295 resultados para LANDAU-LEVELS


Relevância:

20.00% 20.00%

Publicador:

Resumo:

Energy levels for transitions among the lowest 24 fine- structure levels belonging to the 1s(2)nl(n greater than or equal to 5) configurations of Li-like Ar XVI and Fe XXIV have been calculated using the fully relativistic GRASP code. Oscillator strengths, radiative rates and line strengths have also been generated among these levels for the four types of transitions: electric dipole (E1), magnetic dipole (M1), electric quadrupole (E2) and magnetic quadrupole (M2). Comparisons are made for the electric dipole transitions with other available results, and the accuracy of the present data is assessed.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

A large-scale configuration interaction (Cl) calculation using Program CIV3 of Hibbert is performed for the lowest 62 fine- structure levels of the singly charged chlorine ion. Our calculated energy levels agree very well with most of the NIST results and confirm the identification of the lowest P-1(o) as actually 3s(2)3p(3)(D-2(o))3d P-1(o) rather than the generally employed 3s3p(5) P-1(o) in measurements and calculations. Discrepancies in the energy positions of some symmetries are found and discussed. Some large oscillator strengths for allowed and intercombination transitions in both length and velocity gauges are presented. Their close agreement gives credence to the accuracy of our CI wavefunctions.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Pregnancy is proposed to be a Th2 phenomenon, where Th2 cytokines inhibit Th1 responses to improve fetal survival. The importance of interleukin-10 (IL-10), an immunomodulatory cytokine produced by Th2 cells, in the maintenance of normal pregnancy is becoming increasingly apparent. In a longitudinal case-control study, the physiological effect of pregnancy on plasma IL-10 was investigated. The plasma concentration of IL-10 was determined using an ELISA technique in 99 pregnant women sampled at 12, 20 and 35 weeks of gestation, 38 non-pregnant control subjects sampled in parallel and in a subgroup of women sampled at 3 days post-partum (n, pregnant 21, non-pregnant 21). Plasma IL-10 was significantly higher in pregnant women at 12, 20 and 35 weeks of gestation (p

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Objective: To investigate soluble P-selectin (sP-selectin) levels and platelet parameters in normal pregnant women compared with non-pregnant control subjects. Design: A longitudinal case-control study. Setting: Obstetric outpatient clinic in the Jubilee Maternity Hospital, Belfast. Population: One hundred and twenty normal pregnant women and 41 non-pregnant age matched control subjects. Main outcome measures Plasma sP-selectin as a measure of platelet activation in normal pregnancy. Methods: The plasma concentration of sP-selectin in pregnant women sampled at 12, 20 and 35 weeks of gestation, and, in a subgroup at 3 days post-partum, and non-pregnant controls sampled in parallel, was determined using a commercial quantitative sandwich immunoassay kit. Platelet parameters on each blood sample were also recorded using a SYSMEX SE 9500 analyser. Main outcome measures: Plasma sP-selectin as a measure of platelet activation in normal pregnancy. Results: Soluble P-selectin was significantly higher in pregnant women than in non-pregnant control subjects at 20 and 35 weeks of gestation, (p

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Background. Post-renal transplant anaemia is a potentially reversible cardiovascular risk factor. Graft function, immunosuppressive agents and inhibition of the renin-angiotensin system have been implicated in its aetiology. The evaluation of erythropoietin (EPO) levels may contribute to understanding the relative contributions of these factors. Methods. Two-hundred and seven renal transplant recipients attending the Belfast City Hospital were studied. Clinical and laboratory data were extracted from the medical records and laboratory systems. Results. Of the 207 patients (126 male), 47 (22.7%) were found to be anaemic (males, haemoglobin (Hb) <12 g/dl, females Hb <11g/dl). The anaemic group had a significantly higher mean serum creatinine level (162.8 µmol/l vs 131.0 µmol/l, P <0.001) and lower mean estimated glomerular filtration rate (eGFR) (41.5 ml/min vs 54.9 ml/min, P <0.001) than the non-anaemic group. Individual immunosuppressive regimens were comparable between those with and those without anaemia. Angiotensin converting enzyme inhibitor (ACE-I) or angiotensin receptor blocker (ARB) administration was not more prevalent in those with anaemia compared with those without (36.2 vs 38.8, P = 0.88). There was a significant inverse correlation between Hb levels and serum EPO levels (R = -0.29, P <0.001), but not between EPO levels and eGFR (R = 0.02, P = 0.74). Higher EPO levels were predictive of anaemia, independent of eGFR in multivariate analysis. Conclusion. Anaemia is common in post-renal transplant patients. The levels of renal function and serum EPO and not immunosuppressive regimens or ACE-I/ARB use, are strong and independent predictors of anaemia. © The Author [2007]. Published by Oxford University Press on behalf of ERA-EDTA. All rights reserved.