49 resultados para corneal topography


Relevância:

20.00% 20.00%

Publicador:

Resumo:

PURPOSE: To assess the correlation between central corneal thickness (CCT) and anterior scleral thickness (ST) in patients of primary open-angle glaucoma (POAG), normal tension glaucoma (NTG), and ocular hypertension (OHT). PATIENTS AND METHODS: Consecutive patients with OHT, POAG, NTG, and normal individuals were recruited. CCT was measured by ultrasonic pachymetry, whereas ST was measured using ultrasonic biomicroscopy at the temporal quadrant, 2'mm posterior to the scleral spur. Investigators were masked to the diagnosis and CCT/ ultrasonic biomicroscopy data. Correlation between mean CCT and ST was analyzed. RESULTS: One hundred and twenty-four subjects (31 with OHT, 31 with POAG, 31 with NTG, and 31 normal individuals) were enrolled. The CCT (OHT 548.06±30.45'µm; POAG 519.39±42.95'µm; NTG 505.81±27.23'µm; controls 529.90±43.40'µm) was found to be thicker in patients with OHT than POAG (P=0.004) or NTG (P

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The degree of gene hypermethylation in non-neoplastic colonic mucosa (NNCM) is a potentially important event in the development of colorectal cancer (CRC), particularly for the subgroup with a CpG island methylator phenotype (CIMP). In this study, we aimed to use an unbiased and high-throughput approach to evaluate the topography of DNA methylation in the non-neoplastic colonic mucosa (NNCM) surrounding colorectal cancer (CRC). A total of 61 tissue samples comprising 53 NNCM and 8 tumor samples were obtained from hemicolectomy specimens of two CRC patients (Cases 1 and 2). NNCM was stripped from the underlying colonic wall and samples taken at varying distances from the tumor. The level of DNA methylation in NNCM and tumor tissues was assessed at 1,505 CpG sites in 807 cancer-related genes using Illumina GoldenGate® methylation arrays. Case 1 tumor showed significantly higher levels of methylation compared to surrounding NNCM samples (P?

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Mutations in ZEB1 have been reported in posterior polymorphous corneal dystrophy (PPCD3; MIM #609141) and Fuchs' endothelial corneal dystrophy (FECD6; MIM #613270). Although PPCD and keratoconus are clinically and pathologically distinct, PPCD has been associated with keratoconus, suggesting a common genetic basis. The purpose of our study was to perform mutational screening of the ZEB1 gene in patients affected with keratoconus or PPCD.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Objective: To investigate the effect of socioeconomic deprivation on cornea graft survival in the United Kingdom.

Design: Retrospective cohort study.

Participants: All the recipients (n = 13?644) undergoing their first penetrating keratoplasty (PK) registered on the United Kingdom Transplant Registry between April 1999 and March 2011 were included.

Methods: Data of patients' demographic details, indications, graft size, corneal vascularization, surgical complication, rejection episodes, and postoperative medication were collected at the time of surgery and 1, 2, and 5 years postoperatively. Patients with endophthalmitis were excluded from the study. Patients' home postcodes were used to determine the socioeconomic status using a well-validated deprivation index in the United Kingdom: A Classification of Residential Neighborhoods (ACORN). Kaplan–Meier survival and Cox proportional hazards regression were used to evaluate the influence of ACORN categories on 5-year graft survival, and the Bonferroni method was used to adjust for multiple comparisons.

Main Outcome Measures: Patients' socioeconomic deprivation status and corneal graft failure.

Results: A total of 13?644 patients received their first PK during the study periods. A total of 1685 patients (13.36%) were lost to follow-up, leaving 11?821 patients (86.64%) for analysis. A total of 138 of the 11?821 patients (1.17%) developed endophthalmitis. The risk of graft failure within 5 years for the patients classified as hard-pressed was 1.3 times that of the least deprived (hazard ratio, 1.3; 95% confidence interval, 1.1–1.5; P = 0.003) after adjusting for confounding factors and indications. There were no statistically significant differences between the causes of graft failure and the level of deprivation (P = 0.14).

Conclusions: Patients classified as hard-pressed had an increased risk of graft failure within 5 years compared with the least deprived patients.

Financial Disclosure(s): The author(s) have no proprietary or commercial interest in any materials discussed in this article

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Corneal endothelial cells from normal and traumatized human, primate, cat and rabbit eyes were studied by specular microscopy. Morphometric analysis was performed on micrographs of corneal endothelium using a semi-automated image analysis system. The results showed that under normal conditions the corneal endothelium of all four species exhibit major morphological similarities (mean cell areas: human 317 +/- 32 microns 2, primate 246 +/- 22 microns2, cat 357 +/- 25 microns 2, rabbit 308 +/- 35 microns 2). The normal corneal endothelium in man was found to be more polymegethous than that of the other species. Trauma to cat, primate and human corneas resulted in a long-term reduction in endothelial cell density and enhanced polymegethism. In contrast, the reparative response of the rabbit ensured the reformation of an essentially normal monolayer following injury. Endothelial giant cells were a normal inclusion in the rabbit corneal endothelium but were only significant in cat, primate and man following trauma. The presence of corneal endothelial giant cells in amitotic corneas may therefore represent a compensatory response in the absence of mitotic potential.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Purpose: To assess the demographics and distribution of corneal astigmatism before cataract surgery in Chinese patients. Setting: State Key Laboratory of Ophthalmology, Zhongshan Ophthalmic Center, Sun Yat-sen University, Guangzhou, China. Design: Clinic-based cross-sectional study. Methods: From July 2009 to May 2011, preoperative bilateral partial coherence interferometry (IOLMaster) was performed in consecutive patients having cataract surgery. Patient demographics and keratometric data were recorded. Results: The mean age of the 2849 patients (4831 eyes) was 70.56 years ± 9.55 (SD); there was a predominance of women patients (64.0%). The mean axial length was 23.58 ± 1.13 mm. The mean corneal astigmatism in this cohort was 1.01 D (range 0.05 to 6.59 D). Corneal astigmatism was between 0.25 D and 1.25 D in 67.7% of eyes, 1.25 D or higher in 27.5% eyes, and less than 0.25 D in 4.8% of eyes. Astigmatism was with the rule in 25.1% of eyes, against the rule (ATR) in 58.2% of eyes, and oblique in 16.7% of eyes. The mean steep keratometry measurement was 44.76 ± 1.56 D. Against-the-rule astigmatism increased significantly with older age. Conclusions: Corneal astigmatism largely fell between 0.25 D and 1.25 D in these predominantly elderly female Chinese patients, and ATR astigmatism increased with age. Financial Disclosure: No author has a financial or proprietary interest in any material or method mentioned. © 2012 ASCRS and ESCRS.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

PURPOSE:

To explore the potential association between adverse corneal events and the use of topical nonsteroidal antiinflammatory drugs (NSAIDs).

SETTING:

Practice-based reports.

METHODS:

A detailed case-reporting form and request for medical records were sent to all practices reporting cases of corneal or conjunctival pathology in association with the use of topical NSAIDs to the American Society of Cataract and Refractive Surgery. Cases were classified as "mild," "moderate," or "severe" according to predetermined clinical criteria.

RESULTS:

Records of 140 eyes (129 patients) were reviewed; 51 cases (36.4%) were mild, 55 (39.3%) moderate, and 34 (24.3%) severe. An association with a specific topical NSAID was confirmed in 117 cases (81.8%). Most confirmed cases (53.8%) involved generic diclofenac (Falcon). Cases associated with brand diclofenac (Voltaren, CIBA Vision) and ketorolac (Acular, Allergan) were more likely to have ocular comorbidity and to have received significantly higher total doses of NSAIDs. Neither "off-label" use nor use of any specific agent was associated with severe compared to mild or moderate disease. However, patients with more severe adverse events were more likely to have a history of diabetes, previous surgery in the affected eye, and surgery other than cataract. Cases not occurring in the perioperative period had significantly worse outcomes, had significantly more ocular comorbidities, and received nearly 3 times the dose of NSAIDs.

CONCLUSIONS:

While topical NSAIDs as a class may be associated with severe adverse events, such events appeared to require potentiation in the form of high total doses, ocular comorbidities, or both with Acular and Voltaren. Severe adverse events might have been more likely to occur at lower doses and in routine postoperative settings with generic diclofenac.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

PURPOSE:

We sought to measure the impact of central corneal thickness (CCT), a possible risk factor for glaucoma damage, and corneal hysteresis, a proposed measure of corneal resistance to deformation, on various indicators of glaucoma damage.

DESIGN:

Observational study.

METHODS:

Adult patients of the Wilmer Glaucoma Service underwent measurement of hysteresis on the Reichert Ocular Response Analyzer and measurement of CCT by ultrasonic pachymetry. Two glaucoma specialists (H.A.Q., N.G.C.) reviewed the chart to determine highest known intraocular pressure (IOP), target IOP, diagnosis, years with glaucoma, cup-to-disk ratio (CDR), mean defect (MD), pattern standard deviation (PSD), glaucoma hemifield test (GHT), and presence or absence of visual field progression.

RESULTS:

Among 230 subjects, the mean age was 65 +/- 14 years, 127 (55%) were female, 161 (70%) were white, and 194 (85%) had a diagnosis of primary open-angle glaucoma (POAG) or suspected POAG. In multivariate generalized estimating equation models, lower corneal hysteresis value (P = .03), but not CCT, was associated with visual field progression. When axial length was included in the model, hysteresis was not a significant risk factor (P = .09). A thinner CCT (P = .02), but not hysteresis, was associated with a higher CDR at the most recent examination. Neither CCT nor hysteresis was associated with MD, PSD, or GHT "outside normal limits."

CONCLUSIONS:

Thinner CCT was associated with the state of glaucoma damage as indicated by CDR. Axial length and corneal hysteresis were associated with progressive field worsening.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

PURPOSE OF REVIEW:

Highlights recent studies relating to the impact of corneal structure and biomechanical properties on glaucoma evaluation and management.

RECENT FINDINGS:

Central corneal thickness has been shown to play a role in the interpretation of intraocular pressure. Central corneal thickness has also been suggested as a glaucoma risk factor. The potential role of other corneal factors, such as stromal makeup, in the accurate measurement of intraocular pressure and the assessment of glaucoma risk remains to be determined.

SUMMARY:

Improved understanding of central corneal thickness and corneal biomechanical properties may someday lead to a better understanding of glaucoma risk and its assessment.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

PURPOSE: To estimate the relationships between ocular parameters and tonometrically measured intraocular pressure (IOP), to determine the influence of ocular parameters on different instrument measurements of IOP, and to evaluate the association of ocular parameters with a parameter called hysteresis. METHODS: Patients presenting at a glaucoma clinic were recruited for this study. Subjects underwent IOP measurement with the Goldmann applanation tonometer (GAT), the TonoPen, and the Reichert Ocular Response Analyzer (ORA), and also measurements of central corneal thickness (CCT), axial length, corneal curvature, corneal astigmatism, central visual acuity, and refractive error. Chart information was reviewed to determine glaucoma treatment history. The ORA instrument provided a measurement called corneal hysteresis. The association between measured IOP and the other ocular characteristics was estimated using generalized estimating equations. RESULTS: Among 230 patients, IOP measurements from the TonoPen read lowest, and ORA read highest, and GAT measurements were closest to the mean IOP of the 3 instruments. In a multiple regression model adjusting for age, sex, race, and other ocular characteristics, a 10 microm increase in CCT was associated with an increase of 0.79 mm Hg measured IOP in untreated eyes (P<0.0001). Of the 3 tonometers, GAT was the least affected by CCT (0.66 mm Hg/10 mum, P<0.0001). Hysteresis was significantly correlated with CCT with a modest correlation coefficient (r=0.20, P<0.0007). CONCLUSIONS: Among parameters related to measured IOP, features in addition to CCT, such as hysteresis and corneal curvature, may also be important. Tonometric instruments seem to be affected differently by various physiologic characteristics.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

PURPOSE: To evaluate the association between corneal hysteresis and axial length/refractive error among rural Chinese secondary school children. DESIGN: Cross-sectional cohort study. METHODS: Refractive error (cycloplegic auto-refraction with subjective refinement), central corneal thickness (CCT) and axial length (ultrasonic measurement), intraocular pressure (IOP), and corneal hysteresis (Reichert Ocular Response Analyzer) were measured on a rural school-based cohort of children. RESULTS: Among 1,233 examined children, the mean age was 14.7 +/- 0.8 years and 699 (56.7%) were girls. The mean spherical equivalent (n = 1,232) was -2.2 +/- 1.6 diopters (D), axial length (n = 643) was 23.7 +/- 1.1 mm, corneal hysteresis (n = 1,153) was 10.7 +/- 1.6 mm Hg, IOP (n = 1,153) was 17.0 +/- 3.4 mm Hg, and CCT (n = 1,226) was 553 +/- 33 microns. In linear regression models, longer axial length was significantly (P < .001 for both) associated with lower corneal hysteresis and higher IOP. Hysteresis in this population was significantly (P < .001) lower than has previously been reported for normal White children (n = 42, 12.3 +/- 1.3 mm Hg), when adjusting for age and gender. This difference did not appear to depend on differences in axial length between the populations, as it persists when only Chinese children with normal uncorrected vision are included. CONCLUSIONS: Prospective studies will be needed to determine if low hysteresis places eyes at risk for axial elongation secondary or if primary elongation results in lower hysteresis.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

PURPOSE: Low corneal hysteresis is associated with longer axial length in Chinese secondary school children. The authors sought to explore this association in primary school children. METHODS: LogMAR presenting visual acuity, cycloplegic refractive error, ocular biometry, central corneal thickness (CCT), and corneal hysteresis (CH) was assessed for children in grades 1 to 3 at an academically competitive urban school in Shantou, China. RESULTS: Among 872 eligible children (mean age, 8.6 ± 2.1 years), 651 (74.7%) completed the examination. Among 1299 examined eyes, 111 (8.5%) had uncorrected vision ≤6/12. Mean spherical equivalent refractive error for all eyes was +0.26 ± 1.41 D, and axial length (AL) was 22.7 ± 0.90 mm. CH for the lowest (mean AL, 21.7 ± 0.39 mm), two middle (mean AL, 22.4 ± 0.15 and 22.9 ± 0.15 mm), and highest quartiles (mean AL, 23.7 ± 0.74 mm) of AL were 10.6 ± 2.1 mm Hg, 10.4 ± 2.1 mm Hg, 10.3 ± 2.3 mm Hg, and 10.2 ± 2.3 mm Hg respectively (age- and gender-adjusted Pearson's correlation coefficient r = -0.052; P = 0.001). In generalized estimating equation models adjusting for age, gender, and CCT, lower CH was significantly associated with longer AL (P < 0.001) and more myopic refractive error (P = 0.001). CONCLUSIONS: CH measurement is practical in young children because this is when myopia undergoes its most rapid progression. Prospective follow-up of this cohort at high risk for myopia is under way to determine whether low CH is predictive, or a consequence, of long AL.