51 resultados para external


Relevância:

20.00% 20.00%

Publicador:

Resumo:

This paper offers a new insight into how organizations engage with external complexity. It applies a political action perspective that draws attention to the hitherto neglected question of how the relative power organizational leaders enjoy within their environments is significant for the actions they can take on behalf of their organizations when faced with external complexity. It identifies cognitive and relational complexity as two dimensions of the environment with which organizations have to engage. It proposes three modes whereby organizations may engage with environmental complexity that are conditioned by an organization's power within its environment. It also considers the intention associated with each mode, as well as the implications of these modes of engagement for how an organization can learn about its environment and for the use of rationality and intuition in its strategic decision-making. The closing discussion considers how this analysis integrates complexity and political action perspectives in a way that contributes to theoretical development and provides the basis for a dynamic political co-evolutionary approach. © The Author(s) 2011.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Aiming to establish a rigorous link between macroscopic random motion (described e.g. by Langevin-type theories) and microscopic dynamics, we have undertaken a kinetic-theoretical study of the dynamics of a classical test-particle weakly coupled to a large heat-bath in thermal equilibrium. Both subsystems are subject to an external force field. From the (time-non-local) generalized master equation a Fokker-Planck-type equation follows as a "quasi-Markovian" approximation. The kinetic operator thus defined is shown to be ill-defined; in specific, it does not preserve the positivity of the test-particle distribution function f(x, v; t). Adopting an alternative approach, previously introduced for quantum open systems, is proposed to lead to a correct kinetic operator, which yields all the expected properties. A set of explicit expressions for the diffusion and drift coefficients are obtained, allowing for modelling macroscopic diffusion and dynamical friction phenomena, in terms of an external field and intrinsic physical parameters.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

OBJECTIVE: To assess the impedance cardiogram recorded by an automated external defibrillator during cardiac arrest to facilitate emergency care by lay persons. Lay persons are poor at emergency pulse checks (sensitivity 84%, specificity 36%); guidelines recommend they should not be performed. The impedance cardiogram (dZ/dt) is used to indicate stroke volume. Can an impedance cardiogram algorithm in a defibrillator determine rapidly circulatory arrest and facilitate prompt initiation of external cardiac massage?

DESIGN: Clinical study.

SETTING: University hospital.

PATIENTS: Phase 1 patients attended for myocardial perfusion imaging. Phase 2 patients were recruited during cardiac arrest. This group included nonarrest controls.

INTERVENTIONS: The impedance cardiogram was recorded through defibrillator/electrocardiographic pads oriented in the standard cardiac arrest position.

MEASUREMENTS AND MAIN RESULTS: Phase 1: Stroke volumes from gated myocardial perfusion imaging scans were correlated with parameters from the impedance cardiogram system (dZ/dt(max) and the peak amplitude of the Fast Fourier Transform of dZ/dt between 1.5 Hz and 4.5 Hz). Multivariate analysis was performed to fit stroke volumes from gated myocardial perfusion imaging scans with linear and quadratic terms for dZ/dt(max) and the Fast Fourier Transform to identify significant parameters for incorporation into a cardiac arrest diagnostic algorithm. The square of the peak amplitude of the Fast Fourier Transform of dZ/dt was the best predictor of reduction in stroke volumes from gated myocardial perfusion imaging scans (range = 33-85 mL; p = .016). Having established that the two pad impedance cardiogram system could detect differences in stroke volumes from gated myocardial perfusion imaging scans, we assessed its performance in diagnosing cardiac arrest. Phase 2: The impedance cardiogram was recorded in 132 "cardiac arrest" patients (53 training, 79 validation) and 97 controls (47 training, 50 validation): the diagnostic algorithm indicated cardiac arrest with sensitivities and specificities (+/- exact 95% confidence intervals) of 89.1% (85.4-92.1) and 99.6% (99.4-99.7; training) and 81.1% (77.6-84.3) and 97% (96.7-97.4; validation).

CONCLUSIONS: The impedance cardiogram algorithm is a significant marker of circulatory collapse. Automated defibrillators with an integrated impedance cardiogram could improve emergency care by lay persons, enabling rapid and appropriate initiation of external cardiac massage.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Key stakeholders in the UK charity sector have, in recent years, advocated greater accountability for charity performance. Part of that debate has focussed on the use of conversion ratios as indicators of efficiency, with importance to stakeholders being contrasted with charities’ apparent reluctance to report such measures. Whilst, before 2005, conversion ratios could have been computed from financial statements, changes in the UK charity SORP have radically altered the ability of users to do this. This article explores the impact on the visibility of such information through an analysis of the financial statements of large UK charities before and after the 2005 changes. Overall, the findings suggest that, despite the stated intention of increasing transparency in respect of charity costs, the application of the changes has resulted in charities ‘managing’ the numbers and limiting their disclosures, possibly to the detriment of external stakeholders.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

In recent years external beam radiotherapy (EBRT) has been proposed as a treatment for the wet form of age-related macular degeneration (AMD) where choroidal neovascularization (CNV) is the hallmark. While the majority of pilot (Phase I) studies have reported encouraging results, a few have found no benefit, i.e. EBRT was not found to result in either improvement or stabilization of visual acuity of the treated eye. The natural history of visual loss in untreated CNV of AMD is highly variable. Loss of vision is influenced mainly by the presenting acuity, and size and composition of the lesion, and to a lesser extent by a variety of other factors. Thus the variable outcome reported by the small Phase I studies of EBRT published to date may simply reflect the variation in baseline factors. We therefore obtained information on 409 patients treated with EBRT from eight independent centres, which included details of visual acuity at baseline and at subsequent follow-up visits. Analysis of the data showed that 22.5% and 14.9% of EBRT-treated eyes developed moderate and severe loss of vision, respectively, during an average follow-up of 13 months. Initial visual acuity, which explained 20.5% of the variation in visual loss, was the most important baseline factor studied. Statistically significant differences in loss of vision were observed between centres, after considering the effects of case mix factors. Comparisons with historical data suggested that while moderate visual loss was similar to that of the natural history of the disease, the likelihood of suffering severe visual loss was halved. However, the benefit in terms of maintained/improved vision in the treated eye was modest.

Relevância:

20.00% 20.00%

Publicador:

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Purpose: To evaluate the clinical and histological side effects of a prototype stereotactic radiotherapy system delivering microcollimated external beam radiation through pars plana in porcine eyes.

Methods: Five Yucatan mini-swine (10 eyes) were randomized to five treatment groups. Eight eyes were dosed with X-ray radiation on Day 1, and two eyes served as untreated controls. Treated eyes received doses up to 60 Gy to the retina and up to 130 Gy to the sclera using single or overlapping beams. The treatment beams were highly collimated such that the diameter was approximately 2.5 mm on the sclera and 3 mm on the retinal surface. Fundus photography, fluorescein angiography (FA), and spectral domain optical coherence tomography (SD-OCT) were obtained on days 7, 30, 60, and 110. Images were examined by a masked grader and evaluated for abnormalities. Animals were sacrificed on day 111 and gross and histopathological analysis was conducted.

Results: Histological and gross changes to eye structures including conjunctiva and lens were minimal at all doses. Fundus, FA, and SD-OCT of the targeted region failed to disclose any abnormality in the control or 21 Gy treated animals. In the 42 and 60 Gy animals, hypopigmented spots were noted after treatment on clinical exam, and corresponding hyperfluorescent staining was seen in late frames. No evidence of choroidal hypoperfusion was seen. The histological specimens from the 60 Gy animals showed photoreceptor loss and displacement of cone nuclei.

Conclusion: Transcleral stereotactic radiation dosing in porcine eyes can be accomplished with no significant adverse events as doses less than 42 Gy.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

To independently evaluate and compare the performance of the Ocular Hypertension Treatment Study-European Glaucoma Prevention Study (OHTS-EGPS) prediction equation for estimating the 5-year risk of open-angle glaucoma (OAG) in four cohorts of adults with ocular hypertension.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

A softened strut-and-tie macro model able to reproduce the flexural behaviour of
external beam-column joint is presented. The model is specific for concrete with hooked steel fibres (FRC) and it is designed to calculate the flexural response, as load-deflection curve, of a beam-column sub-assemblages. The model considers the presence of a constant vertical load acting on the column and of a monotonically increasing lateral force applied at the tip of the beam.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

To test the applicability of the sex-specific 2008 Framingham general cardiovascular risk equation for coronary heart disease (CHD) and stroke in European middle-aged men from Ireland and France.