95 resultados para micellar electrokinetic capillary chromatography


Relevância:

20.00% 20.00%

Publicador:

Resumo:

A range of malts, as well as their high- and low-molecular-mass fractions, has been examined by capillary electrophoresis in phosphate buffer, pH 2.5, and in carbonate buffer, pH 9.5, and the results have been compared with those for roasted barley and for caramels. The malts fall into two categories: (i) the lightly roasted malts, where the high-molecular-mass coloured fraction is negatively charged at pH 9.5 and positively charged at pH 2.5; and (ii) the highly roasted malts (and the roasted barley), where the high-molecular-mass fraction migrates close to the electro-osmotic flow at both pH 9.5 and 2.5, implying that it carries little or no charge. The former category shows migration patterns similar to Class III caramels, whereas the latter migrates differently from Class I, III and IV caramels as well as from the former. Capillary electrophoresis therefore has considerable potential for differentiating between malts and between malts and caramels and roasted barley. (C) 2002 Society of Chemical Industry.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The determination of chloride impurities in ionic liquids using ion chromatography is described. A wide range of cation-anion combinations may be analyzed using ion chromatography, including water-immiscible ionic liquids. For all ionic liquids studied, the limit of quantification for chloride was found to be below 8 ppm.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Hi-fi mapping: Multiplexing fluorescent sensors that simultaneously target proton concentration and polarity move to micellar nanospaces, self-regulate their positions, and report their pKa values and wavelengths, which are controlled by their local environments. Such sensory functions enable maps of proton gradients near micellar membranes to be drawn.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

A new method for catalyst deposition on the inner walls of capillary microreactors is proposed which allows exact control of the coating thickness, pore size of the support, metal particle size, and metal loading. The wall-coated microreactors have been tested in a selective hydrogenation reaction. Activity and selectivity reach values close to those obtained with a homogeneous Pd catalyst. The catalyst activity was stable for a period of 1000 h time-on-stream.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

A rapid liquid chromatographic-tandem mass spectrometric (LC-MS/MS) multi-residue method for the simultaneous quantitation and identification of sixteen synthetic growth promoters and bisphenol A in bovine milk has been developed and validated. Sample preparation was straightforward, efficient and economically advantageous. Milk was extracted with acetonitrile followed by phase separation with NaCl. After centrifugation, the extract was purified by dispersive solid-phase extraction with C18 sorbent material. The compounds were analysed by reversed-phase LC-MS/MS using both positive and negative ionization and operated in multiple reaction monitoring (MRM) mode, acquiring two diagnostic product ions from each of the chosen precursor ions for unambiguous confirmation. Total chromatographic run time was less than 10 min for each sample. The method was validated at a level of 1 mu g L-1. A wide variety of deuterated internal standards were used to improve method performance. The accuracy and precision of the method were satisfactory for all analytes. The confirmative quantitative liquid chromatographic tandem mass spectrometric (LC-MS/MS) method was validated according to Commission Decision 2002/657/EC. The decision limit (CC alpha) and the detection capability (CC beta) were found to be below the chosen validation level of 1 mu g L-1 for all compounds. (C) 2010 Elsevier B.V. All rights reserved.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The potential for coupling technologies to deliver new, improved forms of bioanalysis is still in its infancy. We review a number of examples in which coupling has been successful, with special emphasis on combining surface-plasmon-resonance biosensors with mass spectrometry. We give an overview of current progress towards combining biosensor-based bioanalysis with chemical analysis for confirmation of paralytic shellfish poisons that are marine toxins. This comprehensive approach could be an alternative to the official methods currently used (e.g., animal testing and high-performance liquid chromatography with fluorescence detection) and could serve as a model for many more such applications. (C) 2009 Elsevier Ltd. All rights reserved.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

A rapid and sensitive immuno-based screening method was developed to detect domoic acid (DA) present in extracts of shellfish species using a surface plasmon resonance-based optical biosensor. A rabbit polyclonal antibody raised against DA was mixed with standard or sample extracts and allowed to interact with DA immobilized onto a sensor chip surface. The characterization of the antibody strongly suggested high cross-reactivity with DA and important isomers of the toxin. The binding of this antibody to the sensor chip surface was inhibited in the presence of DA in either standard solutions or sample extracts. The DA chip surface proved to be highly stable, achieving approximately 800 analyses per chip without any loss of surface activity. A single analytical cycle (sample injection, chip regeneration, and system wash) took 10 min to complete. Sample analysis (scallops, mussels, cockles, oysters) was achieved by simple extraction with methanol. These extracts were then filtered and diluted before analysis. Detection limits in the ng/g range were achieved by the assay; however, the assay parameters chosen allowed the test to be performed most accurately at the European Union's official action limit for DA of 20 mu g/g. At this concentration, intra- and interassay variations were measured for a range of shellfish species and ranged from 4.5 to 7.4% and 2.3 to 9.7%, respectively.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Screening for residues of anabolic steroids frequently requires extraction from tissues and fluids before analysis. Chemical procedures for these extractions can be complicated, expensive to perform and not ideal for the simultaneous extraction of analytes with different solubilities. Extraction by multi-immunoaffinity chromatography (MIAC) may be used as an alternative. Samples are passed through a column containing a range of antibodies immobilized on an inert support. The desired analytes are bound to their respective antibodies, washed and then eluted by a suitable solvent. The purified extracts can then be incorporated into the analytical tests, The analytes that can be extracted presently are alpha-nortestosterone, zeranol, trenbolone, diethylstilboestrol, boldenone and dexamethasone. Manually, the MIAC procedure is limited to about six columns per operator but bq automating the process using a robotic sample processor (RSP), 48 columns can be run simultaneously during the day or night. The RSP has also been adapted to transfer extracts and reagents on to ELISA plates. The automated system has proved to be a robust and reliable means of screening large numbers of samples for anabolic agents with minimal manual input

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Measurement of steroid esters in bovine hair samples, using sensitive liquid chromatography-tandem mass spectrometry (LC-MS/MS), provides a powerful tool for identifying animals treated illicitly with growth promoters. The successful application of such testing requires appropriate sampling of hair from treated animals. This paper describes the results of hair analysis by LC-MS/MS for two animal studies in which animals were treated with estradiol-3-benzoate and nortestosterone decanoate. The results from the first animal study indicate that animals treated with these anabolic steroids may not always be identified from analysis of hair samples; positive test results occur sporadically and only for some of the treated animals. The results from the second animal study identify conditions attaching to positive hair samples, such as, that concentrations of steroid esters in hair are related to distance of sampling from point of injection and to time post-treatment, that concentrations of steroid esters in hair are related to dose given to the animal but that this relationship may vary over time post-treatment, and that steroid esters may be measured in regrowth hair taken some weeks after treatment. Steroid esters are determined along the length of the hair, confirming that accumulation of steroid esters into hair occurs from various sources, including blood, sweat and sebum. The reported research provides some useful insights into the mechanisms governing the persistence of steroid esters in bovine hair following illicit treatment with growth promoters. (C) 2009 Elsevier B.V. All rights reserved.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Microsatellite instability (MSI) is a characteristic molecular phenotype of tumors from the hereditary nonpolyposis colorectal cancer (Lynch) syndrome. Routine MSI screening of tumors in patients is an efficient prescreening tool for the population-based detection of Lynch syndrome in the absence of family cancer history. We describe here the optimization of a denaturing high performance liquid chromatography (DHPLC) assay for MSI analysis with the