159 resultados para Technical loss


Relevância:

20.00% 20.00%

Publicador:

Resumo:

This paper presents a new method for complex power flow tracing that can be used for allocating the transmission loss to loads or generators. Two algorithms for upstream tracing (UST) and downstream tracing (DST) of the complex power are introduced. UST algorithm traces the complex power extracted by loads back to source nodes and assigns a fraction of the complex power flow through each line to each load. DST algorithm traces the output of the generators down to the sink nodes determining the contributions of each generator to the complex power flow and losses through each line. While doing so, active- and reactive-power flows as well as complex losses are considered simultaneously, not separately as most of the available methods do. Transmission losses are taken into consideration during power flow tracing. Unbundling line losses are carried out using an equation, which has a physical basis, and considers the coupling between active- and reactive-power flows as well as the cross effects of active and reactive powers on active and reactive losses. The tracing algorithms introduced can be considered direct to a good extent, as there is no need for exhaustive search to determine the flow paths as these are determined in a systematic way during the course of tracing. Results of application of the proposed method are also presented.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

This paper presents a new method for transmission loss allocation. The method is based on tracing the complex power flow through the network and determining the share of each load on the flow and losses through each line. Transmission losses are taken into consideration during power flow tracing. Unbundling line losses is carried out using an equation, which has a physical basis, and considers the coupling between active and reactive power flows as well as the cross effects of active and reactive power on active and reactive losses. A tracing algorithm which can be considered direct to a good extent, as there is no need for exhaustive search to determine the flow paths as these are determined in a systematic way during the course of tracing. Results of application of the proposed method are also presented.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

This paper presents a new method for transmission loss allocation in a deregulated electrical power market. The proposed method is based on physical flow through transmission lines. The contributions of individual loads to the line flows are used as basis for allocating transmission losses to different loads. With minimum assumptions, that sound to be reasonable and cannot be rejected, a novel loss allocation formula is derived. The assumptions made are: a number of currents sharing a transmission line distribute themselves over the cross section in the same manner; that distribution causes the minimum possible power loss. Application of the proposed method is straightforward. It requires only a solved power flow and any simple algorithm for power flow tracing. Both active and reactive powers are considered in the loss allocation procedure. Results of application show the accuracy of the proposed method compared with the commonly used procedures.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

175 nm-thick Ba0.5Sr0.5TiO3 (BST) thin film fabricated by pulsed laser deposition (PLD) technique is found to be a mixture of two distributions of material. We discuss whether these two components are nano-regions of paraelectric and ferroelectric phases, or a bimodal grain-size distribution, or an effect of oxygen vacancy gradient from the electrode interface. The fraction of switchable ferroelectric phase decreases under bipolar pulsed fields, but it recovers after removal of the external fields. The plot of capacitance in decreasing dc voltage (C(Vdown arrow) versus that in increasing dc 61 voltage C(Vup arrow) is a superposition of overlapping of two triangles, in contrast to one well-defined triangle for typical ferroelectric SrBi2Ta2O9 thin films.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The performance of a very low loss frequency selective surface (FSS) comprising two air spaced planar arrays of linear slot elements is reported. The beamsplitter generates a low loss passband response with a very sharp transmission roll-off with frequency. Simulated and measured results in the 30 GHz and 300 GHz wavebands are used to quantify the performance improvement compared to a conventional multilayer dielectrically backed conducting ring FSS. The paper also discusses the effect of the array dimensions on the passband width and filter roll-off rate.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The role of limpet grazing in preventing the development of algal canopies is a recurrent theme in intertidal ecology. Less is known about interactions of limpets with the long-term dynamics of established canopies. Aerial photographs indicate that intertidal canopy cover has declined over the past 44 yr in Strangford Lough, Northern Ireland. There has been a loss of the previously continuous cover of Ascophyllum nodosum (L.) Le Jolis in the mid-shore. A barnacles dominated assemblage now fills gaps in the A. nodosum canopy. The rates at which barnacle patches become established and grow have increased since 1990. Changes in canopy cover have been accompanied by increases in limpet densities since the 1980s. Measurements between 2003 and 2004 showed no increase in length of A. nodosum fronds when limpets Patella vulgata had access to the algal holdfasts. In contrast, when limpets were experimentally excluded from the holdfasts, there was net frond growth. In the Isle of Man, which is climatically similar to Strangford Lough but has fewer limpets, growth occurred regardless of limpet grazing. The breaking force for A. nodosum declined with increasing local densities of limpets. A. nodosum is a sheltered shore species, potentially vulnerable to changes in wave exposure. There is no evidence, however, that Strangford Lough has become windier over the past 3 decades. Variation in wave exposure among locations within the lough was not related to rates of barnacle patch creation or expansion, Limpet population density has increased following a series of mild winters. Climate change may have a role in causing canopy loss, not by direct effects on the limpet populations.