64 resultados para room set up


Relevância:

80.00% 80.00%

Publicador:

Resumo:

Capillary-based systems for measuring the input impedance of musical wind instruments were first developed in the mid-20th century and remain in widespread use today. In this paper, the basic principles and assumptions underpinning the design of such systems are examined. Inexpensive modifications to a capillary-based impedance measurement set-up made possible due to advances in computing and data acquisition technology are discussed. The modified set-up is able to measure both impedance magnitude and impedance phase even though it only contains one microphone. In addition, a method of calibration is described that results in a significant improvement in accuracy when measuring high impedance objects on the modified capillary-based system. The method involves carrying out calibration measurements on two different objects whose impedances are well-known theoretically. The benefits of performing two calibration measurements (as opposed to the one calibration measurement that has been traditionally used) are demonstrated experimentally through input impedance measurements on two test objects and a Boosey and Hawkes oboe. © S. Hirzel Verlag · EAA.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

Objective: to identify non-invasive interventions in the perinatal period that could enable midwives to offer effective support to women within the area of maternal mental health and well-being.

Methods: a total of 9 databases were searched: MEDLINE, PubMed, EBSCO (CINAHL/British Nursing Index), MIDIRS Online Database, Web of Science, The Cochrane library, CRD (NHS EED/DARE/HTA), Joanne Briggs Institute and EconLit. A systematic search strategy was formulated using key MeSH terms and related text words for midwifery, study aim, study design and mental health. Inclusion criteria were articles published from 1999 onwards, English language publications and articles originating from economically developed countries, indicated by membership of the Organisation for Economic Co-operation and Development (OECD). Data were independently extracted using a data collection form, which recorded data on the number of papers reviewed, time frame of the review, objectives, key findings and recommendations. Summary data tables were set up outlining key data for each study and findings were organised into related groups. The methodological quality of the reviews was assessed based on predefined quality assessment criteria for reviews.

Findings: 32 reviews were identified as examining interventions that could be used or co-ordinated by midwives in relation to some aspect of maternal mental health and well-being from the antenatal to the postnatal period and met the inclusion criteria. The review highlighted that based on current systematic review evidence it would be premature to consider introducing any of the identified interventions into midwifery training or practice. However there were a number of examples of possible interventions worthy of further research including midwifery led models of care in the prevention of postpartum depression, psychological and psychosocial interventions for treating postpartum depression and facilitation/co-ordination of parent-training programmes. No reviews were identified that supported a specific midwifery role in maternal mental health and well-being in pregnancy, and yet, this is the point of most intensive contact.

Key conclusions and implications for practice: This systematic review of systematic reviews provides a valuable overview of the current strengths and gaps in relation to maternal mental health interventions in the perinatal period. While there was little evidence identified to inform the current role of midwives in maternal mental health, the review provides the opportunity to reflect on what is achievable by midwives now and in the future and the need for high quality randomised controlled trials to inform a strategic approach to promoting maternal mental health in midwifery.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

The purpose of this study was to investigate the occupational hazards within the tanning industry caused by contaminated dust. A qualitative assessment of the risk of human exposure to dust was made throughout a commercial Kenyan tannery. Using this information, high-risk points in the processing line were identified and dust sampling regimes developed. An optical set-up using microscopy and digital imaging techniques was used to determine dust particle numbers and size distributions. The results showed that chemical handling was the most hazardous (12 mg m(-3)). A Monte Carlo method was used to estimate the concentration of the dust in the air throughout the tannery during an 8 h working day. This showed that the high-risk area of the tannery was associated with mean concentrations of dust greater than the UK Statutory Instrument 2002 No. 2677. stipulated limits (exceeding 10 mg m(-3) (Inhalable dust limits) and 4 mg m(-3) (Respirable dust limits). This therefore has implications in terms of provision of personal protective equipment (PPE) to the tannery workers for the mitigation of occupational risk.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

Framings provide a way to construct Quillen functors from simplicial sets to any given model category. A more structured set- up studies stable frames giving Quillen functors from spectra to stable model categories. We will investigate how this is compatible with Bousfield localisation to gain insight into the deeper structure of the stable homotopy category. We further show how these techniques relate to rigidity questions and how they can be used to study algebraic model categories.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

The answer to the question of what it means to say that a right is absolute is often taken for granted, yet still sparks doubt and scepticism. This article investigates absoluteness further, bringing rights theory and the judicial approach on an absolute right together. A theoretical framework is set up that addresses two distinct but potentially related parameters of investigation: the first is what I have labelled the ‘applicability’ criterion, which looks at whether and when the applicability of the standard referred to as absolute can be displaced, in other words whether other considerations can justify its infringement; the second parameter, which I have labelled the ‘specification’ criterion, explores the degree to which and bases on which the content of the standard characterised as absolute is specified. This theoretical framework is then used to assess key principles and issues that arise in the Strasbourg Court’s approach to Article 3. It is suggested that this analysis allows us to explore both the distinction and the interplay between the two parameters in the judicial interpretation of the right and that appreciating the significance of this is fundamental to the understanding of and discourse on the concept of an absolute right.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

In this work, we demonstrate a very high-energy density and high-temperature stability capacitor based on SrTiO3-substituted BiFeO3 thin films. An energy density of 18.6 J/cm3 at 972 kV/cm is reported. The temperature coefficient of capacitance (TCC) was below 11% from room temperature up to 200°C. These results are of practical importance, because it puts forward a promising novel and environmentally friendly, lead-free material, for high-temperature applications in power electronics up to 200°C. Applications include capacitors for low carbon vehicles, renewable energy technologies, integrated circuits, and for the high-temperature aerospace sector. © 2013 Crown copyright

Relevância:

80.00% 80.00%

Publicador:

Resumo:

Respiratory motion introduces complex spatio-temporal variations in the dosimetry of radiotherapy and may contribute towards uncertainties in radiotherapy planning. This study investigates the potential radiobiological implications occurring due to tumour motion in areas of geometric miss in lung cancer radiotherapy. A bespoke phantom and motor-driven platform to replicate respiratory motion and study the consequences on tumour cell survival in vitro was constructed. Human non-small-cell lung cancer cell lines H460 and H1299 were irradiated in modulated radiotherapy configurations in the presence and absence of respiratory motion. Clonogenic survival was calculated for irradiated and shielded regions. Direction of motion, replication of dosimetry by multi-leaf collimator (MLC) manipulation and oscillating lead shielding were investigated to confirm differences in cell survival. Respiratory motion was shown to significantly increase survival for out-of-field regions for H460/H1299 cell lines when compared with static irradiation (p <0.001). Significantly higher survival was found in the in-field region for the H460 cell line (p <0.030). Oscillating lead shielding also produced these significant differences. Respiratory motion and oscillatory delivery of radiation dose to human tumour cells has a significant impact on in- and out-of-field survival in the presence of non-uniform irradiation in this in vitro set-up. This may have important radiobiological consequences for modulated radiotherapy in lung cancer. 

Relevância:

80.00% 80.00%

Publicador:

Resumo:

Despite the growing use of apologies in post-conflict settings, cases of non-apology remain unaddressed and continue to puzzle scholars. This article focuses on the absence of apology by non-state and anti-state actors by examining the case of the Cypriot armed group EOKA, which has refused to offer an apology to the civilian victims of its ‘anti-colonial’ struggle (1955–1959). Using field data and parliamentary debates, and drawing on comparisons, this article analyses the factors that contributed to a lack of apology. It is argued that the inherited timelessness of Greek nationalism, and the impression of a perpetual need for defence, set up textbook conditions for the development of a hegemonic discourse and prevented an apology for human rights violations.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

In recent years distillers dried grains and solubles (DDGS), co-products of the bio-ethanol and beverages industries, have become globally traded commodity for the animal feed sector. As such it is becoming increasingly important to be able to trace the geographical origin of commodities in case of a contamination incident or authenticity issue arise. In this study, 137 DDGS samples from a range of different geographical origins (China, USA, Canada and European Union) were collected and analyzed. Isotope ratio mass spectrometry (IRMS) was used to analyze the DDGS for up>2up>H/up>1up>H, up>13up>C/up>12up>C, up>15up>N/up>14up>N, up>18up>O/up>16up>O and up>34up>S/up>32up>S isotope ratios which can vary depending on geographical origin and processing. Univariate and multivariate statistical techniques were employed to investigate the feasibility of using the IRMS data to determine botanical and geographical origin of the DDGS. The results indicated that this commodity could be differentiated according to their place of origin by the analysis of stable isotopes of hydrogen, carbon, nitrogen and oxygen but not with sulfur. By adding data to the models produced in this study, potentially an isotope databank could be set up for traceability procedures for DDGS, similar to the one established already for wine which will help in feed and food security issues arising worldwide.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

An electronically tunable reflection polarizer which exploits the dielectric anisotropy of nematic liquid crystals (LC) has been designed, fabricated and measured in a frequency band centered at 130 GHz. The phase agile polarizing mirror converts an incident slant 45° signal upon reflection to right hand circular (RHCP), orthogonal linear (-45 °) or left hand circular (LHCP) polarization depending on the value of the voltage biasing the LC mixture. In the experimental set-up this is achieved by applying a low frequency bias voltage of 0 V, 40 V and 89 V respectively, across the cavity containing the LC material.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

Abstract Image

An asymmetric total synthesis of the mast cell inhibitor (+)-monanchorin is reported in which a Sharpless AD on 11 and a cyclic sulfate ring opening with an azide feature as key steps. After further manipulation, a novel guanidine-controlled ester reduction provided the guanidine-hemiaminal 25 which underwent Wittig olefination to give 27. Hydrogenation and a second guanidine-controlled reduction of the ester in 28, to obtain aldehyde 29, then set up a trifluoroacetic acid mediated cyclization to give (+)-monanchorin TFA salt.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

Light of wavelength 632.8 nm and p-polarization is incident on a prism-air gap (varied from 0.7 to 7 mum)-Al-GaAs arrangement. Both the photosignal generated by the Schottky diode and the reflectance are measured as a function of the internal angle of incidence in the prism. There is significant, well-defined enhancement of the photosignal, up to a factor of approximately 7.5, associated with two different types of enhanced absorption modes. For air gaps <1.5 mum there is photosignal enhancement due to an enhanced absorption feature (reflectance dip) that occurs at an angle of incidence just above critical angle in the prism; this feature corresponds to the excitation of a surface plasmon polariton at the Al-air interface. For air gaps > 1 mum there are between one and ten photoresponse peaks at input angles less than the critical angle. The corresponding enhanced absorption features are due to leaky guided wave modes set up in the air gap.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

The measurement and representation of the electrical activity of muscles [electromyography (EMG)] have a long history from the Victorian Era until today. Currently, EMG has uses both as a research tool, in noninvasively recording muscle activation, and clinically in the diagnosis and assessment of nerve and muscle disease and injury as well as in assessing the recovery of neuromuscular function after nerve damage. In the present report, we describe the use of a basic EMG setup in our teaching laboratories to demonstrate some of these current applications. Our practical also illustrates some fundamental physiological and structural properties of nerves and muscles. Learning activities include 1) displaying the recruitment of muscle fibers with increasing force development; 2) the measurement of conduction velocity of motor nerves; 3) the assessment of reflex delay and demonstration of Jendrassik's maneuver; and 4) a Hoffman reflex experiment that illustrates the composition of mixed nerves and the differential excitability thresholds of fibers within the same nerve, thus aiding an understanding of the reflex nature of muscle control. We can set up the classes at various levels of inquiry depending on the needs/professional requirements of the class. The results can then provide an ideal platform for a discovery learning session/tutorial on how the central nervous system controls muscles, giving insights on how supraspinal control interacts with reflexes to give smooth, precise muscular activation.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

Purpose. To investigate the robustness of single vocal cord intensity modulated radiation therapy (IMRT) treatment plans for set-up errors, respiration, and deformation. Material and methods. Four-dimensional computed tomography (4D-CT) scans of 10 early glottic carcinoma patients, previously treated with conventional techniques, were used in this simulation study. For each patient a pre-treatment 4D-CT was used for IMRT planning, generating a reference dose distribution. Prescribed PTV dose was 66 Gy. The impact of systematic set-up errors was simulated by applying shifts of ± 2 mm to the planning CT scans, followed by dose re-calculation with original beam segments, MUs, etc. Effects of respiration and deformation were determined utilizing extreme inhale and exhale CT scans, and repeat scans acquired after 22 Gy, 44 Gy, and 66 Gy, respectively. All doses were calculated using Monte Carlo dose simulations. Results. Considering all investigated geometrical perturbations, reductions in the clinical target volume (CTV) V95%, D98%, D2%, and generalized equivalent uniform dose (gEUD) were limited to 1.2 ± 2.2%, 2.4 ± 2.9%, 0.2 ± 1.8%, and 0.6 ± 1.1 Gy, respectively. The near minimum dose, D98%, was always higher than 89%, and gEUD always remained higher than 66 Gy. Planned contra-lateral (CL) vocal cord DMean, gEUD, and V40 Gy were 38.2 ± 6.0 Gy, 43.4 ± 5.6 Gy, and 42.7 ± 14.9%. With perturbations these values changed by -0.1 ± 4.3 Gy, 0.1 ± 4.0 Gy, and -1.0 ± 9.6%, respectively. Conclusions. On average, CTV dose reductions due to geometrical perturbations were very low, and sparing of the CL vocal cord was maintained. In a few observations (6 of 103 simulated situations), the near-minimum CTV-dose was around 90%, requiring attention in deciding on a future clinical protocol. 

Relevância:

80.00% 80.00%

Publicador:

Resumo:

Background and purpose: We are developing a technique for highly focused vocal cord irradiation in early glottic carcinoma to optimally treat a target volume confined to a single cord. This technique, in contrast with the conventional methods, aims at sparing the healthy vocal cord. As such a technique requires sub-mm daily targeting accuracy to be effective, we investigate the accuracy achievable with on-line kV-cone beam CT (CBCT) corrections. Materials and methods: CBCT scans were obtained in 10 early glottic cancer patients in each treatment fraction. The grey value registration available in X-ray volume imaging (XVI) software (Elekta, Synergy) was applied to a volume of interest encompassing the thyroid cartilage. After application of the thus derived corrections, residue displacements with respect to the planning CT scan were measured at clearly identifiable relevant landmarks. The intra- and inter-observer variations were also measured. Results: While before correction the systematic displacements of the vocal cords were as large as 2.4 ± 3.3 mm (cranial-caudal population mean ± SD Σ), daily CBCT registration and correction reduced these values to less than 0.2 ± 0.5 mm in all directions. Random positioning errors (SD σ) were reduced to less than 1 mm. Correcting only for translations and not for rotations did not appreciably affect this accuracy. The residue random displacements partly stem from intra-observer variations (SD = 0.2-0.6 mm). Conclusion: The use of CBCT for daily image guidance in combination with standard mask fixation reduced systematic and random set-up errors of the vocal cords to <1 mm prior to the delivery of each fraction dose. Thus, this facilitates the high targeting precision required for a single vocal cord irradiation. © 2009 Elsevier Ireland Ltd. All rights reserved.