154 resultados para Satisfaction conjugale--Tests


Relevância:

20.00% 20.00%

Publicador:

Resumo:

Objectives: Recent advances in mental health care policy and service delivery have lead to the development of community care initiatives which have enabled those individuals traditionally cared for in hospital environments to be resettled successfully in community living arrangements that foster an ethos of empowerment and recovery. This study sought to identify differences between a hospital continuing care group (n = 16) and a community placement group (n = 20) in relation to quality of life, satisfaction and levels of empowerment. Method: The study was a cross-sectional design. It follows up a cohort of individuals identified as the ‘hospital continuing care group’ (365+ consecutive days in psychiatric hospital care) by Homefirst Community Trust in Northern Ireland. A proportion of this population has been resettled into community care environments and some continue to reside in hospital. Patients both in the hospital continuing care group and the community placement group completed two standard questionnaires that covered a number of variables including empowerment, quality of life and service satisfaction. Results: There were significant differences between the hospital continuing care and community placement groups across scores on service satisfaction, quality of life, and empowerment in the current study. Hypotheses relating to service satisfaction (z = -4.117; p

Relevância:

20.00% 20.00%

Publicador:

Resumo:

An extensive chloride profiling program was undertaken on concrete pier stems erected in the vicinity of the Dornoch Bridge located at the Dornoch Firth in Northeast Scotland. The pier stems were 2 m (6.562 ft) high and octagonal in plan with 0.66 m (2.165 ft) wide faces. The piers were constructed in sets of three with the lowest of each set in the tidal zone and the highest in the atmospheric zone. The pier stems were placed in such a way that they would represent the exposure conditions of the actual bridge piers of the Dornoch Bridge. In all, six of the pier stems were made using plain ordinary portland cement (OPC) concrete (with three of these having the surface treated with silane); the remaining three pier stems had a concrete containing caltite as an additive. Three exposurezones were studied: the tidal zone, the splash zone, and the atmospheric zone. The tidal zone was further subdivided into two levels defined as low-level and high-level. Chloride profiles were obtained from the different regimes over a period of 7 years for all nine pier stems. This paper describes the nature of chloride ingress and the usefulness of diffusion parameters in classifying each exposure regimes. Furthermore, the effectiveness of silane and caltite in protecting concrete from chloride ingress in different exposure zones was studied.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

This paper presents the experimental results of loading tests on two 18m span tapered member portal frames designed to BS 5950. Deflection test results for vertical, lateral and combined loading cases are compared with the predictions given by elastic analysis to BS 5950 and shown to be favourable. The predicted ultimate capacities and modes of failure, which were by lateral-torsional buckling of the columns, were also found to agree with the experimental behaviour. It was found that the method of modelling the tapered members as a series of prismatic elements gave good comparison with test results.