42 resultados para RAPID METHODS


Relevância:

30.00% 30.00%

Publicador:

Resumo:

Pseudomonas aeruginosa genotyping relies mainly upon DNA fingerprinting methods, which can be subjective, expensive and time-consuming. The detection of at least three different clonal P. aeruginosa strains in patients attending two cystic fibrosis (CF) centres in a single Australian city prompted the design of a non-gel-based PCR method to enable clinical microbiology laboratories to readily identify these clonal strains. We designed a detection method utilizing heat-denatured P. aeruginosa isolates and a ten-single-nucleotide polymorphism (SNP) profile. Strain differences were detected by SYBR Green-based real-time PCR and high-resolution melting curve analysis (HRM10SNP assay). Overall, 106 P. aeruginosa sputum isolates collected from 74 patients with CF, as well as five reference strains, were analysed with the HRM10SNP assay, and the results were compared with those obtained by pulsed-field gel electrophoresis (PFGE). The HRM10SNP assay accurately identified all 45 isolates as members of one of the three major clonal strains characterized by PFGE in two Brisbane CF centres (Australian epidemic strain-1, Australian epidemic strain-2 and P42) from 61 other P. aeruginosa strains from Australian CF patients and two representative overseas epidemic strain isolates. The HRM10SNP method is simple, is relatively inexpensive and can be completed in <3 h. In our setting, it could be made easily available for clinical microbiology laboratories to screen for local P. aeruginosa strains and to guide infection control policies. Further studies are needed to determine whether the HRM10SNP assay can also be modified to detect additional clonal strains that are prevalent in other CF centres.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Rapid immunoanalytical screening of food and environmental samples for small molecular weight (hapten) biotoxin contaminations requires the production of antibody reagents that possess the requisite sensitivity and specificity. To date animal-derived polyclonal (pAb) and monoclonal (mAb) antibodies have provided the binding element of the majority of these assays but recombinant antibodies (rAb) isolated from in vitro combinatorial phage display libraries are an exciting alternative due to (1) circumventing the need for experimental animals, (2) speed of production in commonly used in vitro expression systems and (3) subsequent molecular enhancement of binder performance. Short chain variable fragments (scFv) have been the most commonly employed rAb reagents for hapten biotoxin detection over the last two decades but antibody binding fragments (Fab) and single domain antibodies (sdAb) are increasing in popularity due to increased expression efficiency of functional binders and superior resistance to solvents. rAb-based immunochromatographic assays and surface plasmon resonance (SPR) biosensors have been reported to detect sub-regulatory levels of fungal (mycotoxins), marine (phycotoxins) and aquatic biotoxins in a wide range of food and environmental matrices, however this technology has yet to surpass the performances of the equivalent mAb- and pAb-based formats. As such the full potential of rAb technology in hapten biotoxin detection has yet to be achieved, but in time the inherent advantages of engineered rAb are set to provide the next generation of ultra-high performing binder reagents for the rapid and specific detection of hapten biotoxins.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Leptospirosis is a globally important zoonotic infection caused by spirochaetes of the genus Leptospira. It is transmitted to humans by direct contact with infected animals or indirectly via contaminated water. It is mainly a problem of the resource-poor developing countries of the tropical and sub-tropical regions of the world but outbreaks due to an increase in travel and recreational activities have been reported in developed and more industrialized areas of the world. Current methods of diagnosis are costly, time-consuming and require the use of specialized laboratory equipment and personnel. The purpose of this paper is to report the validation of the 'Leptorapide®' test (Linnodee Ltd, Northern Ireland) for the diagnosis of human leptospirosis. It is a simple one-step latex agglutination assay performed using equal volumes of serum sample and antigen-bound latex beads. Evidence of leptospiral antibodies is determined within minutes. Agglutination is scored on a scale of 1-5 and the results interpreted using a score card provided with the kit. Validation has been performed with a large sample size obtained from individuals originating from various parts of the world including Brazil and India. The test has shown sensitivity and specificity values of 97·1% and 94·0%, respectively, relative to the microscopic agglutination test. The results demonstrate that Leptorapide offers a cost-effective and accurate alternative to the more historical methods of antibody detection.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

High-frequency fluctuations are observed with the Rapid Oscillations in the Solar Atmosphere (ROSA) instrument (Jess et al. 2010, Solar Phys, 261, 363) at the Dunn Solar Telescope. This can produce simultaneous observations in up to six channels, at different heights in the photosphere and chromosphere, at an unprecedentedly high cadence of 0.5 seconds, and at a spatial resolution of 100 km after photometrically correct speckle reconstruction. Here we concentrate on observations at two levels. The first is in the G-band of the CH radical at 4305.5Å, bandpass 9.2Å, with height of formation z <250 km at a cadence of 0.525 sec corresponding to Nyquist frequency 950 mHz. The second is in the Ca II K-line core at 3933.7Å, bandpass 1.0Å, with height of formation z <1300 km, and cadence 4.2 sec giving Nyquist frequency 120 mHz. The data span 53 min, and the maximum field of view is 45 Mm. The data were taken on 28 May 2009 in internetwork and network near disk center. Using both Fourier and Morlet wavelet methods we find evidence in the G-band spectra for intensity fluctuations above noise out to frequencies f >> 100 mHz. The K-line signal is noisier and is seen only for f <50 mHz. With wavelet techniques we find that G-band spectral power with 20 <f <100 mHz is clearly concentrated in the intergranular lanes and especially at the locations of magnetic elements indicated by G-band bright points. This wavelet power is highly intermittent in time. By cross-correlating the data we find that pulses of high-frequency G-band power in the photosphere tend to be followed by increases in K-line emission in the chromosphere with a time lag of about 2 min.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

A single-step lateral flow immunoassay (LFIA) was developed and validated for the rapid screening of paralytic shellfish toxins (PSTs) from a variety of shellfish species, at concentrations relevant to regulatory limits of 800 μg STX-diHCl equivalents/kg shellfish meat. A simple aqueous extraction protocol was performed within several minutes from sample homogenate. The qualitative result was generated after a 5 min run time using a portable reader which removed subjectivity from data interpretation. The test was designed to generate noncompliant results with samples containing approximately 800 μg of STX-diHCl/kg. The cross-reactivities in relation to STX, expressed as mean ± SD, were as follows: NEO: 128.9% ± 29%; GTX1&4: 5.7% ± 1.5%; GTX2&3: 23.4% ± 10.4%; dcSTX: 55.6% ± 10.9%; dcNEO: 28.0% ± 8.9%; dcGTX2&3: 8.3% ± 2.7%; C1&C2: 3.1% ± 1.2%; GTX5: 23.3% ± 14.4% (n = 5 LFIA lots). There were no indications of matrix effects from the different samples evaluated (mussels, scallops, oysters, clams, cockles) nor interference from other shellfish toxins (domoic acid, okadaic acid group). Naturally contaminated sample evaluations showed no false negative results were generated from a variety of different samples and profiles (n = 23), in comparison to reference methods (MBA method 959.08, LC-FD method 2005.06). External laboratory evaluations of naturally contaminated samples (n = 39) indicated good correlation with reference methods (MBA, LC-FD). This is the first LFIA which has been shown, through rigorous validation, to have the ability to detect most major PSTs in a reliable manner and will be a huge benefit to both industry and regulators, who need to perform rapid and reliable testing to ensure shellfish are safe to eat.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Background Rapid Response Systems (RRS) consist of four interrelated and interdependent components; an event detection and trigger mechanism, a response strategy, a governance structure and process improvement system. These multiple components of the RRS pose problems in evaluation as the intervention is complex and cannot be evaluated using a traditional systematic review. Complex interventions in healthcare aimed at changing service delivery and related behaviour of health professionals require a different approach to summarising the evidence. Realist synthesis is such an approach to reviewing research evidence on complex interventions to provide an explanatory analysis of how and why an intervention works or doesn’t work in practice. The core principle is to make explicit the underlying assumptions about how an intervention is suppose to work (ie programme theory) and then use this theory to guide evaluation. Methods A realist synthesis process was used to explain those factors that enable or constrain the success of RRS programmes. Results The findings from the review include the articulation of the RRS programme theories, evaluation of whether these theories are supported or refuted by the research evidence and an evaluation of evidence to explain the underlying reasons why RRS works or doesn’t work in practice. Rival conjectured RRS programme theories were identified to explain the constraining factors regarding implementation of RRS in practice. These programme theories are presented using a logic model to highlight all the components which impact or influence the delivery of RRS programmes in the practice setting. The evidence from the realist synthesis provided the foundation for the development of hypothesis to test and refine the theories in the subsequent stages of the Realist Evaluation PhD study [1]. This information will be useful in providing evidence and direction for strategic and service planning of acute care to improve patient safety in hospital. References: McGaughey J, Blackwood B, O’Halloran P, Trinder T. J. & Porter S. (2010) Realistic Evaluation of Early Warning Systems and the Acute Life-threatening Events – Recognition and Treatment training course for early recognition and management of deteriorating ward-based patients: research protocol. Journal of Advanced Nursing 66 (4), 923-932.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Current methods for measuring deoxyribonucleoside triphosphates (dNTPs) employ reagent and labor-intensive assays utilizing radioisotopes in DNA polymerase-based assays and/or chromatography-based approaches. We have developed a rapid and sensitive 96-well fluorescence-based assay to quantify cellular dNTPs utilizing a standard real-time PCR thermocycler. This assay relies on the principle that incorporation of a limiting dNTP is required for primer-extension and Taq polymerase-mediated 5-3' exonuclease hydrolysis of a dual-quenched fluorophore-labeled probe resulting in fluorescence. The concentration of limiting dNTP is directly proportional to the fluorescence generated. The assay demonstrated excellent linearity (R(2) > 0.99) and can be modified to detect between ∼0.5 and 100 pmol of dNTP. The limits of detection (LOD) and quantification (LOQ) for all dNTPs were defined as <0.77 and <1.3 pmol, respectively. The intra-assay and inter-assay variation coefficients were determined to be <4.6% and <10%, respectively with an accuracy of 100 ± 15% for all dNTPs. The assay quantified intracellular dNTPs with similar results obtained from a validated LC-MS/MS approach and successfully measured quantitative differences in dNTP pools in human cancer cells treated with inhibitors of thymidylate metabolism. This assay has important application in research that investigates the influence of pathological conditions or pharmacological agents on dNTP biosynthesis and regulation.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

The European Cystic Fibrosis Society Clinical Trial Network (ECFS-CTN) has established a Standardization Committee to undertake a rigorous evaluation of promising outcome measures with regard to use in multicentre clinical trials in cystic fibrosis (CF). The aim of this article is to present a review of literature on clinimetric properties of the infant raised-volume rapid thoracic compression (RVRTC) technique in the context of CF, to summarise the consensus amongst the group on feasibility and answer key questions regarding the promotion of this technique to surrogate endpoint status.

METHODS: A literature search (from 1985 onwards) identified 20 papers that met inclusion criteria of RVRTC use in infants with CF. Data were extracted and tabulated regarding repeatability, validity, correlation with other outcome measures, responsiveness and reference values. A working group discussed the tables and answered 4 key questions.

RESULTS: Overall, RVRTC in particular forced expiratory volume in 0.5s, showed good clinimetric properties despite presence of individual variability. Few studies showed a relationship between RVRTC and inflammation and infection, and to date, data remains limited regarding the responsiveness of RVRTC after an intervention. Concerns were raised regarding feasibility in multi-centre studies and availability of reference values.

CONCLUSION: The ECFS-CTN Working Group considers that RVRTC cannot be used as a primary outcome in clinical trials in infants with CF before universal standardization of this measurement is achieved and implementation of inter-institutional networking is in place. We advise its use currently in phase I/II trials and as a secondary endpoint in phase III studies. We emphasise the need for (1) more short-term variability and longitudinal 'natural history' studies, and (2) robust reference values for commercially available devices.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Background: A novel lateral flow, immunochromatographic assay (LFD) specific for Mycobacterium bovis, the cause of bovine tuberculosis and zoonotic TB, was recently developed at Queen’s University Belfast. The LFD detects whole M. bovis cells, in contrast to other commercially available LFD tests (BD MGITTM TBc ID, SD Bioline TB Ag MPT 64, Capilia TB-Neo kit) which detect MPT64 antigen secreted during growth. The new LFD test has been evaluated in the veterinary context, and its specificity for M. bovis in the broadest sense (i.e. subsp. bovis, subsp. caprae and BCG) and sensitivity to detect M. bovis in positive MGIT™ liquid cultures was demonstrated comprehensively.
Methods: Preliminary work was carried out by researchers at Queen’s University Belfast to optimise sputum sample preparation, estimate the limit of detection (LOD) of the LFD with M. bovis-spiked sputum samples, and check LFD specificity by testing a broad range of non-tuberculous Mycobacterium spp. (NTM) and other bacterial genera commonly encountered in sputum samples (Haemophilus, Klebsiella, Pseudomonas, Staphylococcus). In the Cameroon laboratory direct detection of M. bovis in human sputa was attempted, and 50 positive sputum MGIT™ cultures and 33 cultures of various Mycobacterium spp. originally isolated from human sputa were tested.
Results: Sputum sample preparation consisted of digestion with 1% NALC for 30 min, centrifugation at 3000g for 20 min, PBS wash, centrifugation again, and pellet resuspended in KPL blocking buffer before 100 µl was applied to the LFD. The LOD of the LFD applied to M. bovis-spiked sputum was estimated to be 104 CFU/ml. A small number of confirmed Ziehl-Neelsen ‘3+’ M. bovis positive sputum samples were tested directly but no positive LFD results were obtained. All of the sputum MGIT™ cultures and mycobacterial cultures (including M. tuberculosis, M. africanum, M. bovis, M. intracellulare, M. scrofulaceum, M. fortuitum, M. peregrinum, M. interjectum) tested LFD negative when read after 15 min except for the M. bovis cultures, thereby confirming specificity of LFD for M. bovis in the clinical microbiology context.
Conclusions: Results indicate that the ‘Rapid-bTB’ LFD is a very specific test, able to differentiate M. bovis from M. tuberculosis, M. africanum, and a range of NTM isolated from human sputa in MGITTM liquid cultures. However, the LFD lacks sufficient sensitivity to be applied earlier in the diagnostic process to directly test human sputa.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

A single-step lateral flow immunoassay was developed and validated to detect okadaic acid (OA) and dinophysis toxins (DTXs), which cause diarrhetic shellfish poisoning. The performance characteristics of the test were investigated, in comparison to reference methods (liquid chromatography tandem mass spectrometry and/or bioassay), using both spiked and naturally contaminated shellfish. A portable reader was used to generate a qualitative result, indicating the absence or presence of OA-group toxins, at concentrations relevant to the maximum permitted level (MPL). Sample homogenates could be screened in 20 min (including extraction and assay time) for the presence of free toxins (OA, DTX1, DTX2). DTX3 detection could be included with the addition of a hydrolysis procedure. No matrix effects were observed from the species evaluated (mussels, scallops, oysters, and clams). Results from naturally contaminated samples (n = 72) indicated no false compliant results and no false noncompliant results at <50% MPL. Thus, the development of a new low-cost but highly effective tool for monitoring a range of important phycotoxins has been demonstrated.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

PURPOSE: To determine whether optical aberrations caused by cataract can be detected and quantified objectively using a newly described focus detection system (FDS). SETTING: The Wilmer Opthalmological Institute, The Johns Hopkins University School of Medicine, Baltimore, Maryland, USA. METHODS: The FDS uses a bull's eye photodetector to measure the double-pass blur produced from a point source of light. To determine the range and level of focus, signals are measured with a series of trial lenses in the light path selected to span the point of best focus to generate focus curves. The best corrected visual acuity (BCVA), refractive error, lens photograph grades, and FDS signals were obtained in 18 patients scheduled to have cataract surgery. The tests were repeated 6 weeks after surgery. RESULTS: The mean FDS outcome measures improved after cataract surgery, with increased peak height (P=.001) and decreased peak width (P=.001). Improvement in signal strength (integral of signal within +/-1.5 diopters of the point of best focus) strongly correlated with improvement in peak height (R(2)=.88, P<.0001) and photographic cataract grade (R(2)=.72, P<.0001). The mean BCVA improved from 20/50 to 20/26 (P<.0001). The improvement in BCVA correlated more closely with FDS signal strength (R(2)=.44, P=.001) than with cataract grade (R(2)=.25, P=.06). CONCLUSIONS: Improvement in FDS outcome measures correlated with cataract severity and improvement in visual acuity. This objective approach may be useful in long-term studies of cataract progression.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

INTRODUCTION: Between 1998 and 2010, S. Typhi was an uncommon cause of bloodstream infection (BSI) in Blantyre, Malawi and it was usually susceptible to first-line antimicrobial therapy. In 2011 an increase in a multidrug resistant (MDR) strain was detected through routine bacteriological surveillance conducted at Queen Elizabeth Central Hospital (QECH).

METHODS: Longitudinal trends in culture-confirmed Typhoid admissions at QECH were described between 1998-2014. A retrospective review of patient cases notes was conducted, focusing on clinical presentation, prevalence of HIV and case-fatality. Isolates of S. Typhi were sequenced and the phylogeny of Typhoid in Blantyre was reconstructed and placed in a global context.

RESULTS: Between 1998-2010, there were a mean of 14 microbiological diagnoses of Typhoid/year at QECH, of which 6.8% were MDR. This increased to 67 in 2011 and 782 in 2014 at which time 97% were MDR. The disease predominantly affected children and young adults (median age 11 [IQR 6-21] in 2014). The prevalence of HIV in adult patients was 16.7% [8/48], similar to that of the general population (17.8%). Overall, the case fatality rate was 2.5% (3/94). Complications included anaemia, myocarditis, pneumonia and intestinal perforation. 112 isolates were sequenced and the phylogeny demonstrated the introduction and clonal expansion of the H58 lineage of S. Typhi.

CONCLUSIONS: Since 2011, there has been a rapid increase in the incidence of multidrug resistant, H58-lineage Typhoid in Blantyre. This is one of a number of reports of the re-emergence of Typhoid in Southern and Eastern Africa. There is an urgent need to understand the reservoirs and transmission of disease and how to arrest this regional increase.