60 resultados para Low-grade heat


Relevância:

40.00% 40.00%

Publicador:

Resumo:

Epithelial ovarian cancer (EOC) has an innate susceptibility to become chemoresistant. Up to 30% of patients do not respond to conventional chemotherapy [paclitaxel (Taxol®) in combination with carboplatin] and, of those who have an initial response, many patients relapse. Therefore, an understanding of the molecular mechanisms that regulate cellular chemotherapeutic responses in EOC cells has the potential to impact significantly on patient outcome. The mitotic arrest deficiency protein 2 (MAD2), is a centrally important mediator of the cellular response to paclitaxel. MAD2 immunohistochemical analysis was performed on 82 high-grade serous EOC samples. A multivariate Cox regression analysis of nuclear MAD2 IHC intensity adjusting for stage, tumour grade and optimum surgical debulking revealed that low MAD2 IHC staining intensity was significantly associated with reduced progression-free survival (PFS) (p = 0.0003), with a hazard ratio of 4.689. The in vitro analyses of five ovarian cancer cell lines demonstrated that cells with low MAD2 expression were less sensitive to paclitaxel. Furthermore, paclitaxel-induced activation of the spindle assembly checkpoint (SAC) and apoptotic cell death was abrogated in cells transfected with MAD2 siRNA. In silico analysis identified a miR-433 binding domain in the MAD2 3' UTR, which was verified in a series of experiments. Firstly, MAD2 protein expression levels were down-regulated in pre-miR-433 transfected A2780 cells. Secondly, pre-miR-433 suppressed the activity of a reporter construct containing the 3'-UTR of MAD2. Thirdly, blocking miR-433 binding to the MAD2 3' UTR protected MAD2 from miR-433 induced protein down-regulation. Importantly, reduced MAD2 protein expression in pre-miR-433-transfected A2780 cells rendered these cells less sensitive to paclitaxel. In conclusion, loss of MAD2 protein expression results in increased resistance to paclitaxel in EOC cells. Measuring MAD2 IHC staining intensity may predict paclitaxel responses in women presenting with high-grade serous EOC.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

The object of this work is to assess the suitability of metallocene catalyzed linear low-density polyethylenes for the rotational molding of foams and to link the material and processing conditions to cell morphology and part mechanical properties (flexural and compressive strength). Through adjustments to molding conditions, the significant processing and physical material parameters that optimize metallocene catalyzed linear low-density polyethylene foam structure have been identified. The results obtained from an equivalent conventional grade of Ziegler-Natta catalyzed linear low-density polyethylene are used as a basis for comparison. The key findings of this study are that metallocene catalyzed LLDPE can be used in rotational foam molding to produce a foam that will perform as well as a ZieglerNatta catalyzed foam and that foam density Is by far the most Influential factor over mechanical properties of foam. © 2004 Society of Plastics Engineers.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

The significantly higher surface expression of the surface heat-shock protein receptor CD91 on monocytes of human immunodeficiency virus type-1 (HIV-1)-infected, long-term nonprogressors suggests that HIV-1 antigen uptake and cross-presentation mediated by CD91 may contribute to host anti-HIV-1 defenses and play a role in protection against HIV-1 infection. To investigate this further, we performed phenotypic analysis to compare CD91 surface expression on CD14+ monocytes derived from a cohort of HIV-1-exposed seronegative (ESN) subjects, their seropositive (SP) partners, and healthy HIV-1-unexposed seronegative (USN) subjects. The median fluorescent intensity (MFI) of CD91 on CD14+ monocytes was significantly higher in ESN compared with SP (P=0.028) or USN (P=0.007), as well as in SP compared with USN subjects (P=0.018). CD91 MFI was not normalized in SP subjects on highly active antiretroviral therapy (HAART) despite sustainable, undetectable plasma viraemia. Data in three SP subjects experiencing viral rebounds following interruption of HAART showed low CD91 MFI comparable with levels in USN subjects. There was a significant positive correlation between CD91 MFI and CD8+ T cell counts in HAART-naïve SP subjects (r=0.7, P=0.015). Increased surface expression of CD91 on CD14+ monocytes is associated with the apparent HIV-1 resistance that is observed in ESN subjects.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Ionic liquids are organic salts with low melting points. Many of these compounds are liquid at room temperature in their pure state. Since they have negligible vapor pressure and would not contribute to air pollution, they are being intensively investigated for a variety of applications, including as solvents for reactions and separations, as non-volatile electrolytes, and as heat transfer fluids. We present melting temperatures, glass transition temperatures, decomposition temperatures, heat capacities, and viscosities for a large series of pyridinium-based ionic liquids. For comparison, we include data for several imidazolium and quaternary ammonium salts. Many of the compounds do not crystallize, but form glasses at temperatures between 188 K and 223 K. The thermal stability is largely determined by the coordinating ability of the anion, with ionic liquids made with the least coordinating anions, like bis(trifluoromethylsulfonyl)imide, having the best thermal stability. In particular, dimethylaminopyridinium bis(trifluoromethylsulfonyl)imide salts have some of the best thermal stabilities of any ionic liquid compounds investigated to date. Heat capacities increase approximately linearly with increasing molar mass, which corresponds with increasing numbers of translational, vibrational, and rotational modes. Viscosities generally increase with increasing number and length of alkyl substituents on the cation, with the pyridinium salts typically being slightly more viscous than the equivalent imidazolium compounds. (c) 2005 Elsevier Ltd. All rights reserved.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Silicone elastomer systems have been shown to offer potential for the fabrication of medical devices and sustained release drug delivery devices comprising low molecular weight drugs and protein therapeutics. For drug delivery systems in particular, there is often no clear rationale for selection of the silicone elastomer grade, particularly in respect of optimizing the manufacturing conditions to ensure thermal stability of the active agent and short cycle times. In this study, the cure characteristics of a range of addition-cure and condensation-cure, low-consistency, implant-grade silicone elastomers, either as supplied or loaded with the model protein bovine serum albumin (BSA) and the model hydrophilic excipient glycine, were investigated using oscillatory rheology with a view to better understanding the isothermal cure characteristics. The results demonstrate the influence of elastomer type, cure temperature, protein loading, and glycine loading on isothermal cure properties. By measuring the cure time required to achieve tan delta values representative of early and late-stage cure conditions, a ratio t(1)/t(2) was defined that allowed the cure characteristics of the various systems to be compared. Sustained in vitro release of BSA from glycine-loaded silicone elastomer covered rod devices was also demonstrated over 14 days. (C) 2010 Wiley Periodicals, Inc. J Appl Polym Sci 116: 2320-2327, 2010

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Barrett's esophagus is a well-recognized precursor of esophageal adenocarcinoma. Surveillance of Barrett's esophagus patients is recommended to detect high-grade dysplasia (HGD) or early cancer. Because of wide variation in the published cancer incidence in Barrett's esophagus, the authors undertook a systematic review and meta-analysis of cancer and HGD incidence in Barrett's esophagus. Ovid Medline (Ovid Technologies, Inc., New York, New York) and EMBASE (Elsevier, Amsterdam, the Netherlands) databases were searched for papers published between 1950 and 2006 that reported the cancer/HGD risk in Barrett's esophagus. Where possible, early incident cancers/HGD were excluded, as were patients with HGD at baseline. Forty-seven studies were included in the main analysis, and the pooled estimate for cancer incidence in Barrett's esophagus was 6.1/1,000 person-years, 5.3/1,000 person-years when early incident cancers were excluded, and 4.1/1,000 person-years when both early incident cancer and HGD at baseline were excluded. Corresponding figures for combined HGD/cancer incidence were 10.0 person-years, 9.3 person-years, and 9.1/1,000 person-years. Compared with women, men progressed to cancer at twice the rate. Cancer or HGD/cancer incidences were lower when only high-quality studies were analyzed (3.9/1,000 person-years and 7.7/1,000 person-years, respectively). The pooled estimates of cancer and HGD incidence were low, suggesting that the cost-effectiveness of surveillance is questionable unless it can be targeted to those with the highest cancer risk.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

A maraging steel with a composition of Fe–12·94Ni–1·61Al–1·01Mo–0·23Nb (wt-%) was investigated. Optical, scanning electron and transmission electron microscopy and X-ray diffraction analysis were employed to study the microstructure of the steel after different aging periods at temperatures of 450–600°C. Hardness and Charpy impact toughness of the steel were measured. The study of microstructure and mechanical properties showed that nanosized precipitates were formed homogeneously during the aging process, which resulted in high hardness. As the aging time is prolonged, precipitates grow and hardness increases. Fractography of the as forged steel has shown mixed ductile and brittle fracture and has indicated that the steel has good toughness. Relationships among heat treatment, microstructure and mechanical properties are discussed. Further experiments using tensile testing and impact testing for aged steel were carried out.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Joule heat-induced hot-spot formation sets severe limits in the operation of continuous annular electrochromatography (CAEC), a new concept for preparative separation as an analog to analytical capillary electrochromatography (CEC). This may lead to eluent flow perturbance, even to boiling, which would massively weaken separation efficiency and may even hamper the stationary phase used for separation. For reasons of system integration and high-efficiency heat transfer, micro flow heat exchangers are considered with a separate coolant flow. A 3D numerical analysis of the heat transfer of water single-phase laminar flow in a square microchannel and different arrays of micro pin-fins was carried out using COMSOL Multiphysics. Several advanced materials with low electric conductivity and at the same time with high heat conductivity were put forward to be used in the CAEC system. As essential design point, it is proposed to constitute the micro heat exchanger from two different parts of the CAEC system, namely a microstructured pin-fins plate and a so-called conductive plate.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Austenitization with lower temperature and intercritical annealing were introduced in the treatment of a maraging steel with a composition of Fe–12.94Ni–1.61Al–1.01Mo–0.23Nb (wt.%). Scanning electron microscopy was employed to study the microstructure after austenitization at 950 °C and intercritical annealing, followed by aging at 485 and 600 °C. X-ray diffraction (XRD) analysis was applied to evaluate the formation of retained or reverted austenite. Thermodynamic calculation was employed to calculate equilibrium phase mole fractions. Hardness and Charpy impact toughness of the steel were measured. Intercritical annealing treatments did not result in significant increase of hardness either before or after aging. The Charpy impact toughness of the alloy in aged condition was enhanced after austenitization at 950 °C. No austenite was observed in XRD. However, suspected reverted austenite was found after austenitization at 950 °C followed by aging at 600 °C for 4 h. Relationships among heat treatment, microstructure and mechanical properties are discussed.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Most patients with acute myeloid leukaemia (AML) are older, with many unsuitable for conventional chemotherapy. Low-dose Ara-C (LDAC) is superior to best supportive care but is still inadequate. The combination of arsenic trioxide (ATO) and LDAC showed promise in an unrandomised study. We report a randomised trial of LDAC versus LDAC + ATO. Patients with AML according to WHO criteria or myelodysplastic syndrome with > 10% blasts, considered as unfit for conventional chemotherapy, were randomised between subcutaneous Ara-C (20mg b.d. for 10 days) and the same LDAC schedule with ATO (0.25 mg/kg) on days 1-5, 9 and 11, for at least four courses every 4 to 6 weeks. Overall 166 patients were entered; the trial was terminated on the advice of the DMC, as the projected benefit was not observed. Overall 14% of patients achieved complete remission (CR) and 7% CRi. Median survival was 5.5 months and 19 months for responders (CR: not reached; CRi: 14 months; non-responders: 4 months). There were no differences in response or survival between the arms. Grade 3/4 cardiac and liver toxicity, and supportive care requirements were greater in the ATO arm. This randomised comparison demonstrates that adding ATO to LDAC provides no benefit for older patients with AML. Leukemia (2011) 25, 1122-1127; doi:10.1038/leu.2011.59; published online 8 April 2011

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Chlorination of wheat flour in the EU countries has been replaced in recent years, to some extent, by heat treated flour which is used to produce high ratio cakes. Heat treated flour allows high ratio recipes to be developed which generate products with longer shelf life, finer texture, moist crumb and sweeter taste. The mechanism by which heat treatment improves the flour is not fully understood, but it is known that during the heat treatment process, protein denaturation and partial gelatinisation of the starch granules occurs, as well as an increase in batter viscosity. Therefore, it is important to optimize the flour heat treatment process, in order to enhance baking quality. Laboratory preparation of heat treated base wheat flour (culinary, soft, low protein) was carried out in a fluidised bed drier using a range of temperatures and times. The gluten was extracted from the final product and its quality was tested, to obtain objective and comparative information on the extent of protein denaturation. The results indicated that heat treatment of flour decreases gluten extensibility and partial gelatinisation of the starch granules occurred. After heat treatment the gluten appeared to retain moisture. The optimum time/temperature for the heat treatment of base flour was 120-130°C for 30 min with moisture content of ˜12.5%.© 2012 Elsevier Ltd. All rights reserved.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

One of the most critical gas turbine engine components, the rotor blade tip and casing, is exposed to high thermal load. It becomes a significant design challenge to protect the turbine materials from this severe situation. The purpose of this paper is to study numerically the effect of turbine inlet temperature on the tip leakage flow structure and heat transfer. In this paper, the effect of turbine inlet temperature on the tip leakage flow structure and heat transfer has been studied numerically. Uniform low (LTIT: 444 K) and high (HTIT: 800 K) turbine inlet temperature, as well as non-uniform inlet temperature have been considered. The results showed the higher turbine inlet temperature yields the higher velocity and temperature variations in the leakage flow aerodynamics and heat transfer. For a given turbine geometry and on-design operating conditions, the turbine power output can be increased by 1.33 times, when the turbine inlet temperature increases 1.80 times. Whereas the averaged heat fluxes on the casing and the blade tip become 2.71 and 2.82 times larger, respectively. Therefore, about 2.8 times larger cooling capacity is required to keep the same turbine material temperature. Furthermore, the maximum heat flux on the blade tip of high turbine inlet temperature case reaches up to 3.348 times larger than that of LTIT case. The effect of the interaction of stator and rotor on heat transfer features is also explored using unsteady simulations. The non-uniform turbine inlet temperature enhances the heat flux fluctuation on the blade tip and casing.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

High thermal load appears at the blade tip and casing of a gas turbine engine. It becomes a significant design challenge to protect the turbine materials from this severe situation. As a result of geometric complexity and experimental limitations, computational fluid dynamics tools have been used to predict blade tip leakage flow aerodynamics and heat transfer at typical engine operating conditions. In this paper, the effect of turbine inlet temperature on the tip leakage flow structure and heat transfer has been studied numerically. Uniform low (444 K) and high (800 K) inlet temperatures and nonuniform (parabolic) temperature profiles have been considered at a fixed rotor rotation speed (9500 rpm). The results showed that the change of flow properties at a higher inlet temperature yields significant variations in the leakage flow aerodynamics and heat transfer relative to the lower inlet temperature condition. Aerodynamic behavior of the tip leakage flow varies significantly with the distortion of turbine inlet temperature. For more realistic inlet condition, the velocity range is insignificant at all the time instants. At a high inlet temperature, reverse secondary flow is strongly opposed by the tip leakage flow and the heat transfer fluctuations are reduced greatly.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

In a prospective study of 501 infants of low birth weight (LBW) who mostly weighed 2,041 g (4 1/2 lb) or less, and of 203 control infants of full birth weight (FBW > 2,500 g), 335 LBW and 139 FBW children were followed beyond the age of 6 years and 6 months. The incidence of neurological defects was negatively correlated with birth weight, and the mean "global" IQ of different birth weight groups retained a direct relationship. While the relationship of birth weight to IQ gradually became less marked, the effect of social class was increasingly evident from the age of 2 years and 6 months. The preterm children whose birth weight was appropriate for gestational age (AGA) attained a slightly higher mean IQ and significantly better grade placement in the third school year than the children who were unduly light for their gestational age. Details of the neurological and ophthalmological defects are given, and the predictive significance of neonatal variables is analyzed.