89 resultados para ovulation induction
Resumo:
The induction and rejoining of radiation-induced double-strand breaks (DSBs) in cells of six bladder tumor cell lines (T24, UM-UC3, TCC-SUP, RT112, J82, HT1376) were measured using the neutral comet assay. Radiation dose-response curves (0-60 Gy) showed damage (measured as mean tail moment) for five of the cell lines in the same rank order as cell survival (measured over 0-10 Gy), with the least damage in the most radioresistant cell line. Damage induction correlated well with clonogenic survival at high doses (SF10) for all six cell lines. At the clinically relevant dose of 2 Gy, correlation was good for four cell lines but poor for two (TCC-SUP and T24), The rejoining process had a fast and slow component for all cell lines. The rate of these two components of DNA repair did not correlate with cell survival. However, the time taken to reduce the amount of DNA damage to preirradiated control levels correlated positively with cell survival at 10 Gy but not 2 Gy; radioresistant cells rejoined the induced DSBs to preirradiation control levels more quickly than the radiosensitive cells. Although the results show good correlation between SF10 and DSBs for all six cell lines, the lack of correlation with SF2 for TCC-SUP and T24 cells would suggest that a predictive test should be carried out at the clinically relevant dose. At present the neutral comet assay cannot achieve this. (C) 2000 by Radiation Research Society.
Resumo:
This paper presents a predictive current control strategy for doubly-fed induction generators (DFIG). The method predicts the DFIG’s rotor current variations in the synchronous reference frame fixed to the stator flux within a fixed sampling period. This is then used to directly calculate the required rotor voltage to eliminate the current errors at the end of the following sampling period. Space vector modulation is used to generate the required switching pulses within the fixed sampling period. The impact of sampling delay on the accuracy of the sampled rotor current is analyzed and detailed compensation methods are proposed to improve the current control accuracy and system stability. Experimental results for a 1.5 kW DFIG system illustrate the effectiveness and robustness of the proposed control strategy during rotor current steps and rotating speed variation. Tests during negative sequence current injection further demonstrate the excellent dynamic performance of the proposed PCC method.
Resumo:
Relevance theory (Sperber & Wilson. 1995) suggests that people expend cognitive effort when processing information in proportion to the cognitive effects to be gained from doing so. This theory has been used to explain how people apply their knowledge appropriately when evaluating category-based inductive arguments (Medin, Coley, Storms, & Hayes, 2003). In such arguments, people are told that a property is true of premise categories and are asked to evaluate the likelihood that it is also true of conclusion categories. According to the relevance framework, reasoners generate hypotheses about the relevant relation between the categories in the argument. We reasoned that premises inconsistent with early hypotheses about the relevant relation would have greater effects than consistent premises. We designed three premise garden-path arguments where the same 3rd premise was either consistent or inconsistent with likely hypotheses about the relevant relation. In Experiments 1 and 2, we showed that effort expended processing consistent premises (measured via reading times) was significantly less than effort expended on inconsistent premises. In Experiment 2 and 3, we demonstrated a direct relation between cognitive effect and cognitive effort. For garden-path arguments, belief change given inconsistent 3rd premises was significantly correlated with Premise 3 (Experiment 3) and conclusion (Experiments 2 and 3) reading times. For consistent arguments, the correlation between belief change and reading times did not approach significance. These results support the relevance framework for induction but are difficult to accommodate under other approaches.
Resumo:
The Hoxa9 and Meis1 genes represent important oncogenic collaborators activated in a significant proportion of human leukemias with genetic alterations in the MLL gene. In this study, we show that the transforming property of Meis1 is modulated by 3 conserved domains, namely the Pbx interaction motif (PIM), the homeodomain, and the C-terminal region recently described to possess transactivating properties. Meis1 and Pbx1 interaction domain-swapping mutants are dysfunctional separately, but restore the full oncogenic activity of Meis1 when cotransduced in primary cells engineered to overexpress Hoxa9, thus implying a modular nature for PIM in Meis1-accelerated transformation. Moreover, we show that the transactivating domain of VP16 can restore, and even enhance, the oncogenic potential of the Meis1 mutant lacking the C-terminal 49 amino acids. In contrast to Meis1, the fusion VP16-Meis1 is spontaneously oncogenic, and all leukemias harbor genetic activation of endogenous Hoxa9 and/or Hoxa7, suggesting that Hoxa gene activation represents a key event required for the oncogenic activity of VP16-Meis1.
Resumo:
This paper outlines the use of phasor measurement unit (PMU) records to validate models of fixed speed induction generator (FSIG)-based wind farms during frequency transients. Wind turbine manufacturers usually create their own proprietary models which they can supply to power system utilities for stability studies, subject to confidentiality agreements. However, it is desirable to confirm the accuracy of supplied models with measurements from the particular installation, in order to assess their validity under real field conditions. This is prudent due to possible changes in control algorithms and design retrofits, not accurately reflected or omitted in the supplied model. One important aspect of such models, especially for smaller power systems with limited inertia, is their accuracy during system frequency transients. This paper, therefore, assesses the accuracy of FSIG models with regard to frequency stability, and hence validates a subset of the model dynamics. Such models can then be used with confidence to assess wider system stability implications. The measured and simulated response of a wind farm using doubly fed induction generator (DFIG) technology is also assessed.
Resumo:
Hypoxia results in adaptive changes in the transcription of a range of genes including erythropoietin. An important mediator is hypoxia-inducible factor-1 (HIF-1), a DNA binding complex shown to contain at least two basic helix-loop-helix PAS-domain (bHLH-PAS) proteins, HIF-1 alpha and aryl hydrocarbon nuclear receptor translocator (ARNT), In response to hypoxia, HIF-1 alpha is activated and accumulates rapidly in the cell. Endothelial PAS domain protein 1 (EPAS-1) is a recently identified bHLH-PAS protein with 48% identity to HIF-1 alpha, raising the question of its role in responses to hypoxia. We developed specific antibodies and studied expression and regulation of EPAS-1 mRNA and protein across a range of human cell lines. EPAS-1 was widely expressed, and strongly induced by hypoxia at the level of protein but not mRNA. Comparison of the effect of a range of activating and inhibitory stimuli showed striking similarities in the EPAS-1 and HIF-1 alpha responses. Although major differences were observed in the abundance of EPAS-1 and HIF-1 alpha in different cell types, differences in the inducible response were subtle with EPAS-1 protein being slightly more evident in normoxic and mildly hypoxic cells. Functional studies in a mutant cell line (Ka13) expressing neither HIF-1 alpha nor EPAS-1 confirmed that both proteins interact with hypoxically responsive targets, but suggest target specificity with greater EPAS-1 transactivation (relative to HIF-1 alpha transactivation) of the VEGF promoter than the LDH-A promoter. (C) 1998 by The American Society of Hematology.
Resumo:
Steroids form a structurally closely related group. As a result, antibodies produced for use in immunoassays regularly show unwanted cross-reactivities, These may be reduced by altering hapten-protein coupling procedures, thereby reducing the exposure of the determinants giving rise to the undesirable cross-reaction. However, these procedures carl prove to be complex, expensive and nor totally predictable in outcome. Exploitation of the clonal selection theory is an attractive alternative approach. The host is primed with the interfering cross-reactant coupled to a non-immunogenic amino acid copolymer to inactivate the B-lymphocyte clones specific for this steroid, producing a specific immunotolerance. Then, 3 days Inter, the host is immunized with the steroid against which nn antibody is required. The clones producing antibody to this immunogen are unaffected and the cross-reactivity is significantly reduced or deleted The technique has been applied to the reduction of endogenous sex steroid cross-reactivity from antibodies prepared against synthetic and semi-synthetic androgens (17 alpha-methyltestosterone, 19-nor-beta-testosterone) and the progestogen medroxyprogesterone. Antibodies prepared against the synthetic oestrogen zeranol using this technique have significantly reduced its undesirable cross-reactivity with the fungal metabolite 7 alpha-zearalenol. Highly specific antisera have been generated in all cases, the only adverse effect being a reduction in the titres achieved in comparison with rabbits receiving the conventional immunizing regime.