, the detector is able to discriminate between fruit at different stages of ripening. The response of the detector to other volatiles was also examined, and specific color changes were also observed upon exposure to aromatic acetylenes. The crystal structures of four new derivatives, including the ethylene-Pt(II) complex [PtCl2(C2H4)(L2)], are also described.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

We describe an experimental system designed for single-shot photoelectron spectroscopy on free atoms and molecules at the Free Electron Laser in Hamburg (FLASH at DESY). The combination of the extreme ultra-violet (EUV) Free Electron Laser and a temporally synchronized optical fs laser (Ti:Sapphire) enables a variety of two-color pump-probe experiments. The spectral, temporal and spatial characteristics of both the EUV FEL and the optical laser pulses, the experimental procedure to control their overlap as well as the performance of an electron spectrometer used to obtain single-shot photoelectron spectra are discussed. As an illustration of the capabilities of this set-up, some results on two-photon two-color ionization of rare gases are presented. (c) 2007 Elsevier B.V. All rights reserved.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

A pin diode-loaded active doubly periodic flat strip FSS is shown to act as a dynamic screen. It is shown that by means of d.c. bias control, we can utilize the screen in, (1) transmission mode as a dual band electromagnetic shutter, or with the inclusion of a ground plane in reflection mode, (is (2) it dual band refection canceller. (3) an amplitude shift keying (ASK) spatial modulator. The properties of the FSS are characterized using a specially designed parallel plate waveguide simulator that permits normal incidence excitation of the FSS under test. (C) 2009 Wiley Periodicals. Inc. Microwave Opt Technol Lett 51: 2059-2061, 2009; Published online in Wiley Inter-Science (www. interscience.wiley.com). DOI 10.1002/mop.24547