37 resultados para Small-angle neutron scattering (SANS)


Relevância:

40.00% 40.00%

Publicador:

Resumo:

A novel wide angle spectrometer has been implemented with a highly oriented pyrolytic graphite crystal coupled to an image plate. This spectrometer has allowed us to look at the energy resolved spectrum of scattered x rays from a dense plasma over a wide range of angles ( ~ 30°) in a single shot. Using this spectrometer we were able to observe the temporal evolution of the angular scatter cross section from a laser shocked foil. A spectrometer of this type may also be useful in investigations of x-ray line transfer from laser-plasmas experiments.

Relevância:

40.00% 40.00%

Publicador:

Resumo:

Synchronisation of small distributed generation, 30 kVA–2 MVA, employing salient-pole synchronous machines is normally performed within a narrow range of tolerances for voltage, frequency and phase angle. However, there are situations when the ability to synchronise with non-ideal conditions would be beneficial. Such applications include power system islanding and rapid generator start-up. The physical process and effect of out-of-phase synchronisation is investigated both through simulation and experimental tests on a salient-pole alternator. There are many factors that affect synchronisation, but particular attention is given to synchronisation angle, voltage difference and, as generators will be loaded during islanding, the load angle. The results suggest that it would be acceptable for the maximum synchronisation angle of distributed generation to exceed that of current practice. Interesting observations on the nature of out-of-phase synchronisation are made, including some specific to small salient-pole synchronous machines. Furthermore, recommendations are made for synchronisation under different system conditions.

Relevância:

40.00% 40.00%

Publicador:

Resumo:

Purpose: A peripheral iridotomy (PI) is the treatment of choice for pupillary block. In this study we investigated the effect of enlarging the size of a small PI on the anterior chamber angle in patients with angle closure using ultrasound biomicroscopy (UBM). Patients and Methods: Patients who had been treated with laser peripheral iridotomy for angle closure and were identified to have a small patent PI (<100 µm) with still appositionally closed anterior chamber angle were selected prospectively. The anterior chamber angle was assessed using UBM. The angle opening distance 500 µm from the scleral spur (AOD500) as well as the anterior and posterior chamber depth (ACD and PCD) 1000 µm from the scleral spur was measured. In addition, the ACD/PCD ratio was calculated. Afterwards, the PI was enlarged using an Nd: YAG laser and the UBM measurements were repeated as described above. Results: Six eyes of six patients were examined. After the enlargement of the PI the average AOD500 increased from 109 µm (±36) to 147 µm (±40) (p