53 resultados para Method development and research


Relevância:

100.00% 100.00%

Publicador:

Resumo:

In this study the design and development of two real-time PCR assays for the rapid, sensitive and specific detection of infectious laryngotracheitis virus (ILTV) DNA is described. A Primer-Probe Energy Transfer (PriProET) assay and 5' conjugated Minor Groove Binder (MGB) method are compared and contrasted. Both have been designed to target the thymidine kinase gene of the ILTV genome. Both PriProET and MGB assays are capable of detecting 20 copies of a DNA standard per reaction and are linear from 2 x 10(8) to 2 x 10(2) copies/mu l. Neither PriProET, nor MGB reacted with heterologous herpesviruses, indicating a high specificity of the two methods as novel tools for virus detection and identification. This study demonstrates the suitability of PriProET and 5' conjugated MGB probes as real-time PCR chemistries for the diagnosis of respiratory diseases caused by ILTV. (C) 2011 Elsevier B.V. All rights reserved.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

The paper describes the development and application of a multiple linear regression model to identify how the key elements of waste and recycling infrastructure, namely container capacity and frequency of collection affect the yield from municipal kerbside recycling programmes. The overall aim of the research was to gain an understanding of the factors affecting the yield from municipal kerbside recycling programmes in Scotland. The study isolates the principal kerbside collection service offered by 32 councils across Scotland, eliminating those recycling programmes associated with flatted properties or multi occupancies. The results of a regression analysis model has identified three principal factors which explain 80% of the variability in the average yield of the principal dry recyclate services: weekly residual waste capacity, number of materials collected and the weekly recycling capacity. The use of the model has been evaluated and recommendations made on ongoing methodological development and the use of the results in informing the design of kerbside recycling programmes. The authors hope that the research can provide insights for the ongoing development of methods to optimise the design and operation of kerbside recycling programmes.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

In the Public Health White Paper "Healthy Lives, Healthy People" (2010), the UK Government emphasised using incentives and "nudging" to encourage positive, healthy behaviour changes. However, there is little evidence that nudging is effective, in particular for increasing physical activity. We have created a platform to research the effectiveness of health-related behaviour change interventions and incentive schemes. The system consists of an outward-facing website, incorporating tools for incentivizing behaviour change, and a novel physical activity monitoring system. The monitoring system consists of the "Physical Activity Loyalty Card", which contains a passive RFID tag, and a contactless sensor network to detect the cards. This paper describes the application of this novel web-based system to investigate the effectiveness of non-cash incentives to "nudge" adults to undertake more physical activity. © 2012 ICST Institute for Computer Science, Social Informatics and Telecommunications Engineering.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Primary care in the United States is undergoing many changes. Reliable and valid instruments are needed to assess the effects of these changes. The Primary Care Organizational Questionnaire (PCOQ), a 56-item 5-point Likert scale survey that evaluates interactions among members of the clinic/practice and job-related attributes, was administered to clinicians and staff in 36 primary care practices serving paediatric populations in Connecticut. A priori scales were reliable (Cronbach alpha =0.7). Analysis of variance (ANOVA) showed greater heterogeneity across clinics than within clinics for 13 of 15 a priori scales, which were then included in a principal component factor analysis with varimax rotation. Eigenvalue analysis showed nine significant factors, largely similar to the a priori scales, indicating concurrent construct validity. Further research will ascertain the utility of the PCOQ in predicting the effectiveness of primary care practices in implementing disease management programmes. © 2006 Royal Society of Medicine Press.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Cronobacter (formerly known as Enterobacter sakazakii) is a genus comprising seven species regarded as opportunistic pathogens that can be found in a wide variety of environments and foods, including powdered infant formula (PIF). Cronobacter sakazakii, the major species of this genus, has been epidemiologically linked to cases of bacteremia, meningitis in neonates, and necrotizing enterocolitis, and contaminated PIF has been identified as an important source of infection. Robust and reproducible subtyping methods are required to aid in the detection and investigation, of foodborne outbreaks. In this study, a pulsed-field gel electrophoresis (PFGE) protocol was developed and validated for subtyping Cronobacter species. It was derived from an existing modified PulseNet protocol, wherein XbaI and SpeI were the primary and secondary restriction enzymes used, generating an average of 14.7 and 20.3 bands, respectively. The PFGE method developed was both reproducible and discriminatory for subtyping Cronobacter species.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Background: Potentially inappropriate prescribing (PIP) in older people is common in primary care and can result in increased morbidity, adverse drug events, hospitalizations and mortality. The prevalence of PIP in Ireland is estimated at 36% with an associated expenditure of over [euro sign]45 million in 2007. The aim of this paper is to describe the application of the Medical Research Council (MRC) framework to the development of an intervention to decrease PIP in Irish primary care.

Methods: The MRC framework for the design and evaluation of complex interventions guided the development of the study intervention. In the development stage, literature was reviewed and combined with information obtained from experts in the field using a consensus based methodology and patient cases to define the main components of the intervention. In the pilot stage, five GPs tested the proposed intervention. Qualitative interviews were conducted with the GPs to inform the development and implementation of the intervention for the main randomised controlled trial.

Results: The literature review identified PIP criteria for inclusion in the study and two initial intervention components - academic detailing and medicines review supported by therapeutic treatment algorithms. Through patient case studies and a focus group with a group of 8 GPs, these components were refined and a third component of the intervention identified - patient information leaflets. The intervention was tested in a pilot study. In total, eight medicine reviews were conducted across five GP practices. These reviews addressed ten instances of PIP, nine of which were addressed in the form of either a dose reduction or a discontinuation of a targeted medication. Qualitative interviews highlighted that GPs were receptive to the intervention but patient preference and time needed both to prepare for and conduct the medicines review, emerged as potential barriers. Findings from the pilot study allowed further refinement to produce the finalised intervention of academic detailing with a pharmacist, medicines review with web-based therapeutic treatment algorithms and tailored patient information leaflets.

Conclusions: The MRC framework was used in the development of the OPTI-SCRIPT intervention to decrease the level of PIP in primary care in Ireland. Its application ensured that the intervention was developed using the best available evidence, was acceptable to GPs and feasible to deliver in the clinical setting. The effectiveness of this intervention is currently being tested in a pragmatic cluster randomised controlled trial.

Trial registration: Current controlled trials ISRCTN41694007.© 2013 Clyne et al.; licensee BioMed Central Ltd.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Tetrodotoxin (TTX) is a potent neurotoxin emerging in European waters due to increasing ocean temperatures. Its detection in seafood is currently performed as a consequence of using the Association of Analytical Communities (AOAC) mouse bioassay (MBA) for paralytic shellfish poisoning (PSP) toxins, but TTX is not monitored routinely in Europe. Due to ethical and performance-related issues associated with this bioassay, the European Commission has recently published directives extending procedures that may be used for official PSP control. An AOAC-accredited high-performance liquid chromatography (HPLC) method has now been accepted by the European Union as a first action screening method for PSP toxins to replace the MBA. However, this AOAC HPLC method is not capable of detecting TTX, so this potent toxin would be undetected; thereby, a separate method of analysis is required. Surface plasmon resonance (SPR) optical biosensor technology has been proven as a potential alternative screening method to detect PSP toxins in seafood. The addition of a similar SPR inhibition assay for TTX would complement the PSP assay in removing the MBA. The present report describes the development and single laboratory validation in accordance with AOAC and IUPAC guidelines of an SPR method to be used as a rapid screening tool to detect TTX in the sea snail Charonia lampas lampas, a species which has been implicated in 2008 in the first case of human TTX poisoning in Europe. As no current regulatory limits are set for TTX in Europe, single laboratory validation was undertaken using those for PSP toxins at 800 µg/kg. The decision limit (CCa) was 100 µg/kg, with the detection capability (CCß) found to be =200 µg/kg. Repeatability and reproducibility were assessed at 200, 400, and 800 µg/kg and showed relative standard deviations of 8.3, 3.8, and 5.4 % and 7.8, 8.3, and 3.7 % for both parameters at each level, respectively. At these three respective levels, the recovery of the assay was 112, 98, and 99 %.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

A lateral flow immunoassay (LFIA) has been developed and fully validated to detect the primary amnesic shellfish poisoning (ASP) toxin, domoic acid (DA). The performance characteristics of two versions of the test were investigated using spiked and naturally contaminated shellfish (mussels, scallops, oysters, clams, and cockles). The tests provide a qualitative result, to indicate the absence or presence of DA in extracts of shellfish tissues, at concentrations that are relevant to regulatory limits. The new rapid assay (LFIA version 2) was designed to overcome the performance limitations identified in the first version of the assay. The improved test uses an electronic reader to remove the subjective nature of the generated results, and the positive cut-off for screening of DA in shellfish was increased from 10 ppm (version 1) to 17.5 ppm (version 2). A simple extraction and test procedure was employed, which required minimal equipment and materials; results were available 15 min after sample preparation. Stability of the aqueous extracts at room temperature (22 C) at four time points (up to 245 min after extraction) and across a range of DA concentrations was 100.3±1.3% and 98.8±2.4% for pre- and post-buffered extracts, respectively. The assay can be used both within laboratory settings and in remote locations. The accuracy of the new assay, to indicate negative results at or below 10 ppm DA, and positive results at or above 17.5 ppm, was 99.5% (n=216 tests). Validation data were obtained from a 2-day, randomised, blind study consisting of multiple LFIA lots (n=3), readers (n=3) and operators (n=3), carrying out multiple extractions of mussel tissue (n=3) at each concentration (0, 10, 17.5, and 20 ppm). No matrix effects were observed on the performance of the assay with different species (mussels, scallops, oysters, clams, and cockles). There was no impact on accuracy or interference from other phycotoxins, glutamic acid or glutamine with various strip incubations (8, 10, and 12 min). The accuracy of the assay, using naturally contaminated samples to indicate negative results at or below 12.5 ppm and positive results at or above 17.5 ppm, was 100%. Variability between three LFIA lots across a range of DA concentrations, expressed as coefficient of variation (% CV), was 1.1±0.4% (n=2 days) based on quantitative readings from the electronic reader. During an 8 week stability study, accuracy of the method with test strips stored at various temperatures (6, 22, 37 and 50 C) was 100%. Validation for both versions included comparisons with results obtained using reference LC-UV methods. © 2013 Elsevier B.V.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

As increasing incidences in the occurrence of cylindrospermopsin (CYN) appear, in addition to further research on its toxicological nature, improved rapid methods to detect this toxin are required. Antibody based assays are renowned for their ability to provide rapid, portable, simple to use tests. As yet however there are no publications outlining how an antibody to CYN can be produced. A range of chemical approaches was investigated to synthesise CYN immunogens for antibody production but failed to generate a response. Finally, a modified Mannich reaction for immunogen synthesis was employed to couple the toxin to two carrier proteins. Both protein conjugates were successfully used to raise both polyclonal and monoclonal antibodies of high sensitivity to CYN. These antibodies were characterised employing competitive indirect ELISA and an optical biosensor assay. By ELISA the sensitivity achieved ranged from 27 to 131. pg/mL and by SPR 4.4 to 11.1. ng/mL thus demonstrating that the selection of immunoassay platform is important for the detection level required by the end user for their application. Low cross-reactivity to the much less toxic metabolite deoxyCYN was observed. This is the first reported production of antibodies to this toxin. © 2013 Elsevier B.V.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Pyrrolizidine alkaloids (PAs) are a group of plant secondary metabolites with carcinogenic and hepatotoxic properties. When PA-producing plants contaminate crops, toxins can be transferred through the food chain and cause illness in humans and animals, most notably hepatic veno-occlusive disease. Honey has been identified as a direct risk of human exposure. The European Food Safety Authority has recently identified four groups of PAs that are of particular importance for food and feed: senecionine-type, lycopsamine-type, heliotrine-type and monocrotaline-type. Liquid or gas chromatography methods are currently used to detect PAs but there are no rapid screening assays available commercially. Therefore, the aim of this study was to develop a rapid multiplex ELISA test for the representatives of three groups of alkaloids (senecionine, lycopsamine and heliotrine types) that would be used as a risk-management tool for the screening of these toxic compounds in food and feed. The method was validated for honey and feed matrices and was demonstrated to have a detection capability less than 25 µg/kg for jacobine, lycopsamine, heliotrine and senecionine. The zinc reduction step introduced to the extraction procedure allows for the additional detection of the presence of N-oxides of PAs. This first multiplex immunoassay for PA detection with N-oxide reduction can be used for the simultaneous screening of 21 samples for >12 PA analytes. Honey samples (n?=?146) from various origins were analysed for PA determination. Six samples were determined to contain measurable PAs >25 µg/kg by ELISA which correlated to >10 µg/kg by LC-MS/MS.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

This paper reports image analysis methods that have been developed to study the microstructural changes of non-wovens made by the hydroentanglement process. The validity of the image processing techniques has been ascertained by applying them to test images with known properties. The parameters in preprocessing of the scanning electron microscope (SEM) images used in image processing have been tested and optimized. The fibre orientation distribution is estimated using fast Fourier transform (FFT) and Hough transform (HT) methods. The results obtained using these two methods are in good agreement. The HT method is more demanding in computational time compared with the Fourier transform (FT) method. However, the advantage of the HT method is that the actual orientation of the lines can be concluded directly from the result of the transform without the need for any further computation. The distribution of the length of the straight fibre segments of the fabrics is evaluated by the HT method. The effect of curl of the fibres on the result of this evaluation is shown.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Eye-tracking studies have shown how people with autism spend significantly less time looking at socially relevant information on-screen compared to those developing typically. This has been suggested to impact on the development of socio-cognitive skills in autism. We present novel evidence of how attention atypicalities in children with autism extend to real-life interaction, in comparison to typically developing (TD) children and children with specific language impairment (SLI). We explored the allocation of attention during social interaction with an interlocutor, and how aspects of attention (awareness checking) related to traditional measures of social cognition (false belief attribution). We found divergent attention allocation patterns across the groups in relation to social cognition ability. Even though children with autism and SLI performed similarly on the socio- cognitive tasks, there were syndrome-specific atypicalities of their attention patterns. Children with SLI were most similar to TD children in terms of prioritising attention to socially pertinent information (eyes, face, awareness checking). Children with autism showed reduced attention to the eyes and face, and slower awareness checking. This study provides unique and timely insight into real-world social gaze (a)typicality in autism, SLI and typical development, its relationship to socio-cognitive ability, and raises important issues for intervention.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Background: The palliative care clinical nurse specialist (PC-CNS) is a core member of the specialist palliative care team. According to professional policy, the role has four specific components: clinical practice, education, research, and leadership and management. Little is known about how to support staff in this role. Aim: The aim of this study was to explore what learning, development, and support PC-CNSs in one hospice need to enable them to fulfil all components of their role. Design: Using a descriptive exploratory approach, semi-structured interviews were undertaken with a purposive sample of community PC-CNSs from a hospice in Northern Ireland. Interviews were audio-recorded, transcribed verbatim, and thematically analysed. Findings: Seventeen interviews were analysed and three themes identified: influence of organisational culture, influence of the individual, and learning and development solutions. Conclusions: Participants reported that the PC-CNS role was stressful. They identified that the organisational culture and indeed individuals themselves influenced the learning and development support available to help them fulfil the four components of the role. Working relationships and stability within teams affected how supported individuals felt and had implications for managers in meeting the needs of staff while balancing the needs of the service.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

The term fatigue loads on the Oyster Oscillating Wave Surge Converter (OWSC) is used to describe hydrostatic loads due to water surface elevation with quasi-static changes of state. Therefore a procedure to implement hydrostatic pressure distributions into finite element analysis of the structure is desired. Currently available experimental methods enable one to measure time variant water surface elevation at discrete locations either on or around the body of the scale model during tank tests. This paper discusses the development of a finite element analysis procedure to implement time variant, spatially distributed hydrostatic pressure derived from discretely measured water surface elevation. The developed method can process differently resolved (temporal and spatial) input data and approximate the elevation over the flap faces with user defined properties. The structural loads, namely the forces and moments on the body can then be investigated by post processing the numerical results. This method offers the possibility to process surface elevation or hydrostatic pressure data from computational fluid dynamics simulations and can thus be seen as a first step to a fluid-structure interaction model.