225 resultados para radio range


Relevância:

20.00% 20.00%

Publicador:

Resumo:

Changes of the electron dynamics during the mode transition (E- to H-mode) in a hydrogen radio-frequency (rf) inductively coupled plasma are investigated using space and phase resolved optical emission spectroscopy. The E- mode is characterized through relatively weak optical emission which is strongly modulated on a nanosecond time scale during the rf-cycle, with one pronounced maximum per cycle. The modulation in H-mode, with twice the rf-frequency, is significantly weaker while the emission intensities are about two orders of magnitude higher. In particular the transition between these two modes is studied under variations of rf-power input and gas pressure. Characteristic spatio-temporal structures are observed and can be understood in the frame of a simple model combining both coupling mechanisms in the transition regime.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

We have operated 25-100 mu m diameter radio frequency microhollow cathode discharges stably, for many hours, in neon and in argon. Electrical and spectroscopic measurements were used to explore three possible electron heating modes and obtain detail regarding the electron energy distribution. Analysis points to the possibility of pendular electron heating at low voltages.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

An extension of the Ye and Shreeve group contribution method [C. Ye, J.M. Shreeve, J. Phys. Chem. A 111 (2007) 1456–1461] for the estimation of densities of ionic liquids (ILs) is here proposed. The new version here presented allows the estimation of densities of ionic liquids in wide ranges of temperature and pressure using the previously proposed parameter table. Coefficients of new density correlation proposed were estimated using experimental densities of nine imidazolium-based ionic liquids. The new density correlation was tested against experimental densities available in literature for ionic liquids based on imidazolium, pyridinium, pyrrolidinium and phosphonium cations. Predicted densities are in good agreement with experimental literature data in a wide range of temperatures (273.15–393.15 K) and pressures (0.10–100 MPa). For imidazolium-based ILs, the mean percent deviation (MPD) is 0.45% and 1.49% for phosphonium-based ILs. A low MPD ranging from 0.41% to 1.57% was also observed for pyridinium and pyrrolidinium-based ILs.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

This letter reports the statistical characterization and modeling of the indoor radio channel for a mobile wireless personal area network operating at 868 MHz. Line of sight (LOS) and non-LOS conditions were considered for three environments: anechoic chamber, open office area and hallway. Overall, the Nakagami-m cdf best described fading for bodyworn operation in 60% of all measured channels in anechoic chamber and open office area environments. The Nakagami distribution was also found to provide a good description of Rician distributed channels which predominated in the hallway. Multipath played an important role in channel statistics with the mean recorded m value being reduced from 7.8 in the anechoic chamber to 1.3 in both the open office area and hallway.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Indoor wireless network based client localisation requires the use of a radio map to relate received signal strength to specific locations. However, signal strength measurements are time consuming, expensive and usually require unrestricted access to all parts of the building concerned. An obvious option for circumventing this difficulty is to estimate the radio map using a propagation model. This paper compares the effect of measured and simulated radio maps on the accuracy of two different methods of wireless network based localisation. The results presented indicate that, although the propagation model used underestimated the signal strength by up to 15 dB at certain locations, there was not a signigicant reduction in localisation performance. In general, the difference in performance between the simulated and measured radio maps was around a 30 % increase in rms error

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Power deposition in the head of a user wearing metal-framed spectacles was calculated with a 450 MHz personal radio transmitting in close proximity. Peak tissue SAR in the head depended on lens shape whether circular half-rim or rectangular with 70 and 174% increases, respectively, compared to the spectacle-free case. However, localised screening occurred with square frames, with a 40% reduction of peak SAR in the eye closest to the antenna.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The electron dynamics in the low-pressure operation regime ($«$ 5 Pa) of a neon capacitively coupled plasma is investigated using phase-resolved optical emission spectroscopy. Plasma ionization and sustainment mechanisms are governed by the expanding and contracting sheath and complex wave–particle interactions. Electrons are energized through the advancing and retreating electric field of the RF sheath. The associated interaction of energetic sheath electrons with thermal bulk plasma electrons drives a two-stream instability also dissipating power in the plasma.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Plasma ionization in the low-pressure operation regime ( $«$ 5 Pa) of RF capacitively coupled plasmas (CCPs) is governed by a complex interplay of various mechanisms, such as field reversal, sheath expansion, and wave–particle interactions. In a previous paper, it was shown that experimental observations in a hydrogen CCP operated at 13.56 MHz are qualitatively well described in a 1-D symmetrical particle-in-cell (PIC) simulation. In this paper, a spherical asymmetrical PIC simulation that is closer to the conditions of the highly asymmetrical experimental device is used to simulate a low-pressure neon CCP operated at 2 MHz. The results show a similar behavior, with pronounced ionization through field reversal, sheath expansion, and wave–particle interactions, and can be exploited for more accurate quantitative comparisons with experimental observations.