168 resultados para breeding line


Relevância:

20.00% 20.00%

Publicador:

Resumo:

We describe medium-resolution spectroscopic observations taken with the ESO Multi-Mode Instrument (EMMI) in the CaII K line (lambda air = 3933.661 angstrom) towards 7 QSOs located in the line-of-sight to the Magellanic Bridge. At a spectral resolution R =lambda/Delta lambda = 6000, five of the sightlines have a signal-to-noise ( S/N) ratio of similar to 20 or higher. Definite Ca absorption due to Bridge material is detected towards 3 objects, with probable detection towards two other sightlines. Gas-phase CaII K Bridge and Milky Way abundances or lower limits for the all sightlines are estimated by the use of Parkes 21-cm H. emission line data. These data only have a spatial resolution of 14 arcmin compared with the optical observations which have milli-arcsecond resolution. With this caveat, for the three objects with sound CaII K detections, we find that the ionic abundance of CaII K relative to HI, A = log( N( CaK)/ N( HI)) for low- velocity Galactic gas ranges from - 8.3 to - 8.8 dex, with HI column densities varying from 3- 6 x 10(20) cm(-2). For Magellanic Bridge gas, the values of A are similar to 0.5 dex higher, ranging from similar to- 7.8 to - 8.2 dex, with N( HI) = 1- 5 x 1020 cm(-2). Higher values of A correspond to lower values of N( HI), although numbers are small. For the sightline towards B 0251 - 675, the Bridge gas has two different velocities, and in only one of these is CaII tentatively detected, perhaps indicating gas of a different origin or present-day characteristics ( such as dust content), although this conclusion is uncertain and there is the possibility that one of the components could be related to the Magellanic Stream. Higher signal-to-noise CaII K data and higher resolution H. data are required to determine whether A changes with N( HI) over the Bridge and if the implied difference in the metalicity of the two Bridge components towards B 0251-675 is real.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Photon yields for the 1s(2)-1s2p (He-alpha) transition of He- like ions have been measured for laser irradiated, thin foils of Ti, V and Fe. The laser pulses were of 0.527 mum wavelength and of either 80 or 300 ps duration. The data shows significant shot-to-shot variation but the Ti data is broadly consistent with previous results. In this work, we extend the previous results to include, new elements, longer pulse lengths and yields measured for emission from both surfaces of the foils. We compare our data to simulations using a hydrodynamic code and a collisional radiative model.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

We report on our findings of the bright, pulsating, helium atmosphere white dwarf GD 358, based on time-resolved optical spectrophotometry. We identify 5 real pulsation modes and at least 6 combination modes at frequencies consistent with those found in previous observations. The measured Doppler shifts from our spectra show variations with amplitudes of up to 5.5 km s-1 at the frequencies inferred from the flux variations. We conclude that these are variations in the line-of-sight velocities associated with the pulsational motion. We use the observed flux and velocity amplitudes and phases to test theoretical predictions within the convective driving framework, and compare these with similar observations of the hydrogen atmosphere white dwarf pulsators (DAVs). The wavelength dependence of the fractional pulsation amplitudes (chromatic amplitudes) allows us to conclude that all five real modes share the same spherical degree, most likely, l=1. This is consistent with previous identifications based solely on photometry. We find that a high signal-to-noise mean spectrum on its own is not enough to determine the atmospheric parameters and that there are small but significant discrepancies between the observations and model atmospheres. The source of these remains to be identified. While we infer Teff =24 kK and log g ~ 8.0 from the mean spectrum, the chromatic amplitudes, which are a measure of the derivative of the flux with respect to the temperature, unambiguously favour a higher effective temperature, 27 kK, which is more in line with independent determinations from ultra-violet spectra.