146 resultados para McKinnon Columbus Chain Limited
Resumo:
Density functional calculations, using B3LPY/6-31G(d) methods, have been used to investigate the conformations and vibrational (Raman) spectra of a series of long-chain, saturated fatty acid methyl esters (FAMEs) with the formula CH2nO2 (n = 5-21) and two series of unsaturated FAMEs. The calculations showed that the lowest energy conformer within the saturated FAMEs is the simple (all-trans) structure and, in general, it was possible to reproduce experimental data using calculations on only the all-trans conformer. The only exception was C6H12O2, where a second low-lying conformer had to be included in order to correctly simulate the experimental Raman spectrum. The objective of the work was to provide theoretical justification for the methods that are commonly used to determine the properties of the fats and oils, such as chain length and degree of unsaturation, from experimental Raman data. Here it is shown that the calculations reproduce the trends and calibration curves that are found experimentally and also allow the reasons for the failure of what would appear to be rational measurements to be understood. This work shows that although the assumption that each FAME can simply be treated as a collection of functional groups can be justified in some cases, many of the vibrational modes are complex motions of large sections of the molecules and thus would not be expected to show simple linear trends with changes in structure, such as increasing chain length and/or unsaturation. Simple linear trends obtained from experimental data may thus arise from cancellation of opposing effects, rather than reflecting an underlying simplicity.
Resumo:
Density functional calculations, using B3LPY/6-31G(d) methods, have been used to investigate the conformations and vibrational (Raman) spectra of three short-chain fatty acid methyl esters (FAMEs) with the formula CnH2nO2 (n = 3-5). In all three FAMEs, the lowest energy conformer has a simple 'all-trans' structure but there are other conformers, with different torsions about the backbone, which lie reasonably close in energy to the global minimum. One result of this is that the solid samples we studied do not appear to consist entirely of the lowest energy conformer. Indeed, to account for the 'extra' bands that were observed in the Raman data but were not predicted for the all-trans conformer, it was necessary to add-in contributions from other conformers before a complete set of vibrational assignments could be made. Provided this was done, the agreement between experimental Raman frequencies and 6-31G(d) values (after scaling) was excellent, RSD = 12.6 cm(-1). However, the agreement between predicted and observed intensities was much less satisfactory. To confirm the validity of the approach followed by the 6-3 1 G(d) basis set, we used a larger basis set, Sadlej pVTZ, and found that these calculations gave accurate Raman intensities and simulated spectra (summed from two different conformers) that were in quantitative agreement with experiment. In addition, the unscaled Sadlej pVTZ, and the scaled 6-3 1 G(d) calculations gave the same vibrational mode assignments for all bands in the experimental data. This work provides the foundation for calculations on longer-chain FAMEs (which are closer to those found as triglycerides in edible fats and oils) because it shows that scaled 6-3 1 G(d) calculations give equally accurate frequency predictions, and the same vibrational mode assignments, as the much more CPU-expensive Sadlej pVTZ basis set calculations.
Resumo:
We describe a malignant lymphoma of the parotid gland arising in a patient with Sjögren's syndrome. Diagnosis was established on needle biopsy which showed a mixed population of lymphoid cells. Immunohistochemistry revealed B-lymphoid cells, T-lymphoid cells and histiocytes. Clonal immunoglobulin heavy chain gene rearrangement was demonstrated using the polymerase chain reaction. Within the confines of the small biopsy, the lesion qualifies for the designation T-cell-rich histiocyte-rich B-cell lymphoma. The value of molecular techniques in the diagnosis of malignant lymphoma on limited tissue samples is highlighted by this case.
Resumo:
Background. Invasive Candida infection among nonneutropenic, critically ill adults is a clinical problem that has received increasing attention in recent years. Poor performance of extant diagnostic modalities has promoted risk-based, preemptive prescribing in view of the poor outcomes associated with inadequate or delayed antifungal therapy; this risks unnecessary overtreatment. A rapid, reliable diagnostic test could have a substantial impact on therapeutic practice in this patient population.
Methods. Three TaqMan-based real-time polymerase chain reaction assays were developed that are capable of detecting the main medically important Candida species, categorized according to the likelihood of fluconazole susceptibility. Assay 1 detected Candida albicans, Candida parapsilosis, Candida tropicalis, and Candida dubliniensis. Assays 2 and 3 detected Candida glabrata and Candida krusei, respectively. The clinical performance of these assays, applied to serum, was evaluated in a prospective trial of nonneutropenic adults in a single intensive care unit.
Results. In all, 527 specimens were obtained from 157 participants. All 3 assays were run in parallel for each specimen; they could be completed within 1 working day. Of these, 23 specimens were obtained from 23 participants categorized as having proven Candida infection at the time of sampling. If a single episode of Candida famata candidemia was excluded, the estimated clinical sensitivity, specificity, and positive and negative predictive values of the assays in this trial were 90.9%, 100%, 100% and 99.8%, respectively.
Conclusions. These data suggest that the described assays perform well in this population for enhancing the diagnosis of candidemia. The extent to which they may affect clinical outcomes, prescribing practice, and cost-effectiveness of care remains to be ascertained.
Resumo:
Micro plasmas operated at ambient pressure with dimensions of the confining geometry in the order of a few ten micrometers to a millimeter are actually in the focus of interest due to the broad regime of applicability they offer and due to a similarly broad range of open physical questions. Here we present optical measurements within the discharge core and the effluent region of an especially developed micro discharge jet. To get an understanding of the complex system of this discharge it is important to analyse transport phenomena of energy and particles within both parts of the discharge by various highly sophisticated diagnostics. As a consequence of the limited access and the dimensions of the micro discharge most of these diagnostics are optical. Here we present diagnostics applied to determine spatially resolved absolute atomic oxygen densities as the most reactive constituent of the effluent, density maps of ozone as final reaction product of the gas chemical chain induced by the discharge and phase resolved optical emission spectroscopy yielding insight into the excitation dynamics of the discharge. (C) 2007 WILEY-VCH Verlag GmbH & Co. KGaA. Weinheim.