89 resultados para SE(T) SPECIMEN


Relevância:

10.00% 10.00%

Publicador:

Resumo:

Two nitride-strengthened reduced activation ferritic/martensitic (RAFM) steels with different Mn contents were investigated. The experimental steels were designed based on the chemical composition of Eurofer 97 steel but the C content was reduced to an extremely low level. Microstructure observation and hardness tests showed that the steel with low Mn content (0.47 wt.%) could not obtain a full martensitic microstructure due to the inevitable δ-ferrite independent of cooling rate after soaking. This steel showed similar room temperature strength and higher strength at 600 °C, but lower impact toughness, compared with Eurofer 97 steel. Fractography of the Charpy impact specimen revealed that the low room temperature toughness should be related to the Ta-rich inclusions initiating the cleavage fracture. The larger amount of V-rich nitrides and more dissolved Cr in the matrix could be responsible for the strength being similar to Eurofer 97 steel. In the second steel developed from the first steel by increasing the Mn content from 0.47 wt.% to 3.73 wt.%, a microstructure of full martensite could be obtained.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

The microstructure evolution of a 10Cr ferritic/martensitic heat-resistant steel during creep at 600°C was investigated in this work. Creep tests demonstrated that the 10Cr steel had higher creep strength than conventional ASME-P92 steel at 600°C. The microstructure after creep was studied by transmission electron microscopy, scanning electron microscopy and electron probe microanalysis. It was revealed that the martensitic laths were coarsened with time and eventually developed into subgrains after 8354 h. Laves phase was observed to grow and cluster along the prior austenite grain boundaries during creep and caused the fluctuation of solution and precipitation strengthening effects, which was responsible for the two slope changes on the creep rupture strength vs rupture time curve. It was also revealed that the microstructure evolution could be accelerated by stress, which resulted in the lower hardness in the deformed part of the creep specimen, compared with the aging part.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

The mechanical response of Polyethylene Terephthalate (PET) in elongation is strongly dependent on temperature, strain and strain rate. Near the glass transition temperature Tg, the stress-strain curve presents a strain softening effect vs strain rate but a strain hardening effect vs strain under conditions of large deformations. The main goal of this work is to propose a viscoelastic model to predict the PET behaviour when subjected to large deformations and to determine the material properties from the experimental data. To represent the non–linear effects, an elastic part depending on the elastic equivalent strain and a non-Newtonian viscous part depending on both viscous equivalent strain rate and cumulated viscous strain are tested. The model parameters can then be accurately obtained trough a comparison with the experimental uniaxial and biaxial tests. The in?uence of the temperature on the viscous part is also modelled and an evaluation of the adiabatic self heating of the specimen is compared to experimental results.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

False-positive PCR results usually occur as a consequence of specimen-to-specimen or amplicon-to-specimen contamination within the laboratory. Evidence of contamination at time of specimen collection linked to influenza vaccine administration in the same location as influenza sampling is described. Clinical, circumstantial and laboratory evidence was gathered for each of five cases of influenza-like illness (ILI) with unusual patterns of PCR reactivity for seasonal H1N1, H3N2, H1N1 (2009) and influenza B viruses. Two 2010 trivalent influenza vaccines and environmental swabs of a hospital influenza vaccination room were also tested for influenza RNA. Sequencing of influenza A matrix (M) gene amplicons from the five cases and vaccines was undertaken. Four 2009 general practitioner (GP) specimens were seasonal H1N1, H3N2 and influenza B PCR positive. One 2010 GP specimen was H1N1 (2009), H3N2 and influenza B positive. PCR of 2010 trivalent vaccines showed high loads of detectable influenza A and B RNA. Sequencing of the five specimens and vaccines showed greatest homology with the M gene sequence of Influenza A/Puerto Rico/8/1934 H1N1 virus (used in generation of influenza vaccine strains). Environmental swabs had detectable influenza A and B RNA. RNA detection studies demonstrated vaccine RNA still detectable for at least 66 days. Administration of influenza vaccines and clinical sampling in the same room resulted in the contamination with vaccine strains of surveillance swabs collected from patients with ILI. Vaccine contamination should therefore be considered, particularly where multiple influenza virus RNA PCR positive signals (e.g. H1N1, H3N2 and influenza B) are detected in the same specimen.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

An imaging microscope, comprising a Schwarzchild condenser and a zone-plate optical arrangement, has been established on the Vulcan Nd:glass laser system at the Rutherford Appleton Laboratory. Magnified images of simple test structures have been taken in x-ray transmission in a single subnanosecond laser shot by using doublet x-ray laser radiation at 23.2 and 23.6 nm from collisionally pumped Ne-like germanium. Image resolutions of approximately 0.15 mum have been measured. The results are a proof of principle and demonstrate that images of potentially suboptical resolution and of specimen regions that are destroyed on passage of the x-ray beam can be taken successfully using the Vulcan x-ray laser.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

A diminutive species of Aglaothamnion (Ceramiaceae, Rhodophyta), A. diaphanum sp. nov., is described from Brittany (Atlantic France), the Isles of Scilly (off S.W. England) and western Ireland. Aglaothamnion diaphanum is confined to the sublittoral zone, where it grows almost exclusively on algae and sessile animals attached to hard substrata. Thalli are delicate, and branched distichously in one plane. The main axes are ecorticate but may form loose non-corticating rhizoidal filaments. The lateral branches bear a characteristic, regularly alternate distichous series of branchlets, the first of which is always adaxial. All vegetative cells are uninucleate. The majority of field-collected plants bear only bisporangia, but a few bisporangial plants also form spermatangia; some male plants and a single female specimen have been collected. The spermatangial branchlets consist of 3-5 spermatangial mother cells each bearing 2-4 spermatangia, which are constricted around a central nucleus. None of the U-shaped carpogonial branches showed any sign of fertilization, and the gametangia appear to be non-functional. The bisporangia are ovoid and contain two uninucleate spores separated by an oblique curved wall. The occurrence of bisporangia and the lack of adherent cortication distinguish A. diaphanum from two similar species, Aglaothamnion bipinnatum (P. Crouan et H. Crouan) Feldmann-Mazoyer and Aglaothamnion decompositum (J. Agardh) Halos. The life history in culture of French and Irish isolates of A. diaphanum consists of a series of bisporangial generations, a single plant of which also formed spermatangia. Apical cells of bisporophytes are haploid (n = c. 32), but the first division of meiosis, with chromosome pairing and crossing over, occurs in dividing bisporocytes. The germinating bispores are haploid. Endodiploidization may occur in the early stages of sporangium development, as in some phycomycete fungi, or in vegetative cells that subsequently give rise to bisporocytes. This is the first demonstration in the red algae of meiotic bisporangia on plants of which the apical cells, at least, are haploid.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

The injection stretch blow moulding process is used to manufacture PET containers used in the soft drinks and carbonated soft drinks industry. The process consists of a test tube like specimen known as a preform which is heated, stretch and blown into a mould to form the container. This research is focused on developing a validated simulation of the process thus enabling manufacturers to design their products in a virtual environment without the need to waste time, material and energy. The simulation has been developed using the commercial FEA package Abaqus and has been validated using state of the art data acquisition system consisting of measurements for preform temperature (inner and outer wall) using a device known as THERMOscan (Figure 1), stretch rod force and velocity, internal pressure and air temperature inside the preform using an instrumented stretch rod and the?exact?timing of when the preform touches the mould wall using contact sensors.? In addition, validation studies have also been performed by blowing a perform without a mould and using high sped imaging technology in cooperation with an advanced digital image correlation system (VIC 3D) to provided new quantitative information on the behaviour of PET during blowing.? The approach has resulted in a realistic simulation in terms of accurate input parameters, preform shape evolution and prediction of final properties.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

A review of medical records of 45 of 53 hospitalised patients with positive cultures for CTX-M type ESBL-producing Escherichia coli between 01 January and 31 May 2004 was conducted. The mean age of the population studied was 73.1 (+/-14.6) years and the majority (55.6%) had been under the care of the internal medicine or elderly care service. In the majority (77.8%) of instances the isolate was attributed to a clinical infection rather than colonisation and the commonest clinical specimen to yield the organism was urine, which was positive in 57.8% of patients. Acquisition of the organism was categorised as nosocomial in 68.9% of patients; in this subgroup, the median duration of inpatient stay prior to recovery of the organism was 24 (range 3-240) days. Haemodialysis-dependence was the most common of the comorbidities evaluated. The mean number of antibiotics prescribed per patient in the 30 days prior to first isolation of the organism was 1.7 (range 0-4). Furthermore, the mean number of antibiotic-days exposure per patient during this period was 13.9 (range 0-48). The most frequently received class of antibiotic was beta-lactam/beta-lactamase inhibitor combinations. Of 35 infections, 26 (74.2%) were successfully treated. Overall 12 patients with infection died (34.3%); attributable mortality was presumed in seven (20%).

Relevância:

10.00% 10.00%

Publicador:

Resumo:

A specimen of emollient cream, which was observed to be contaminated peripherally with a filamentous fungus was examined for the presence of fungi and the resulting fungal colonies were examined phenotypically and genotypically. Subsequent DNA extraction and PCR amplification of the large internal transcribed spacer region [ITS1-5.8S-ITS2] yielded an amplicon of 512 bp. Sequence analysis identified this as Alternaria alternata at the 100% homology level with all 512/512 bases called. This organism has been previously reported as a cause of opportunistic infections involving skin and immunocompromised patients. This is the first report of an emollient cream as a source of this organism. It highlights the need for proper management of such preparations in order to minimize the potential spread of fungi to susceptible patient populations.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

In contrast to the multitude of studies on fungal PCR assay methods, little work has been reported evaluating Candida PCR performance when using whole blood compared with serum in candidaemic patients. Here, a comparison of the performance of whole-blood and serum specimens using a set of real-time PCR Candida species assays is described. Specimens were collected prospectively from non-neutropenic adults who were recruited to a diagnostic clinical trial, the primary purpose of which was to verify the performance of the assays using serum; in all, 104 participants also had whole-blood specimens submitted for analysis in addition to the serum specimen. Of these participants, 10 had laboratory-confirmed candidaemia and 94 were categorized as being 'unlikely' to have invasive Candida infection. PCR results from the whole-blood specimens are presented here and compared with the results from serum specimens in this subgroup among whom both specimen types were obtained contemporaneously. All participants with candidaemia were PCR-positive from serum samples; however, only seven were PCR-positive from whole blood. All specimens from patients in the 'unlikely' category were PCR-negative in both types of specimen. Moreover, DNA extraction from serum required 1 h; extraction from whole blood required approximately 3 h. These data tentatively suggest that, overall, serum is an appropriate specimen for Candida PCR for detection of candidaemia in non-neutropenic adults.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

This limited experimental investigation examined the relationships between the compressive strengths of cubes, cylinders, cores and the estimated compressive strengths derived from pull-off tests for a relatively low-strength structural-grade concrete (<35 N/mm2). Test specimens were cast and tested at 7, 14, 28, 56 and 84 days. The relationships of the trends of the test results to the trends of results of standard cube specimens and standard cylinder specimens were compared. It was found that the mean strength of each type of specimen tended to increase as a function of the natural logarithm of the specimen age. The mean strength of cylinders of length/diameter ratio 2.0 was found to be slightly greater (by about 7.5%) than the generally accepted value of 80% of the mean cube strength. Core results were corrected using correction factors defined in BS 6089 and the UK national annex to BS EN 12504-1. The mean corrected cube strength of cores taken from cubes was approximately 12% greater than the mean companion cube strength. The mean corrected cylinder strength of cores taken from cubes was approximately 5% greater than the mean companion cylinder strength. The potential cube and cylinder strengths of cores taken from slabs cured under different environmental conditions correlated well with companion cube and cylinder strengths respectively at 28 days. The pull-off test results gave a variable but, on average, slightly conservative estimate of the cube compressive strength of the relatively low-strength structural-grade concrete, using a simple general linear estimated compressive cube strength to tensile strength correlation factor of 10.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

In this work, the use of a compliant web design for improved damage tolerance in stiffener run-outs is investigated. Firstly, a numerical study that incorporates the possibility of debonding and delamination (using VCCT) is used to select a favourable compliant run-out configuration. Then, three different configurations are compared to establish the merits of the compliant design: a baseline configuration, a configuration with optimised tapering and the selected compliant configuration. The performance of these configurations, in terms of strength and damage tolerance, was compared numerically using a parametric finite element analysis. The energy release rates for debonding and delamination, for different crack lengths across the specimen width, were used for this comparison. The three configurations were subsequently manufactured and tested. In order to monitor the failure process, acoustic emission (AE) equipment was used and proved valuable in the detection and analysis of failure. The predicted failure loads, based on the energy release rates, showed good agreement with the experiments, particularly when the distribution of energy release rate across the width of the specimen was taken into account. As predicted numerically, the compliant configuration failed by debonding and showed improved damage tolerance compared to the baseline and tapered stiffener run-outs.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

The recent trend of incorporating more composite material in primary aircraft structures has highlighted the vulnerability of stiffened aerostructures to through-thickness stresses, which may lead to delamination and debonding at the skin-stiffener interface, leading to collapse. Stiffener runout regions are particularly susceptible to this problem and cannot be avoided due to the necessity to terminate stiffeners at rib intersections or at cutouts, interrupting the stiffener load path. In this paper, experimental tests relating to two different stiffener runout specimens are presented and the failure modes of both specimens are discussed in detail. A thinner-skinned specimen showed sudden and unstable crack propagation, while a thicker-skinned specimen showed initially unstable but subsequent stable crack growth. Detailed finite element models of the two specimens are developed, and it is shown how such models can explain and predict the behaviour and failure mode of stiffener runouts. The models contain continuum shell elements to model the skin and stiffener, while cohesive elements using a traction-separation law are placed at the skin-stiffener interface to effectively model the debonding which promotes structural failure.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

A numerical and experimental investigation on the mode-I intralaminar toughness of a hybrid plain weave composite laminate manufactured using resin infusion under flexible tooling (RIFT) process is presented in this paper. The pre-cracked geometries consisted of overheight compact tension (OCT), double edge notch (DEN) and centrally cracked four-point-bending (4PBT) test specimens. The position as well as the strain field ahead of the crack tip during the loading stage was determined using a digital speckle photogrammetry system. The limitation on the applicability of the standard data reduction schemes for the determination of intralaminar toughness of composite materials is presented and discussed. A methodology based on the numerical evaluation of the strain energy release rate using the J-integral method is proposed to derive new geometric correction functions for the determination of the stress intensity factor for composites. The method accounts for material anisotropy and finite specimen dimension effects regardless of the geometry. The approach has been validated for alternative non-standard specimen geometries. A comparison between different methods currently available for computing the intralaminar fracture toughness in composite laminates is presented and a good agreement between numerical and experimental results using the proposed methodology was obtained. 

Relevância:

10.00% 10.00%

Publicador:

Resumo:

The development of the next generation of civil and military transport aircraft will inevitably see an increased use of advanced carbon fibre composite material in the primary structure if performance targets are to be met. One concern in this development is the vulnerability of co-cured and co-bonded stiffened structures to through-thickness stresses at the skin-stiffener interfaces, particularly in stiffener runout regions. These regions are a consequence of the requirement to terminate stiffeners at cutouts, rib intersections, or other structural features which interrupt the stiffener load path.

This work presents the results of an experimental programme investigating the failure of thick-sectioned stiffener runout specimens loaded in uniaxial compression. For all tests, failure initiated at the edge of the runout and propagated across the skin-stiffener interface. It was found that the failure load of each specimen was greatly influenced by intentional changes in the geometric features of these specimens. High frictional forces at the edge of the runout were also deduced from a fractographic analysis, indicating a predominantly Mode II initial failure mode.