117 resultados para reactor safety


Relevância:

20.00% 20.00%

Publicador:

Resumo:

This paper serves as a reminder to those working clinically in the field of trauma of the necessity for therapists to adequately include issues of safety within the therapeutic process. Addressing these issues is an integral part of the therapy and not simply a practical prerequisite or a parallel process. Validation of this thesis is drawn from trauma literature and an account of safety issues relating to the therapeutic setting and processes is given. Case examples illustrate the type of issues that might usefully be addressed within the therapeutic context to increase individual and family safety for clients as they continue to live within their local communities. This paper draws on recent work undertaken at the Family Trauma Centre. This Centre, based in South Belfast, is in its second year of operation. The Family Trauma Centre has a primary remit to provide clinical treatment for children and their families suffering from the traumatic effects of the ‘Troubles’ in Northern Ireland. The community context for this work has been one of continuous low-grade conflict in the midst of a ‘Peace’ process.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

BACKGROUND: HIV microbicide trials have emphasized the need to evaluate the safety of topical microbicides and delivery platforms in an animal model prior to conducting clinical efficacy trials. An ideal delivery device should provide sustainable and sufficient concentrations of effective products to prevent HIV transmission while not increasing transmission risk by either local mucosal inflammation and/or disruption of the normal vaginal microflora.

METHODS: Safety analyses of macaque-sized elastomeric silicone and polyurethane intravaginal rings (IVRs) loaded with candidate antiretroviral (ARV) drugs were tested in four studies ranging in duration from 49 to 73 days with retention of the IVR being 28 days in each study. Macaques were assigned to 3 groups; blank IVR, ARV-loaded IVR, and naïve. In sequential studies, the same macaques were used but rotated into different groups. Mucosal and systemic levels of cytokines were measured from vaginal fluids and plasma, respectively, using multiplex technology. Changes in vaginal microflora were also monitored. Statistical analysis (Mann-Whitney test) was used to compare data between two groups of unpaired samples (with and without IVR, and IVR with and without ARV) for the groups collectively, and also for individual macaques.

RESULTS: There were few statistically significant differences in mucosal and systemic cytokine levels measured longitudinally when the ring was present or absent, with or without ARVs. Of the 8 proinflammatory cytokines assayed a significant increase (p = 0.015) was only observed for IL8 in plasma with the blank and ARV loaded IVR (median of 9.2 vs. 5.7 pg/ml in the absence of IVR). There were no significant differences in the prevalence of H2O2-producing lactobacilli or viridans streptococci, or other microorganisms indicative of healthy vaginal microflora. However, there was an increase in the number of anaerobic gram negative rods in the presence of the IVR (p= < 0.0001).

CONCLUSIONS: IVRs with or without ARVs neither significantly induce the majority of potentially harmful proinflammatory cytokines locally or systemically, nor alter the lactobacillus or G. vaginalis levels. The increase in anaerobic gram negative rods alone suggests minimal disruption of normal vaginal microflora. The use of IVRs as a long-term sustained delivery device for ARVs is promising and preclinical studies to demonstrate the prevention of transmission in the HIV/SHIV nonhuman primate model should continue.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Many promising therapeutic agents are limited by their inability to reach the systemic circulation, due to the excellent barrier properties of biological membranes, such as the stratum corneum (SC) of the skin or the sclera/cornea of the eye and others. The outermost layer of the skin, the SC, is the principal barrier to topically-applied medications. The intact SC thus provides the main barrier to exogenous substances, including drugs. Only drugs with very specific physicochemical properties (molecular weight <500 Da, adequate lipophilicity, and low melting point) can be successfully administered transdermally. Transdermal delivery of hydrophilic drugs and macromolecular agents of interest, including peptides, DNA, and small interfering RNA is problematic. Therefore, facilitation of drug penetration through the SC may involve by-pass or reversible disruption of SC molecular architecture. Microneedles (MNs), when used to puncture skin, will by-pass the SC and create transient aqueous transport pathways of micron dimensions and enhance the transdermal permeability. These micropores are orders of magnitude larger than molecular dimensions, and, therefore, should readily permit the transport of hydrophilic macromolecules. Various strategies have been employed by many research groups and pharmaceutical companies worldwide, for the fabrication of MNs. This review details various types of MNs, fabrication methods and, importantly, investigations of clinical safety of MN.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Background: Drug scenes within several countries have changed in recent years to incorporate a range of licit psychoactive products, collectively known as “legal highs.” Hundreds of different legal high products have been described in the literature. Many of these products contain synthetic stimulants that allegedly
“mirror” the effects of some illicit drugs. In 2009–2010, growing concern by the UK and Irish governments focused on mephedrone, a synthetic stimulant that had become embedded within several drug scenes in Britain and Ireland. In April 2010, mephedrone and related cathinone derivatives were banned under
the UK’s Misuse of Drugs Act 1971. Setting aside “worse case scenarios” that have been portrayed by UK and Irish media, little is known about mephedrone use from the consumer’s perspective. The purpose of this paper was to (1) explore respondents’ experiences with mephedrone, (2) examine users’ perceptions
about the safety of mephedrone, and primarily to (3) examine sources of mephedrone supply during the pre- and post-ban periods.
Methods: Semi-structured interviews were conducted with 23 adults who had used mephedrone during 2009–2010. Data collection occurred in May and June 2010, following the ban on mephedrone. A total of 20/23 respondents had used mephedrone during the post-ban period, and the vast majority had prior
experience with ecstasy or cocaine. Respondents’ ages ranged from 19 to 51, approximately half of the sample were female and the majority (19 of 23) were employed in full- or part-time work.
Results: Most respondents reported positive experiences with mephedrone, and for some, the substance emerged as a drug of choice. None of the respondents reported that the once-legal status of mephedrone implied that it was safe to use. Very few respondents reported purchasing mephedrone from street-based
or on-line headshops during the pre-ban period, and these decisions were guided in part by respondents’ attempts to avoid “drug user” identities. Most respondents purchased or obtained mephedrone from friends or dealers, and mephedrone was widely available during the 10-week period following the ban. Respondents reported a greater reliance on dealers and a change in mephedrone packaging following the criminalisation of mephedrone.
Conclusion: The findings are discussed in the context of what appears to be a rapidly changing mephedrone market. We discuss the possible implications of criminalising mephedrone, including the potential displacement effects and the development of an illicit market.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Contemporary medical science is reliant upon the rational selection and utilization of devices, and therefore, an increasing need has developed for in vitro systems aimed at replicating the conditions to which urological devices will be subjected to during their use in vivo. We report the development and validation of a novel continuous flow encrustation model based on the commercially available CDC biofilm reactor. Proteus mirabilis-induced encrustation formation on test biomaterial sections under varying experimental parameters was analyzed by X-ray diffraction, infrared- and Raman spectroscopy and by scanning electron microscopy. The model system produced encrusted deposits similar to those observed in archived clinical samples. Results obtained for the system are highly reproducible with encrustation being rapidly deposited on test biomaterial sections. This model will have utility in the rapid screening of encrustation behavior of biomaterials for use in urological applications. (C) 2010 Wiley Periodicals. Inc. J Biomed Mater Res Part B: Appl Biomater 93B: 128-140, 2010

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The objective of this paper is to identify the various managerial constraints, difficulties and issues encountered and resulting strategies adopted, to aid in the management of the various and often complex health and safety concerns, which occur within a confined construction site. This is achieved through classifying the various managerial burdens encountered with the numerous strategies adopted, to ensure the successful management of such confined environments within the realm of health and safety. Through an extensive literature review and detailed interviews, a comprehensive insight into the health and safety concerns within a confined construction site environment is portrayed. The leading managerial strategies to the management of health and safety on confined construction sites may be listed as follows; (1) Traffic Management Plan, (2) Effective Resource Management Plan, (3) Temporary Facilities Management Plan, (4) Safe System of Work Plan, (5) Site Safety Plan, (6) Design Site Layout, (7) Space Management Plan, (8) Effective Program Management, and (9) Space Scheduling. Based on the research, it can be concluded, that through effective management of these issues identified coupled with implementing the various strategies highlighted; successful management of health and safety within a confined construction site environment is attainable.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Globalisation has had a major impact on the engineering industry as pacific Rim countries undercut manufacturing costs and provide a more cost-effective location for many businesses. Engineering in Nortehrn Ireland has mostly declined owing to increased competition from these countries. Engineering companies are now forced to streamline their production processes and employ cost-reducing practices in order to meet customer demands at reduced prices. This article aims to analyse the effects of one such streamlining endeavour which was first introduced after World War II in Japan- 'lean manufacturing' . 'Lean manufacturing' aims to reduce all wasteful activities within the production process in order to improve productivity, while reducing manufacturing costs. The work-based project under consideration was concerned with the impact 'lean manufacturing' may have on health and safety performance and education within an engineering company. The focus of the project was to determine through work-based research, and quantitative analysis, the employee perception on health and safety: has it changed (either positively or negatively), as a consequence of implementing 'lean manufacturing'.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Single-phase microreactors and micro-heat-exchangers have been widely used in industrial and scientific applications over the last decade. In several cases, operation of microreactors has shown that their expected efficiency cannot be reached either due to non-uniform distribution of reactants between different channels or due to flow maldistribution between individual microreactors working in parallel. The latter problem can result in substantial temperature deviations between different microreactors resulting in thermal run away which could arise from an exothermicreaction. Thus advances in the understanding of heat transfer and fluid flow distribution continue to be crucial in achieving improved performance, efficiency and safety in microstructured reactors used for different applications. This paper presents a review of the experimental and numerical results on fluid flow distribution, heat transfer and combination thereof, available in the open literature. Heat transfer in microchannels can be suitably described by standard theory and correlations, but scaling effects (entrance effects, conjugate heat transfer, viscous heating, and temperature-dependent properties) have often to be accounted for in microsystems. Experiments with single channels are in good agreement with predictions from the published correlations. The accuracy of multichannel experiments is lower due to flow maldistribution. Special attention is devoted to theoretical and experimental studies on the effect of a flow maldistribution on the thermal and conversion response of catalytic microreactors. There view concludes with a set of design recommendations aimed at improving the reactor performance. (C) 2010 Elsevier Ltd. All rights reserved.