47 resultados para demand-control-support
Resumo:
HSDPA specifications include support for a flexible framework for QoS management. In this paper, it is shown how buffer management could be incorporated into HSDPA QoS framework for 'multimedia' traffic QoS control in the MAC-hs of the Node-B. A time-space-priority (TSP) scheme is proposed as viable buffer management scheme to this effect. Comparative simulation study with other schemes is presented, demonstrating the effectiveness of the TSP buffer management scheme for 'multimedia' service QoS control in HSDPA Node-B data buffers
Resumo:
This paper examines the ability of the doubly fed induction generator (DFIG) to deliver multiple reactive power objectives during variable wind conditions. The reactive power requirement is decomposed based on various control objectives (e.g. power factor control, voltage control, loss minimisation, and flicker mitigation) defined around different time frames (i.e. seconds, minutes, and hourly), and the control reference is generated by aggregating the individual reactive power requirement for each control strategy. A novel coordinated controller is implemented for the rotor-side converter and the grid-side converter considering their capability curves and illustrating that it can effectively utilise the aggregated DFIG reactive power capability for system performance enhancement. The performance of the multi-objective strategy is examined for a range of wind and network conditions, and it is shown that for the majority of the scenarios, more than 92% of the main control objective can be achieved while introducing the integrated flicker control scheme with the main reactive power control scheme. Therefore, optimal control coordination across the different control strategies can maximise the availability of ancillary services from DFIG-based wind farms without additional dynamic reactive power devices being installed in power networks.
Resumo:
Reactive power has become a vital resource in modern electricity networks due to increased penetration of distributed generation. This paper examines the extended reactive power capability of DFIGs to improve network stability and capability to manage network voltage profile during transient faults and dynamic operating conditions. A coordinated reactive power controller is designed by considering the reactive power capabilities of the rotor-side converter (RSC) and the grid-side converter (GSC) of the DFIG in order to maximise the reactive power support from DFIGs. The study has illustrated that, a significant reactive power contribution can be obtained from partially loaded DFIG wind farms for stability enhancement by using the proposed capability curve based reactive power controller; hence DFIG wind farms can function as vital dynamic reactive power resources for power utilities without commissioning additional dynamic reactive power devices. Several network adaptive droop control schemes are also proposed for network voltage management and their performance has been investigated during variable wind conditions. Furthermore, the influence of reactive power capability on network adaptive droop control strategies has been investigated and it has also been shown that enhanced reactive power capability of DFIGs can substantially improve the voltage control performance.
Resumo:
Anti-islanding protection is becoming increasingly important due to the rapid installation of distributed generation from renewable resources like wind, tidal and wave, solar PV, bio-fuels, as well as from other resources like diesel. Unintentional islanding presents a potential risk for damaging utility plants and equipment connected from the demand side, as well as to public and personnel in utility plants. This paper investigates automatic islanding detection. This is achieved by deploying a statistical process control approach for fault detection with the real-time data acquired through a wide area measurement system, which is based on Phasor Measurement Unit (PMU) technology. In particular, the principal component analysis (PCA) is used to project the data into principal component subspace and residual space, and two statistics are used to detect the occurrence of fault. Then a fault reconstruction method is used to identify the fault and its development over time. The proposed scheme has been used in a real system and the results have confirmed that the proposed method can correctly identify the fault and islanding site.
Resumo:
A low cost supercritical CO foaming rig with a novel design has been used to prepare fully interconnected and highly porous biodegradable scaffolds with controllable pore size and structure that can promote cancellous bone regeneration. Porous polymer scaffolds have been produced by plasticising the polymer with high pressure CO and by the formation of a porous structure following the escape of CO from the polymer. Although, control over pore size and structure has been previously reported as difficult with this process, the current study shows that control is possible. The effects of processing parameters such as CO saturation pressure, time and temperature and depressurisation rate on the morphological properties, namely porosity, pore interconnectivity, pore size and wall thickness- of the scaffolds have been investigated. Poly(d,l)lactic acid was used as the biodegradable polymer. The surfaces and internal morphologies of the poly(d,l)lactic acid scaffolds were examined using optical microscope and micro computed tomography. Preosteoblast human bone cells were seeded on the porous scaffolds in vitro to assess cell attachment and viability. The scaffolds showed a good support for cell attachment, and maintained cell viability throughout 7 days in culture. This study demonstrated that the morphology of the porous structure can be controlled by varying the foaming conditions, allowing the porous scaffolds to be used in various tissue engineering applications.
Resumo:
In semiconductor fabrication processes, effective management of maintenance operations is fundamental to decrease costs associated with failures and downtime. Predictive Maintenance (PdM) approaches, based on statistical methods and historical data, are becoming popular for their predictive capabilities and low (potentially zero) added costs. We present here a PdM module based on Support Vector Machines for prediction of integral type faults, that is, the kind of failures that happen due to machine usage and stress of equipment parts. The proposed module may also be employed as a health factor indicator. The module has been applied to a frequent maintenance problem in semiconductor manufacturing industry, namely the breaking of the filament in the ion-source of ion-implantation tools. The PdM has been tested on a real production dataset. © 2013 IEEE.
Resumo:
Background: Clinical Commissioning Groups (CCGs) are mandated to use research evidence effectively to ensure optimum use of resources by the National Health Service (NHS), both in accelerating innovation and in stopping the use of less effective practices and models of service delivery. We intend to evaluate whether access to a demand-led evidence service improves uptake and use of research evidence by NHS commissioners compared with less intensive and less targeted alternatives.
Methods/design: This is a controlled before and after study involving CCGs in the North of England. Participating CCGs will receive one of three interventions to support the use of research evidence in their decision-making:1) consulting plus responsive push of tailored evidence; 2) consulting plus an unsolicited push of non-tailored evidence; or 3) standard service unsolicited push of non-tailored evidence. Our primary outcome will be changed at 12 months from baseline of a CCGs ability to acquire, assess, adapt and apply research evidence to support decision-making. Secondary outcomes will measure individual clinical leads and managers’ intentions to use research evidence in decision making. Documentary evidence of the use of the outputs of the service will be sought. A process evaluation will evaluate the nature and success of the interactions both within the sites and between commissioners and researchers delivering the service.
Discussion: The proposed research will generate new knowledge of direct relevance and value to the NHS. The findings will help to clarify which elements of the service are of value in promoting the use of research evidence.Those involved in NHS commissioning will be able to use the results to inform how best to build the infrastructure they need to acquire, assess, adapt and apply research evidence to support decision-making and to fulfil their statutory duties under the Health and Social Care Act.
Resumo:
In the European Union, food is considered safe with regard to Listeria monocytogenes if its numbers do not exceed 100 cfu/g throughout the shelf-life of the food. Therefore, it is important to determine if a food supports growth of L. monocytogenes. Challenge tests are laboratory-based studies that measure the growth of L. monocytogenes on artificially contaminated food stored under foreseeable conditions of transportation, distribution and storage. The aim of this study was to elaborate and optimize a user-friendly protocol to perform challenge tests on food and to apply it to determine whether growth of L. monocytogenes is supported during the production and distribution of a potentially risky food i.e. mushrooms. A three-strain mixture of L. monocytogenes was inoculated onto three independent batches of whole mushrooms, sliced mushrooms, mushroom casing and mushroom substrate at a concentration of about 100 -1000 cfu/g. The batches were incubated at potential abuse temperatures, as a worst case scenario, and at intervals during storage L. monocytogenes numbers, % moisture and pH were determined. The results showed that the sliced and whole mushrooms supported growth of L. monocytogenes while mushroom casing allowed survival but did not support growth. Mushroom substrate showed a rich background microflora able of growing in Listeria selective media which hindered enumeration of L. monocytogenes. Combase predictions were not always accurate, indicating that challenge tests are a necessary part of growth determination of L. monocytogenes.
Resumo:
The rock/atmosphere interface is inhabited by a complex microbial community including bacteria, algae and fungi. These communities are prominent biodeterioration agents and remarkably influence the status of stone monuments and buildings. Deeper comprehension of natural biodeterioration processes on stone surfaces has brought about a concept of complex microbial communities referred to as "subaerial biofilms". The practical implications of biofilm formation are that control strategies must be devised both for testing the susceptibility of the organisms within the biofilm and treating the established biofilm. Model multi-species biofilms associated with mineral surfaces that are frequently refractory to conventional treatment have been used as test targets. A combination of scanning microscopy with image analysis was applied along with traditional cultivation methods and fluorescent activity stains. Such a polyphasic approach allowed a comprehensive quantitative evaluation of the biofilm status and development. Effective treatment strategies incorporating chemical and physical agents have been demonstrated to prevent biofilm growth in vitro. Model biofilm growth on inorganic support was significantly reduced by a combination of PDT and biocides
Resumo:
The future European power system will have a hierarchical structure created by layers of system control from a Supergrid via regional high-voltage transmission through to medium and low-voltage distribution. Each level will have generation sources such as large-scale offshore wind, wave, solar thermal, nuclear directly connected to this Supergrid and high levels of embedded generation, connected to the medium-voltage distribution system. It is expected that the fuel portfolio will be dominated by offshore wind in Northern Europe and PV in Southern Europe. The strategies required to manage the coordination of supply-side variability with demand-side variability will include large scale interconnection, demand side management, load aggregation and storage in the context of the Supergrid combined with the Smart Grid. The design challenge associated with this will not only include control topology, data acquisition, analysis and communications technologies, but also the selection of fuel portfolio at a macro level. This paper quantifies the amount of demand side management, storage and so-called 'back-up generation' needed to support an 80% renewable energy portfolio in Europe by 2050. © 2013 IEEE.
Resumo:
The power system of the future will have a hierarchical structure created by layers of system control from via regional high-voltage transmission through to medium and low-voltage distribution. Each level will have generation sources such as large-scale offshore wind, wave, solar thermal, nuclear directly connected to this Supergrid and high levels of embedded generation, connected to the medium-voltage distribution system. It is expected that the fuel portfolio will be dominated by offshore wind in Northern Europe and PV in Southern Europe. The strategies required to manage the coordination of supply-side variability with demand-side variability will include large scale interconnection, demand side management, load aggregation and storage in the concept of the Supergrid combined with the Smart Grid. The design challenge associated with this will not only include control topology, data acquisition, analysis and communications technologies, but also the selection of fuel portfolio at a macro level. This paper quantifies the amount of demand side management, storage and so-called ‘back-up generation’ needed to support an 80% renewable energy portfolio in Europe by 2050.
Resumo:
A dual chamber membrane reactor was used in order to study the effect of macroscopically applied oxygen chemical potential differences to a platinum catalyst supported on a mixed oxygen ion and electronic conducting membrane. It is believed that the oxygen chemical potential difference imposed by the use of an oxygen sweep in one of the reactor chambers causes the back-spillover of oxygen species from the support onto the catalyst surface, resulting in the modification of the catalytic activity. The use of different sweep gases, such as ethylene and hydrogen was investigated as the means to reverse the rate modification by removing the spilt over species from the catalyst surface and returning the system to its initial state. Oxygen sweep in general had a positive effect on the reaction rate with rate increases up to 20% measured. Experimental results showed that hydrogen is a more potent sweep gas than ethylene in terms of the ability to reverse rate modification. A 10% rate loss was observed when using an ethylene sweep as compared with an almost 60% rate decrease when hydrogen was used as the sweep gas. © 2009 Elsevier Ltd. All rights reserved.
Resumo:
A novel configuration for the in situ control of the catalytic activity of a polycrystalline Pt catalyst supported on a mixed ionic electronic conducting (MIEC) substrate is investigated. The modification of the catalytic activity is achieved by inducing the reverse spillover of oxygen promoting species from the support onto the catalyst surface, thus modifying the chemisorptive bond energy of the gas phase adsorbed reactants. This phenomenon is known as Electrochemical Promotion of Catalysis (EPOC). In this work we investigate the use of a wireless system that takes advantage of the mixed ionic electronic conductivity of the catalyst support (internally short-circuiting the system) in a dual chamber reactor. In this wireless configuration, the reaction takes place in one chamber of the membrane reactor while introduction of the promoting species is achieved by the use of an appropriate sweep gas (and therefore control of the oxygen chemical potential difference across the membrane) on the other chamber. Experimental results have shown that the catalytic rate can be enhanced by using an oxygen sweep, while a hydrogen sweep can reverse the changes. Total rate enhancement ratios of up to 3.5 were measured. © 2008 Elsevier B.V. All rights reserved.
Resumo:
Importance: The natural history of patients with newly diagnosed high-risk nonmetastatic (M0) prostate cancer receiving hormone therapy (HT) either alone or with standard-of-care radiotherapy (RT) is not well documented. Furthermore, no clinical trial has assessed the role of RT in patients with node-positive (N+) M0 disease. The STAMPEDE Trial includes such individuals, allowing an exploratory multivariate analysis of the impact of radical RT.
Objective: To describe survival and the impact on failure-free survival of RT by nodal involvement in these patients.
Design, Setting, and Participants: Cohort study using data collected for patients allocated to the control arm (standard-of-care only) of the STAMPEDE Trial between October 5, 2005, and May 1, 2014. Outcomes are presented as hazard ratios (HRs) with 95% CIs derived from adjusted Cox models; survival estimates are reported at 2 and 5 years. Participants were high-risk, hormone-naive patients with newly diagnosed M0 prostate cancer starting long-term HT for the first time. Radiotherapy is encouraged in this group, but mandated for patients with node-negative (N0) M0 disease only since November 2011.
Exposures: Long-term HT either alone or with RT, as per local standard. Planned RT use was recorded at entry.
Main Outcomes and Measures: Failure-free survival (FFS) and overall survival.
Results: A total of 721 men with newly diagnosed M0 disease were included: median age at entry, 66 (interquartile range [IQR], 61-72) years, median (IQR) prostate-specific antigen level of 43 (18-88) ng/mL. There were 40 deaths (31 owing to prostate cancer) with 17 months' median follow-up. Two-year survival was 96% (95% CI, 93%-97%) and 2-year FFS, 77% (95% CI, 73%-81%). Median (IQR) FFS was 63 (26 to not reached) months. Time to FFS was worse in patients with N+ disease (HR, 2.02 [95% CI, 1.46-2.81]) than in those with N0 disease. Failure-free survival outcomes favored planned use of RT for patients with both N0M0 (HR, 0.33 [95% CI, 0.18-0.61]) and N+M0 disease (HR, 0.48 [95% CI, 0.29-0.79]).
Conclusions and Relevance: Survival for men entering the cohort with high-risk M0 disease was higher than anticipated at study inception. These nonrandomized data were consistent with previous trials that support routine use of RT with HT in patients with N0M0 disease. Additionally, the data suggest that the benefits of RT extend to men with N+M0 disease.
Trial Registration: clinicaltrials.gov Identifier: NCT00268476; ISRCTN78818544.
Resumo:
This paper describes a smart grid test bed comprising embedded generation, phasor measurement units (PMUs), and supporting ICT components and infrastructure. The test bed enables the development of a use case focused on a synchronous islanding scenario, where the embedded generation becomes islanded from the mains supply. Due to the provisioned control components, control strategy, and best-practice ICT support infrastructure, the islanded portion of the grid is able to continue to operate in a secure and dependable manner.