163 resultados para Parsons, Lewis B. (Lewis Baldwin), 1818-1907.


Relevância:

30.00% 30.00%

Publicador:

Resumo:

The construction of short-pulse tunable soft x-ray free electron laser sources based on the self-amplified spontaneous emission process will provide a major advance in capability for dense plasma-related and warm dense matter (WDM) research. The sources will provide 10(13) photons in a 200-fs duration pulse that is tunable from approximately 6 to 100 nm. Here we discuss only two of the many applications made possible for WDM that has been severely hampered by the fact that laser-based methods have been unavailable because visible light will not propagate at electron densities of n(e) greater than or equal to 10(22) cm(-3). The next-generation light sources will remove these restrictions.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Objective: to investigate the effects of tetrahydrocannabinol; THC on human sperm function in vitro. Design: laboratory analysis of sperm motility with and without exposure to THC using computer assisted semen analysis (CASA) and acrosome reaction by fluoroscein isothiocyanate labelled peanut agglutinin (FITC-PNA) staining. Setting: An ART unit in a tertiary medical centre. Patients: semen was obtained from 78 men attending the Regional Fertility Centre, Belfast. Interventions: Sperm were divided into 90% (the best fertilizing potential used in assisted conception) and 45% (the poorer subpopulation) fractions by density centrifugation and incubated with, or without (controls), tetrahydrocannabinol (THC) at concentrations equivalent to therapeutic (0.032�?�¯?�?�­M) and recreational (4.8 and 0.32�?�¯?�?�­M) plasma levels, at 37�?�¯?�?�°C for 3 hours. Main outcome measures: Sperm motility, spontaneous and induced acrosome reactions Results: There was a dose-dependent decrease in percentage progressive motility (-21% at 4.8�??�?�µM, p0.05) in the 90% fraction. The 45% fraction showed a greater decrease in percentage progressive motility (-56% at 4.8�??�?�µM, p=0.011; -23% at 0.32�??�?�µM, p= 0.039; and -28% at 0.032�??�?�µM, p=0.004). A decrease in the straight line velocity; VSL (-10%) and the average path velocity; VAP (-10%) were also observed in the 90% fraction. A significant inhibition (-15% at 4.8�??�?�µM, p=0.04) in spontaneous acrosome reaction was observed in the 90% fraction. The 45% fraction showed a more marked inhibition [-35% (p

Relevância:

30.00% 30.00%

Publicador:

Resumo:

BACKGROUND Diabetes mellitus (DM) is increasing in men of reproductive age. Despite this, the prevalence of diabetes in men attending fertility clinics is largely unknown. Furthermore, studies examining the effects of DM on sperm fertility potential have been limited to conventional semen analysis. METHODS Conventional semen analysis (semen volume, sperm count, motility and morphology) was performed for 27 diabetic (mean age 34 +/- 2 years) and 29 non-diabetic subjects (control group, men undergoing routine infertility investigations, mean age 33 +/- 1 years). Nuclear DNA (nDNA) fragmentation was assessed using the alkaline Comet assay and mitochondrial DNA (mtDNA) deletions by Long-PCR. RESULTS Other than a small, but significant, reduction in semen volume in diabetic men (2.6 versus 3.3 ml; P <0.05), conventional semen parameters did not differ significantly from control subjects. Diabetic subjects had significantly higher mean nDNA fragmentation (53 versus 32%; P <0.0001) and median number of mtDNA deletions (4 versus 3; P <0.05) compared with control subjects. CONCLUSIONS Diabetes is associated with increased sperm nuclear and mtDNA damage that may impair the reproductive capability of these men.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

We report results on the performance of a free-electron laser operating at a wavelength of 13.7 nm where unprecedented peak and average powers for a coherent extreme-ultraviolet radiation source have been measured. In the saturation regime, the peak energy approached 170 J for individual pulses, and the average energy per pulse reached 70 J. The pulse duration was in the region of 10 fs, and peak powers of 10 GW were achieved. At a pulse repetition frequency of 700 pulses per second, the average extreme-ultraviolet power reached 20 mW. The output beam also contained a significant contribution from odd harmonics of approximately 0.6% and 0.03% for the 3rd (4.6 nm) and the 5th (2.75 nm) harmonics, respectively. At 2.75 nm the 5th harmonic of the radiation reaches deep into the water window, a wavelength range that is crucially important for the investigation of biological samples.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

The effects of diabetes mellitus on male reproductive health have not been clearly defined. A previous publication from this group reported significantly higher levels of nuclear DNA fragmentation and mitochondrial DNA deletions in spermatozoa from men with type 1 diabetes. This study compared semen profiles, sperm DNA fragmentation and levels of oxidative DNA modification in spermatozoa of diabetic and non-diabetic men. Semen samples from 12 non-diabetic, fertile men and 11 type 1 diabetics were obtained and subjected to conventional light microscopic semen analysis. Nuclear DNA fragmentation was assessed using an alkaline Comet assay and concentrations of 7,8-dihydro-8-oxo-2-deoxyguanosine (8-OHdG), an oxidative adduct of the purine guanosine, were assessed by high-performance liquid chromatography. Conventional semen profiles were similar in both groups, whilst spermatozoa from type 1 diabetics showed significantly higher levels of DNA fragmentation (44% versus 27%; P < 0.05) and concentrations of 8-OHdG (3.6 versus 2.0 molecules of 8-OHdG per 105 molecules of deoxyguanosine; P < 0.05). Furthermore, a positive correlation was observed between DNA fragmentation and concentrations of 8-OHdG per 105 molecules of deoxyguanosine (rs = 0.7, P < 0.05). The genomic damage evident in spermatozoa of type 1 diabetics may have important implications for their fertility and the outcome of pregnancies fathered by these individuals.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Heterogeneous immobilized ionic liquid catalysts were prepared via grafting of 1,3-dimethyl-3-(3-triethoxysilylpropyl)-imidazolium tetrafluoroborate or bist{(trifluoromethyl)sulfonyl} imide ([NTf2](-)) on silica supports with different surfaces and pore size. In addition to the adsorption-desorption isotherms of nitrogen at -196C, the catalysts were characterized by TG-DTA, XPS, DRIFTS, DR-UV-vis, NMR, and XRD techniques. The catalytic behavior was checked in the acylation of three different sulfonamines: benzenesulfonamine, p-nitrobenzene-sulfonamine, and p-methoxybenzene-sulfonamine with acetic acid, acetic anhydride and maleic anhydride. These tests confirmed the acid Lewis properties of these catalysts. (c) 2007 Elsevier B.V. All rights reserved.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Modulations in the excitability of spinal reflex pathways during passive rhythmic movements of the lower limb have been demonstrated by a number of previous studies [4]. Less emphasis has been placed on the role of supraspinal pathways during passive movement, and on tasks involving the upper limb. In the present study, transcranial magnetic stimulation (TMS) was delivered to subjects while undergoing passive flexion-extension movements of the contralateral wrist. Motor evoked potentials (MEPs) of flexor carpi radialis (FCR) and abductor pollicus brevis (APB) muscles were recorded. Stimuli were delivered in eight phases of the movement cycle during three different frequencies of movement. Evidence of marked modulations in pathway excitability was found in the MEP amplitudes of the FCR muscle, with responses inhibited and facilitated from static values in the extension and flexion phases, respectively. The results indicated that at higher frequencies of movement there was greater modulation in pathway excitability. Paired-pulse TMS (sub-threshold conditioning) at short interstimulus intervals revealed modulations in the extent of inhibition in MEP amplitude at high movement frequencies. In the APE muscle, there was some evidence of phasic modulations of response amplitude, although the effects were less marked than those observed in FCR. It is speculated that these modulatory effects are mediated via Ia afferent pathways and arise as a consequence of the induced forearm muscle shortening and lengthening. Although the level at which this input influences the corticomotoneuronal pathway is difficult to discern, a contribution from cortical regions is suggested. (C) 2001 Published by Elsevier Science B.V.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

We describe an experimental system designed for single-shot photoelectron spectroscopy on free atoms and molecules at the Free Electron Laser in Hamburg (FLASH at DESY). The combination of the extreme ultra-violet (EUV) Free Electron Laser and a temporally synchronized optical fs laser (Ti:Sapphire) enables a variety of two-color pump-probe experiments. The spectral, temporal and spatial characteristics of both the EUV FEL and the optical laser pulses, the experimental procedure to control their overlap as well as the performance of an electron spectrometer used to obtain single-shot photoelectron spectra are discussed. As an illustration of the capabilities of this set-up, some results on two-photon two-color ionization of rare gases are presented. (c) 2007 Elsevier B.V. All rights reserved.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Metrology of XUV beams (X-ray lasers, high-harmonic generation and VUV free-electron lasers) is of crucial importance for the development of applications. We have thus developed several new optical systems enabling us to measure the optical properties of XUV beams. By use of a Michelson interferometer working as a Fourier-transform spectrometer, the line shapes of different X-ray lasers have been measured with a very high accuracy (Deltalambda/lambdasimilar to10(-6)). Achievement of the first XUV wavefront sensor has enabled us to measure the beam quality of laser-pumped as well as discharge-pumped X-ray lasers. A capillary discharge X-ray laser has demonstrated a very good wavefront allowing us to achieve an intensity as high as 3x10(14) W cm(-2) by focusing with a f=5 cm mirror. The sensor accuracy has been measured using a calibrated spherical wave generated by diffraction. The accuracy has been estimated to be as good as lambda/120 at 13 nm. Commercial developments are underway. At Laboratoire d'Optique Appliquee, we are setting up a new beamline based on high-harmonic generation in order to start the femtosecond, coherent XUV optic .