40 resultados para Sensor Data Fusion Applicazioni
Resumo:
This chapter presents a novel hand-held instrument capable of real-time in situ detection and identification of heavy metals, along with the potential use of novel taggants in environmental forensic investigations. The proposed system provides the facilities found in a traditional laboratory-based instrument but in a hand held design, without the need for an associated computer. The electrochemical instrument uses anodic stripping voltammetry, which is a precise and sensitive analytical method with excellent limits of detection. The sensors comprise a small disposable plastic strip of screen-printed electrodes rather than the more common glassy carbon disc and gold electrodes. The system is designed for use by a surveyor on site, allowing them to locate hotspots, thus avoiding the expense and time delay of prior laboratory analysis. This is particularly important in environmental forensic analysis when a site may have been released back to the owner and samples could be compromised on return visits. The system can be used in a variety of situations in environmental assessments, the data acquired from which provide a metals fingerprint suitable for input to a database. The proposed novel taggant tracers, based on narrow-band atomic fluorescence, are under development for potential deployment as forensic environmental tracers. The use of discrete fluorescent species in an environmentally stable host has been investigated to replace existing toxic, broadband molecular dye tracers. The narrow band emission signals offer the potential for tracing a large number of signals in the same environment. This will give increased data accuracy and allow multiple source environmental monitoring of environmental parameters.
Resumo:
As part of any drilling cuttings pile removal process the requirement for monitoring the release of contaminants into the marine environment will be critical. Traditional methods for such monitoring involve taking samples for laboratory analysis. This process is time consuming and only provides data on spot samples taken from a limited number of locations and time frames. Such processes, therefore, offer very restricted information. The need for improved marine sensors for monitoring contaminants is established. We report here the development and application of a multi-capability optical sensor for the real-time in situ monitoring of three key marine environmental and offshore/oil parameters: hydrocarbons, synthetic-based fluids and heavy metal concentrations. The use of these sensors will be a useful tool for real-time in situ environmental monitoring during the process of decommissioning offshore structures. Multi-capability array sensors could also provide information on the dispersion of contamination from drill cuttings piles either while they are in situ or during their removal.
Resumo:
For the reliable analysis and modeling of astrophysical, laser-produced, and fusion plasmas, atomic data are required for a number of parameters, including energy levels, radiative rates, and electron impact excitation rates. Such data are desired for a range of elements (H to W) and their many ions. However, measurements of atomic data, mainly for radiative and excitation rates, are not feasible for many species, and therefore, calculations are needed. For some ions (such as of C, Fe, and Kr), there is a variety of calculations available in the literature, but often, they differ significantly from one another. Therefore, there is a great demand from the user community to have data "assessed" for accuracy so that they can be confidently applied to the modeling of plasmas. In this paper we highlight the difficulties in assessing atomic data and offer some solutions for improving the accuracy of calculated results.
Resumo:
This paper presents a novel method of audio-visual fusion for person identification where both the speech and facial modalities may be corrupted, and there is a lack of prior knowledge about the corruption. Furthermore, we assume there is a limited amount of training data for each modality (e.g., a short training speech segment and a single training facial image for each person). A new representation and a modified cosine similarity are introduced for combining and comparing bimodal features with limited training data as well as vastly differing data rates and feature sizes. Optimal feature selection and multicondition training are used to reduce the mismatch between training and testing, thereby making the system robust to unknown bimodal corruption. Experiments have been carried out on a bimodal data set created from the SPIDRE and AR databases with variable noise corruption of speech and occlusion in the face images. The new method has demonstrated improved recognition accuracy.
Resumo:
Performance data for a dye based, regenerable oxygen sensor (Mills and Lawrie [1], Mills et al. [2]) are analyzed to develop useful kinetic models for sensor photoactivation (dye reduction) and dark, oxygen detection (dye oxidation). The titania loaded, thin film sensor exhibits an apparent first order photoactivation of the dye, which we demonstrate (Section 3.2 and Fig. 4) is due to a kinetic disguise of a zero order photoreaction occurring through a non-uniformly illuminated sensor film. The observed zero order, slow recovery due to dye oxidation by dioxygen (O2 detection) appears best rationalized by a model assuming a near O2-impermeable skin developing on the sensor surface as solvent is evaporatively removed following sensor film casting and curing.
Resumo:
Tungsten will be employed as a plasma facing material in the ITER fusion reactor under construction in Cadarache, France; therefore, there is a significant need for accurate electron-impact excitation and ionization data for the ions of tungsten. We report on the results of extensive calculations of ionization and excitation for W 3+ that are intended to provide the atomic data needed for the determination of impurity influx diagnostics of tungsten in several existing tokamak reactors. The electron-impact excitation rate coefficients for this study were determined using the relativistic R -matrix method. The contribution to direct electron-impact ionization was determined using the distorted-wave approximation, the accuracy of which was verified by an R -matrix with pseudo states calculation. Contributions to total ionization from excitation autoionization were also generated from the relativistic R -matrix method. These results were then employed to calculate values of ionization per emitted photon, or SXB ratios, for four carefully selected spectral lines; these data will allow the determination of impurity influx from tungsten facing surfaces. For the range of densities of importance in the edge region of a tokamak reactor, these SXB ratios are found to be nearly independent of electron density but vary significantly with electron temperature.
Resumo:
With the focus of ITER on the transport and emission properties of tungsten, generating atomic data for complex species has received much interest. Focusing on impurity influx diagnostics, we discuss recent work on heavy species. Perturbative approaches do not work well for near neutral systems so non-perturbative data are required, presenting a particular challenge for these influx diagnostics. Recent results on Mo+ are given as an illustration of how the diagnostic applications can guide the theoretical calculations for such systems.
Resumo:
Electron-impact excitation collision strengths for transitions between all singly excited levels up to the n = 4 shell of helium-Eke argon and the n = 4 and 5 shells of helium-like iron have been calculated using a radiation-damped R-matrix approach. The theoretical collision strengths have been examined and associated with their infinite-energy limit values to allow the preparation of Maxwell-averaged effective collision strengths. These are conservatively considered to be accurate to within 20% at all temperatures, 3 x 10(5)-3 x 10(8) K forAr(16+) and 10(6)-10(9) K for Fe24+. They have been compared with the results of previous studies, where possible, and we find a broad accord. The corresponding rate coefficients are required for use in the calculation of derived, collisional-radiative, effective emission coefficients for helium-like lines for diagnostic application to fusion and astrophysical plasmas. The uncertainties in the fundamental collision data have been used to provide a critical assessment of the expected resultant uncertainties in such derived data, including redistributive and cascade collisional-radiative effects. The consequential uncertainties in the parts of the effective emission coefficients driven by excitation from the ground levels for the key w, x, y and z lines vary between 5% and 10%. Our results remove an uncertainty in the reaction rates of a key class of atomic processes governing the spectral emission of helium-like ions in plasmas.
Resumo:
A first-stage collision database is assembled which contains electron-impact excitation, ionization, and recombination rate coefficients for Be, Be+, Be2+, and Be3+. The first-stage database is constructed using the R-matrix with pseudo-states, time-dependent close-coupling, and perturbative, distorted-wave methods. A second-stage collision database is then assembled which contains generalized collisional-radiative and radiated power loss coefficients. The second-stage database is constructed by solution of collisional-radiative equations in the quasi-static equilibrium approximation using the first-stage database. Both collision database stages reside in electronic form at the ORNL Controlled Fusion Atomic Data Center and in the ADAS database, and are easily accessed over the worldwide internet. © 2007 Elsevier Inc. All rights reserved.
Resumo:
A first stage collision database is assembled which contains electron-impact effective collision strengths, and ionization and recombination rate coefficients for Li, Li+, and Li2+. The first stage database is constructed using the R-matrix with pseudo-states, time-dependent close-coupling, converged close-coupling, and perturbative distorted-wave methods. A second stage collision database is then assembled which contains generalized collisional-radiative and radiated power loss coefficients. The second stage database is constructed by solution of collisional-radiative equations in the quasi-static equilibrium approximation using the first stage database. Both collision database stages reside in electronic form at the ORNL Controlled Fusion Atomic Data Center and in the ADAS database, and are easily accessed over the worldwide internet. ?? 2006 Elsevier Inc. All rights reserved.