73 resultados para Passive Margin
Resumo:
This paper addresses the theoretical aspects of passive intermodulation (PIM) generation in printed transmission lines. In order to elucidate the mechanisms of PIM generation, a new model of the transmission line length with distributed nonlinearity is proposed. The developed model has been validated by the near-field measurements of PIM product distributions along the microstrip lines. The contributions of nonlinear mixing, power dissipation, and load matching to PIM products have been analyzed in detail. The obtained results reveal the fundamental properties of PIM generation in finite lengths of printed lines with distributed non-linearity and identify possible means for PIM mitigation. It was shown for the first time that the reverse PIM products in a matched transmission line with distributed nonlinearity are generated due to nonlinear scattering. © 2008 IEEE.
Resumo:
This paper discusses whether or not Strasbourg organs have created principled criteria governing the use of the doctrine within the context of free speech and public morals. The first part of the paper gives an overview of the doctrine and further examines how the doctrine has evolved within the European context. Part II focuses on the rationale behind the doctrine and discusses the legitimacy of the doctrine in light of its application to various forms of free speech. Part III covers one of the most problematic applications of the doctrine in matters concerning public morality, where Contracting States have a wide margin of appreciation. This part will discuss whether or not the “lack of European consensus” criterion is an elusive concept that might create a risk of abuse in the application of the doctrine. The paper concludes that while margin of appreciation today serves as a flexible instrument between the local necessities and the universal application of human rights, the imprecise and contradictory points might lead to its potential abuse that might endanger its future existence.
Resumo:
To use profilometry to assess the margin surface profile of all-ceramic crowns (ACC’s) at try-in and 1-week after cementation with dual-cured resin (DC, RelyX ARC, 3 M ESPE, St. Paul, MN, USA), self-adhesive dual-cured resin (SADC, RelyX Unicem, 3 M ESPE), light-cured resin (LC, RelyX Veneer, 3 M ESPE) or chemically cured resin-modified glass ionomer (RMGI, RelyX Luting Plus, 3 M ESPE) luting cement. Methods: Forty, sound, extracted, human, premolar teeth underwent a standardised preparation for ACC’s. IPS Empress (Ivoclar-Vivadent, Liechtenstein) crowns of standard dimensions were fabricated and 10 luted with each cement and stored in water for 7 days. Three groups of serial profiles were taken, the first of the tooth preparation, the second of the crown margins at try-in and lastly of the crown margins after cementation and 7 days water storage. Results: There were no significant differences in the crown margin surface profile between the four cement groups at try-in. The change in crown margin position between try-in and post-cementation was significantly greater for DC than for LC and RMGI. SADC was not significantly different to the other cements. There were no significant differences in the crown margin extensions between the four cement groups, however most of the IPS Empress ACC’s in this study were underextended but this was not statistically significant. Conclusions: IPS Empress ACC’s seated more fully with LC and RMGI than with DC cement
Resumo:
An experimental investigation of the effect of conductor-to-substrate interface on distributed passive intermodulation (PIM) generation in printed microstrip lines has been undertaken using the custom-designed microwave laminates with removed surface bonding layers and with the commercial adhesion promotion applied to the conductor underside. The study of long-term stability of PIM performance of the printed circuits is reported for the first time. The comprehensive measurement results, observations of the selfimprovement of the PIM performance and the effect of panel bending on PIM generation in printed boards with different finishing are presented. A consistent physical interpretation of the observed phenomena is proposed. The results of this study provide new important considerations for the design and characterisation of low-PIM printed circuits.
Resumo:
Ground vehicle tests have been performed to evaluate the performance of a Passive Millimeter Wave (PMMW) imager in reduced visibility conditions and in particular, the ability to detect power lines and cables. A PMMW imager was
compared with Long Wave Infrared (LWIR) and visible imaging cameras. The three sensors were mounted on a Land Rover, together with GPS and digital recording system. All three sensors plus the GPS data were recorded simultaneously in order to provide direct comparisons. The vehicle collected imagery from a number of sites in the vicinity of Malvern, UK, in January, 2008. Imagery was collected both while the vehicle was stationary at specific sites
and while it was moving. Weather conditions during the data collection included clear, drizzle, rain and fog. Imagery was collected during the day, at night, and during dusk/dawn transition periods. The PMMW imager was a prototype which operated at 94 GHz and was based on a conically scanned folded Schmidt camera and the LWIR and visible sensors were commercial off the shelf items.
Resumo:
Results are presented from a trial in which a real-time passive millimetre-wave camera was mounted on a landing craft. The vessel was operated on rivers in the UK, and imagery of surrounding terrain, structures, obstacles and other vessels was obtained. An IR camera was also used, and the differences in signatures of various features are discussed. Opportunities for image fusion are highlighted.
Resumo:
In adults, both active and passive smoking reduce levels of exhaled nitric oxide (eNO); however, to date, passive exposure to environmental tobacco smoke (ETS) has not been shown to affect eNO in children. The authors recruited 174 asthmatic children (96 male, 78 female) and 79 nonasthmatic controls (46 male, 33 female) from a group of children aged 5 to 14 yr who attended a children's hospital for an outpatient visit or elective surgery. Each subject's exposure to ETS was ascertained by questionnaire, and their eNO levels were measured. Asthmatic children had higher eNO levels (ppb) than nonasthmatic children (p = 0.04), and asthmatic children exposed to ETS had significantly lower eNO levels than unexposed children (p = 0.005). Exposure to ETS did not alter eNO levels in nonasthmatic children (p = 0.4). Results of the study suggest that ETS exposure is associated with lower eNO levels among childhood asthmatics. Consequently, ETS exposure may need to be considered when physicians interpret eNO levels in asthmatic children. Further study of the effects of ETS on eNO levels is recommended.