103 resultados para Microscopic analyses


Relevância:

20.00% 20.00%

Publicador:

Resumo:

In this paper, a novel motion-tracking scheme using scale-invariant features is proposed for automatic cell motility analysis in gray-scale microscopic videos, particularly for the live-cell tracking in low-contrast differential interference contrast (DIC) microscopy. In the proposed approach, scale-invariant feature transform (SIFT) points around live cells in the microscopic image are detected, and a structure locality preservation (SLP) scheme using Laplacian Eigenmap is proposed to track the SIFT feature points along successive frames of low-contrast DIC videos. Experiments on low-contrast DIC microscopic videos of various live-cell lines shows that in comparison with principal component analysis (PCA) based SIFT tracking, the proposed Laplacian-SIFT can significantly reduce the error rate of SIFT feature tracking. With this enhancement, further experimental results demonstrate that the proposed scheme is a robust and accurate approach to tackling the challenge of live-cell tracking in DIC microscopy.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Systematic reviews and meta-analyses are essential to summarize evidence relating to efficacy and safety of health care interventions accurately and reliably. The clarity and transparency of these reports, however, is not optimal. Poor reporting of systematic reviews diminishes their value to clinicians, policy makers, and other users. Since the development of the QUOROM (QUality Of Reporting Of Meta-analysis) Statement-a reporting guideline published in 1999-there have been several conceptual, methodological, and practical advances regarding the conduct and reporting of systematic reviews and meta-analyses. Also, reviews of published systematic reviews have found that key information about these studies is often poorly reported. Realizing these issues, an international group that included experienced authors and methodologists developed PRISMA ( Preferred Reporting Items for Systematic reviews and Meta-Analyses) as an evolution of the original QUOROM guideline for systematic reviews and meta-analyses of evaluations of health care interventions. The PRISMA Statement consists of a 27-item checklist and a four-phase flow diagram. The checklist includes items deemed essential for transparent reporting of a systematic review. In this Explanation and Elaboration document, we explain the meaning and rationale for each checklist item. For each item, we include an example of good reporting and, where possible, references to relevant empirical studies and methodological literature. The PRISMA Statement, this document, and the associated Web site (http://www.prisma-statement.org/) should be helpful resources to improve reporting of systematic reviews and metaanalyses.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Stress analysis of the cement fixation of orthopaedic implants to bone is frequently? carried out using finite element analysis. However, the stress distribution in the cement laver is usually intricate, and it is difficult to report it in a way that facilitates comparison of implants for pre-clinical testing. To study this problem, and make recommendations for stress reporting, a finite element analysis of a hip prosthesis implanted into a synthetic composite femur is developed. Three cases are analyzed: a fully bonded implant, a debonded implant, and a debonded implant where the cement is removed distal to the stein tip. In addition to peak stresses, and contour and vector plots, a stressed volume and probability-of-failure analysis is reported. It is predicted that the peak stress is highest for the debonded stem, and that removal of the distal cement more than halves this peak stress. This would suggest that omission of the distal cement is good for polished prostheses (as practiced for the Exeter design). However; if the percentage of cement stressed above a certain threshold (say 3 MPa) is considered, then the removal of distal cement is shown to be disadvantageous because a higher volume of cement is stressed to above the threshold. Vector plots clearly demonstrate the different load transfer for bonded and debonded prostheses: A bonded stein generates maximum tensile stresses in the longitudinal direction, whereas a debonded stem generates most tensile stresses in the hoop direction, except near the tip where tensile longitudinal stresses occur due to subsidence of the stein. Removal of the cement distal to the tip allows greater subsidence but alleviates these large stresses at the tip, albeit at the expense of increased hoop stresses throughout the mantle. It is concluded that a thorough analysis of cemented implants should not report peak stress, which can be misleading, but rather stressed volume, and that vector plots should be reported if a precise analysis of the load transfer mechanism is required.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

We propose a hybrid approach to the experimental assessment of the genuine quantum features of a general system consisting of microscopic and macroscopic parts. We infer entanglement by combining dichotomic measurements on a bidimensional system and phase-space inference through the Wigner distribution associated with the macroscopic component of the state. As a benchmark, we investigate the feasibility of our proposal in a bipartite-entangled state composed of a single-photon and a multiphoton field. Our analysis shows that, under ideal conditions, maximal violation of a Clauser-Horne-Shimony-Holt-based inequality is achievable regardless of the number of photons in the macroscopic part of the state. The difficulty in observing entanglement when losses and detection inefficiency are included can be overcome by using a hybrid entanglement witness that allows efficient correction for losses in the few-photon regime.

Relevância:

20.00% 20.00%

Publicador:

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Specific antisera, directed against the highly conserved C-terminal hexapeptide amide of mammalian pancreatic polypeptide (PP) and the invertebrate peptide FMRFamide, have been used in conjunction with post-embedding, IgG-conjugated colloidal gold immunostaining to demonstrate peptide immunoreactivity at subcellular level in the nervous system of adult Diclidophora merlangi. Gold labelling revealed that immunoreactivity for PP and FMRFamide was localized exclusively in dense-cored vesicles occupying the majority of axons in the central nervous system. Double-labelling demonstrated an apparent co-localization of PP and FMRFamide in the same dense-cored vesicles. Antigen preabsorption experiments indicated cross-reactivity of the two antisera as unlikely, and that some if not all of the PP/FMRFamide immunostaining in the parasite was due to a neuropeptide F-like peptide.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

1. A neuropeptide exhibiting pancreatic polypeptide-immunoreactivity (PP-IR) has been isolated and characterised from the parasitic platyhelminth, Diclidophora merlangi.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

In a previous paper we have published observational data for 6 early B-type stars having, galactocentric distances of between 10 and 18 kpc. Using LTE line-blanketed model at mosphere techniques we derived their atmospheric parameters, finding that all our targets had similar effective temperatures and surface gravities. In the following study we additionally include two stars which have been presented previously (Rolleston et al. 1993) and found also to have compatible atmospheric parameters to the original programme stars. The homogeneity of this sample allows quantitative line-by-line differential abundance analyses to be carried out which should reliably detect variations in the chemical compositions of the stellar photospheres. We present differential abundances for eight stars, in either young open clusters or the field, with respect to an arbitrarily chosen standard which shows a normal abundance pattern. Our method of calculating distances from the derived atmospheric parameters means that the relative distance scale should be accurate.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

High resolution spectra of six early B-type main-sequence stars having galactocentric distances of between 10 and 18 kpc are presented. We List the equivalent widths for the metal lines and illustrate their hydrogen and helium line profiles. The stars are analysed using LTE line-blanketed model atmosphere techniques to derive atmospheric parameters and surface chemical compositions. All six stars have similar effective temperatures and surface gravities, allowing a reliable comparison of their metal abundances and distances. Significant variations in the photospheric abundances are evident and are discuss the need for a more detailed line-by-line differential analysis to exactly quantify the differences. This will be presented in a companion paper (Smartt et al. 1996).