46 resultados para fungus chamber
Resumo:
• Differential resistance to arsenate (AsO4 3-) is demonstrated here among populations of the ericoid mycorrhizal fungus Hymenoscyphus ericae isolated from Calluna vulgaris in natural heathland soils and soils contaminated with AsO4 3-. • Isolates (c. 25) of the fungus from each of two As and Cu mine sites, and a natural heathland site, were screened for AsO4 3- and Cu2+ resistance by growing isolates in media containing a range of AsO4 3- and Cu2+ concentrations. • H. ericae populations from the mine sites demonstrated resistance to AsO4 3- compared with the heathland population; the mine-site populations producing significant growth at the highest AsO4 3- concentration (4.67 mol m-3), whereas growth of the heathland population was almost completely inhibited. EC50 values for mine-site isolates were estimated to be 5-41-times higher than the heathland population. All isolates produced identical responses to increasing Cu2+ concentrations, with no differences observed between mine-site and heathland isolates. • Populations of H. ericae on the contaminated mine sites have developed adaptive resistance to AsO4 3-. By contrast, Cu2+ resistance appears to be constitutive.
Resumo:
Variation in the abilities of 35 isolates of the ericoid mycorrhizal fungal endophyte Hymenoscyphus ericae from two field sites to utilise inorganic and organic nitrogen sources in axenic culture has been investigated. While most isolates showed a preference for NH4/- as a sole nitrogen source, considerable variation was observed in the abilities of isolates to utilise amino acids and protein (BSA). In particular, large intraspecific variation was observed for glutamine and BSA utilisation, with some isolates thriving on these substrates while others produced little growth. The data suggest that individual isolates of H. ericae may vary considerably in their abilities to supply their host plants with nitrogen from different substrates in soil. (C) 2000 Elsevier Science Ltd.
Resumo:
The effects of Cd and Zn on cross-colonization by Paxillus involutus of Scots pine seedlings was examined by using pairs of ectomycorrhizal (ECM) and non-mycorrhizal (NM) seedlings grown in the same vessel. This was done to assess, first, the ability of P. involutus to colonize NM Scots pine seedlings by growth from colonized roots of other Scots pine seedlings in the presence of Cd or Zn, and, second whether ECM colonization of Scots pine by P. involutus provided a competitive advantage over NM seedlings. Ectomycorrhizal colonization of Scots pine was shown to be more sensitive than Scots pine itself to Cd and Zn, but prior colonization did provide a competitive advantage with respect to biomass production. This beneficial effect over NM seedlings was, however, equal in the control, Cd and Zn treatments, and was due simply to growth stimulation in the presence of ECM colonization. Cross-colonization from an ECM to a NM seedling was reduced but not prevented by Cd and Zn. Cd had a more negative effect on cross-colonization than on initial colonization of seedlings, whereas Zn had an equally inhibitory effect on both parameters. These results have important implications for plant establishment on metal-contaminated sites. If cross-colonization between plants is reduced by toxic metals, plant establishment on contaminated sites might be retarded.
Resumo:
High-affinity nitrate transport was examined in intact hyphae of Neurospora crassa using electrophysiological recordings to characterize the response of the plasma membrane to NO3 - challenge and to quantify transport activity. The NO3 --associated membrane current was determined using a three electrode voltage clamp to bring membrane voltage under experimental control and to compensate for current dissipation along the longitudinal cell axis. Nitrate transport was evident in hyphae transferred to NO3 --free, N-limited medium for 15 hr, and in hyphae grown in the absence of a nitrogen source after a single 2-min exposure to 100 μM NO3 -. In the latter, induction showed a latency of 40-80 min and rose in scalar fashion with full transport activity mensurable approx. 100 min after first exposure to NO3 -; it was marked by the appearance of a pronounced sensitivity of membrane voltage to extracellular NO3 - additions which, after induction, resulted in reversible membrane depolarizations of (+)54-85 mV in the presence of 50 μM NO3 -; and it was suppressed when NH4 +, was present during the first, inductive exposure to NO3 -. Voltage clamp measurements carried out immediately before and following NO3 - additions showed that the NO3 --evoked depolarizations were the consequence of an inward-directed current that appeared in parallel with the depolarizations across the entire range of accessible voltages -400 to +100 mV). Measurements of NO3 - uptake using NO3 --selective macroelectrodes indicated a charge stoichiometry for NO3 - transport of 1(+):1(NO3 -) with common K(m) and J(max) values around 25 μM and 75 pmol NO3 - cm-2sec-1, respectively, and combined measurements of pH(o) and [NO3 -](o) showed a net uptake of approx. 1 H+ with each NO3 - anion. Analysis of the NO3 - current demonstrated a pronounced voltage sensitivity within the normal physiological range between -300 and -100 mV as well as interactions between the kinetic parameters of membrane voltage, pH(o) and [NO3 -](o). Increasing the bathing pH from 5.5 to 8.0 reduced the current and the associated membrane depolarizations 2- to 4-fold. At a constant pH(o) of 6.1, driving the membrane voltage from -350 to -150 mV resulted in an approx. 3-fold reduction in the maximum current and a 5-fold rise in the apparent affinity for NO3 -. By contrast, the same depolarization effected an approx. 20% fall in the K(m) for transport as a function in [H+](o). These, and additional results are consistent with a charge-coupling stoichiometry of 2(H+) per NO anion transported across the membrane, and implicate a carrier cycle in which NO binding is kinetically adjacent to the rate-limiting step of membrane charge transit. The data concur with previous studies demonstrating a pronounced voltage-dependence to high-affinity NO3 - transport system in Arabidopsis, and underline the importance of voltage as a kinetic factor controlling NO3 - transport; finally, they distinguish metabolite repression of NO3 - transport induction from its sensitivity to metabolic blockade and competition with the uptake of other substrates that draw on membrane voltage as a kinetic substrate.
Resumo:
Objective: To study the population distribution and longitudinal changes in anterior chamber angle width and its determinants among Chinese adults. Design: Prospective cohort, population-based study. Participants: Persons aged 35 years or more residing in Guangzhou, China, who had not previously undergone incisional or laser eye surgery. Methods: In December 2008 and December 2010, all subjects underwent automated keratometry, and a random 50% sample had anterior segment optical coherence tomography with measurement of angle-opening distance at 500 μm (AOD500), angle recess area (ARA), iris thickness at 750 μm (IT750), iris curvature, pupil diameter, corneal thickness, anterior chamber width (ACW), lens vault (LV), and lens thickness (LT) and measurement of axial length (AL) and anterior chamber depth (ACD) by partial coherence laser interferometry. Main Outcome Measures: Baseline and 2-year change in AOD500 and ARA in the right eye. Results: A total of 745 subjects were present for full biometric testing in both 2008 and 2010 (mean age at baseline, 52.2 years; standard deviation [SD], 11.5 years; 53.7% were female). Test completion rates in 2010 varied from 77.3% (AOD500: 576/745) to 100% (AL). Mean AOD500 decreased from 0.25 mm (SD, 0.13 mm) in 2008 to 0.21 mm (SD, 13 mm) in 2010 (difference, -0.04; 95% confidence interval [CI], -0.05 to -0.03). The ARA decreased from 21.5±3.73 10-2 mm2 to 21.0±3.64 10 -2 mm2 (difference, -0.46; 95% CI, -0.52 to -0.41). The decrease in both was most pronounced among younger subjects and those with baseline AOD500 in the widest quartile at baseline. The following baseline variables were significantly associated with a greater 2-year decrease in both AOD500 and ARA: deeper ACD, steeper iris curvature, smaller LV, greater ARA, and greater AOD500. By using simple regression models, we could explain 52% to 58% and 93% of variation in baseline AOD500 and ARA, respectively, but only 27% and 16% of variation in 2-year change in AOD500 and ARA, respectively. Conclusions: Younger persons and those with the least crowded anterior chambers at baseline have the largest 2-year decreases in AOD500 and ARA. The ability to predict change in angle width based on demographic and biometric factors is relatively poor, which may have implications for screening. Financial Disclosure(s): The author(s) have no proprietary or commercial interest in any materials discussed in this article. © 2012 American Academy of Ophthalmology.
Resumo:
OBJECTIVE:
To design a system of gonioscopy that will allow greater interobserver reliability and more clearly defined screening cutoffs for angle closure than current systems while being simple to teach and technologically appropriate for use in rural Asia, where the prevalence of angle-closure glaucoma is highest.
DESIGN:
Clinic-based validation and interobserver reliability trial.
PARTICIPANTS:
Study 1: 21 patients 18 years of age and older recruited from a university-based specialty glaucoma clinic; study 2: 32 patients 18 years of age and older recruited from the same clinic.
INTERVENTION:
In study 1, all participants underwent conventional gonioscopy by an experienced observer (GLS) using the Spaeth system and in the same eye also underwent Scheimpflug photography, ultrasonographic measurement of anterior chamber depth and axial length, automatic refraction, and biometric gonioscopy with measurement of the distance from iris insertion to Schwalbe's line using a reticule based in the slit-lamp ocular. In study 2, all participants underwent both conventional gonioscopy and biometric gonioscopy by an experienced gonioscopist (NGC) and a medical student with no previous training in gonioscopy (JK).
MAIN OUTCOME MEASURES:
Study 1: The association between biometric gonioscopy and conventional gonioscopy, Scheimpflug photography, and other factors known to correlate with the configuration of the angle. Study 2: Interobserver agreement using biometric gonioscopy compared to that obtained with conventional gonioscopy.
RESULTS:
In study 1, there was an independent, monotonic, statistically significant relationship between biometric gonioscopy and both Spaeth angle (P = 0.001, t test) and Spaeth insertion (P = 0.008, t test) grades. Biometric gonioscopy correctly identified six of six patients with occludable angles according to Spaeth criteria. Biometric gonioscopic grade was also significantly associated with the anterior chamber angle as measured by Scheimpflug photography (P = 0.005, t test). In study 2, the intraclass correlation coefficient between graders for biometric gonioscopy (0.97) was higher than for Spaeth angle grade (0.72) or Spaeth insertion grade (0.84).
CONCLUSION:
Biometric gonioscopy correlates well with other measures of the anterior chamber angle, shows a higher degree of interobserver reliability than conventional gonioscopy, and can readily be learned by an inexperienced observer.
Resumo:
AIM:
To utilise a novel method for making measurements in the anterior chamber in order to compare the anterior chamber angles of people of European, African, and east Asian descent aged 40 years and over.
METHODS:
A cross sectional study on 15 people of each sex from each decade from the 40s to the 70s, from each of three racial groups-black, white, and Chinese Singaporeans. Biometric gonioscopy (BG) utilises a slit lamp mounted reticule to make measurements from the apparent iris insertion to Schwalbe's line through a Goldmann one mirror goniolens. The main outcome measures were BG measurements of the anterior chamber angle as detailed above.
RESULTS:
There was no significant difference in angle measurement between black, white, and Chinese races in this study. However, at younger ages people of Chinese race appeared to have deeper angles than white or black people, whereas the angles of older Chinese were significantly narrower (p = 0.004 for the difference in slope of BG by age between Chinese and both black and white people).
CONCLUSION:
The failure to detect a difference in angle measurements between these groups was surprising, given the much higher prevalence of angle closure among Chinese. It appears that the overall apparent similarity of BG means between Chinese and Western populations may mask very different trends with age. The apparently more rapid decline in angle width measurements with age among Chinese may be due to the higher prevalence of cataract or "creeping angle closure." However, longitudinal inferences from cross sectional data are problematic, and this may represent a cohort phenomenon caused by the increasing prevalence of myopia in the younger Singaporean population.
Resumo:
BACKGROUND:
The prevalence of angle-closure glaucoma (ACG) is greater for Eskimos/Inuit than it is for any other ethnic group in the world. Although it has been suggested that this prevalence may be due to a population tendency toward shallower anterior chamber angles, available evidence for other populations such as Chinese with high rates of ACG has not consistently demonstrated such a tendency.
METHODS:
A reticule, slit-lamp, and standard Goldmann one-mirror goniolens were used to make measurements in the anterior chamber (AC) angle according to a previously reported protocol for biometric gonioscopy (BG) (Ophthalmology 1999;106:2161-7). Measurements were made in all four quadrants of one eye among 133 phakic Alaskan Eskimos aged 40 years and older. Automatic refraction, dilated examination of the anterior segment and optic nerve, and A-scan measurements of AC depth, lens thickness, and axial length were also carried out for all subjects.
RESULTS:
Both central and peripheral AC measurements for the Eskimo subjects were significantly lower than those previously reported by us for Chinese, blacks, and whites under the identical protocol. Eskimos also seemed to have somewhat more hyperopia. There were no differences in biometric measurements between men and women in this Eskimo population. Angle measurements by BG seemed to decline more rapidly over life among Eskimos and Chinese than blacks or whites. Although there was a significant apparent decrease in AC depth, increase in lens thickness, and increase in hyperopia with age among Eskimos, all of these trends seemed to reverse in the seventh decade and beyond.
CONCLUSIONS:
Eskimos do seem to have shallower ACs than do other racial groups. Measurements of the AC angle seem to decline more rapidly over life among Eskimos than among blacks or whites, a phenomenon also observed by us among Chinese, another group with high ACG prevalence. This apparent more rapid decline may be due to a cohort effect with higher prevalence of myopia and resulting wider angles among younger Eskimos and Chinese.
Resumo:
PURPOSE: To describe and evaluate a new method for measuring anterior chamber volume (ACV). DESIGN: Observational case series. METHODS: The authors measured ACV using the anterior chamber (AC) optical coherence tomographer (OCT) and applied image-processing software developed by them. Repeatability was evaluated. The ACV was measured in patient groups with normal ACs, shallow ACs, and deep ACs. The volume difference before and after laser peripheral iridotomy (LPI) was analyzed for the shallow and deep groups. RESULTS: Coefficients of repeatability for intraoperator, interoperator, and interimage measurements were 0.406%, 0.958%, and 0.851%, respectively. The limits of agreement for intraoperator and interoperator measurement were -0.911 microl to 1.343 microl and -7.875 microl to -2.463 microl, respectively. There were significant ACV differences in normal, shallow, and deep AC eyes (P < .001) and before and after LPI in shallow AC (P < .001) and deep AC (P = .008) eyes. CONCLUSIONS: The ACV values obtained by this method were repeatable and in accord with clinical observation.
Resumo:
In this study, the PTW 1000SRS array with Octavius 4D phantom was characterised for FF and FFF beams. MU linearity, field size, dose rate, dose per pulse (DPP) response and dynamic conformal arc treatment accuracy of the 1000SRS array were assessed for 6MV, 6FFF and 10FFF beams using a Varian TrueBeam STx linac. The measurements were compared with a pinpoint IC, microdiamond IC and EBT3 Gafchromic film. Measured dose profiles and FWHMs were compared with film measurements. Verification of FFF volumetric modulated arc therapy (VMAT) clinical plans were assessed using gamma analysis with 3%/3 mm and 2%/2 mm tolerances (10% threshold). To assess the effect of cross calibration dose rate, clinical plans with different dose rates were delivered and analysed. Output factors agreed with film measurements to within 4.5% for fields between 0.5 and 1 cm and within 2.7% for field sizes between 1.5 and 10 cm and were highly correlated with the microdiamond IC detector. Field sizes measured with the 1000SRS array were within 0.5 mm of film measurements. A drop in response of up to 1.8%, 2.4% and 5.2% for 6MV, 6FFF and 10FFF beams respectively was observed with increasing nominal dose rate. With an increase in DPP, a drop of up to 1.7%, 2.4% and 4.2% was observed in 6MV, 6FFF and 10FFF respectively. The differences in dose following dynamic conformal arc deliveries were less than 1% (all energies) from calculated. Delivered VMAT plans showed an average pass percentage of 99.5(±0.8)% and 98.4(±3.4)% with 2%/2 mm criteria for 6FFF and 10FFF respectively. A drop to 97.7(±2.2)% and 88.4(±9.6)% were observed for 6FFF and 10FFF respectively when plans were delivered at the minimum dose rate and calibrated at the maximum dose rate. Calibration using a beam with the average dose rate of the plan may be an efficient method to overcome the dose rate effects observed by the 1000SRS array.
Resumo:
A decree prohibiting the publication of any book considered to be contrary to statute, injunction, ordinance and letters patents, as well as banning the importation of such works. This provided the first occasion on which the proprietary interests of the Stationers' Company and the ideological control of the press become explicitly linked.
The commentary describes the background to the Decree and in particular the concern of Elizabeth's High Commission over the influx of Catholic texts from continental Europe. The commentary argues that the Decree is particularly significant in that it formalised, for the first time, the specific link between the interests of the government in regulating and censuring the press and the economic interests of the Stationers' Company. The formal inclusion of the category of ‘letters patents' within the remit of the Decree ensured that works published under a printing privilege now attracted the formal protection of the Star Chamber.
Resumo:
A decree prohibiting the publication of any book contrary to statute, injunction, ordinance and letters patents, as well as any ordinance set down by the Company of Stationers. The formal protection of the Star Chamber was extended not only to books protected under royal printing privileges (see: uk_1566) but to books printed in contravention of the internal regulations of the Stationers' Company itself, further enhancing the significance of ‘stationers' copyright'.
The commentary describes the background to the decree, in particular the religious controversies of the 1570s and 1580s, as well as the dissatisfaction within the general printing trade during this period at the manner in which a number of the printing privileges granted by Elizabeth resulted in the monopolistic control of commercially lucrative works within the hands of a few stationers only. The commentary also details the efforts of the dominant members of the Stationers' Company to influence the substance of the decree and further augment their control over the internal operation of the book trade.
Resumo:
A decree of the Star Chamber designed to regulate the printing of all literary works, whether ecclesiastical or secular in nature. The decree further entrenched the significance and validity of ‘stationers' copyright' in requiring that no work be printed without first being entered on the Company of Stationers' Register Book. The decree also provided that any materials printed thereafter were to carry both the name of the printer and the author of the work.
The commentary describes how, by comparison with earlier decrees (see: uk_1566; uk_1586), the 1637 Decree provided a more elaborate system for licensing both ecclesiastical and secular works as well as a more comprehensive set of regulations to govern the operation of the printing trade. As a regulatory measure, it is widely regarded as representing the high point of the Company of Stationers' control and authority over the book trade.
Resumo:
The aim of this work was to track and verify the delivery of respiratory-gated irradiations, performed with three versions of TrueBeam linac, using a novel phantom arrangement that combined the OCTAVIUS® SRS 1000 array with a moving platform. The platform was programmed to generate sinusoidal motion of the array. This motion was tracked using the real-time position management (RPM) system and four amplitude gating options were employed to interrupt MV beam delivery when the platform was not located within set limits. Time-resolved spatial information extracted from analysis of x-ray fluences measured by the array was compared to the programmed motion of the platform and to the trace recorded by the RPM system during the delivery of the x-ray field. Temporal data recorded by the phantom and the RPM system were validated against trajectory log files, recorded by the linac during the irradiation, as well as oscilloscope waveforms recorded from the linac target signal. Gamma analysis was employed to compare time-integrated 2D x-ray dose fluences with theoretical fluences derived from the probability density function for each of the gating settings applied, where gamma criteria of 2%/2 mm, 1%/1 mm and 0.5%/0.5 mm were used to evaluate the limitations of the RPM system. Excellent agreement was observed in the analysis of spatial information extracted from the SRS 1000 array measurements. Comparisons of the average platform position with the expected position indicated absolute deviations of <0.5 mm for all four gating settings. Differences were observed when comparing time-resolved beam-on data stored in the RPM files and trajectory logs to the true target signal waveforms. Trajectory log files underestimated the cycle time between consecutive beam-on windows by 10.0 ± 0.8 ms. All measured fluences achieved 100% pass-rates using gamma criteria of 2%/2 mm and 50% of the fluences achieved pass-rates >90% when criteria of 0.5%/0.5 mm were used. Results using this novel phantom arrangement indicate that the RPM system is capable of accurately gating x-ray exposure during the delivery of a fixed-field treatment beam.