Resumo:
OBJECTIVE: This study was designed to record the dietary habits of patients undergoing methadone therapy.
BACKGROUND: Numerous studies report that patients undergoing methadone treatment present with high levels of oral disease, especially dental caries. A number of factors have been described to account for this: sugared methadone preparations, prolonged oral retention, associated xerostomia and poor diet.
METHODS: A cross-sectional descriptive study using survey methodology was conducted of patients attending a non-resident drug rehabilitation clinic. A self-completion questionnaire and diet diary were developed and distributed to 66 patients over an 8 week period.
RESULTS: Of the 66 questionnaires distributed, 52 were successfully completed giving a response rate of 79%. 6 patients declined to complete the questionnaire. The surveyed patient pool consisted of 32 females (62%) and 20 males (38%) with a mean age of 32 years. All the participants were taking a prescribed daily dose of methadone when questioned. 68% of respondents consumed convience foods or sugary snacks every day. Of those patients who drank tea or coffee daily, 84% added sugar and 54% added 3 teaspoons or more. The majority of patients (71%) consumed at least one glass of a fizzy soft drink daily. In addition, the majority of respondents indicated that they snacked regularly between meals and 24% stated that they often woke up during the night for a snack. Patients recorded their last intake of food ranging from 5pm to 3am.
CONCLUSIONS: The patients surveyed had poor dietary habits. Respondents consumed a large amount of convience foods and sugars during mealtimes and through regular snacking. Dietary counselling should be considered as part of treatment for patients undergoing methadone therapy.
Resumo:
Background
The aim of this position statement was to inform the choice of physical activity tools for use within CF research and clinical settings.
Methods
A systematic review of physical activity tools to explore evidence for reliability, validity, and responsiveness. Narrative answers to “four key questions” on motion sensors, questionnaires and diaries were drafted by the core writing team and then discussed at the Exercise Working Group in ECFS Lisbon 2013.
Results and summary
Our current position is that activity monitors such as SenseWear or ActiGraph offer informed choices to facilitate a comprehensive assessment of physical activity, and should as a minimum report on dimensions of physical activity including energy expenditure, step count and time spent in different intensities and sedentary time. The DigiWalker pedometer offers an informed choice of a comparatively inexpensive method of obtaining some measurement of physical activity. The HAES represents an informed choice of questionnaire to assess physical activity. There is insufficient data to recommend the use of one diary over another. Future research should focus on providing additional evidence of clinimetric properties of these and new physical activity assessment tools, as well as further exploring the added value of physical activity assessment in CF.
Resumo:
There is a significant lack of indoor air quality research in low energy homes. This study compared the indoor air quality of eight
newly built case study homes constructed to similar levels of air-tightness and insulation; with two different ventilation strategies (four homes with Mechanical Ventilation with Heat Recovery (MVHR) systems/Code level 4 and four homes naturally ventilated/Code level 3). Indoor air quality measurements were conducted over a 24 h period in the living room and main bedroom of each home during the summer and winter seasons. Simultaneous outside measurements and an occupant diary were also employed during the measurement period. Occupant interviews were conducted to gain information on perceived indoor air quality, occupant behaviour and building related illnesses. Knowledge of the MVHR system including ventilation related behaviour was also studied. Results suggest indoor air quality problems in both the mechanically ventilated and naturally ventilated homes, with significant issues identified regarding occupant use in the social homes