44 resultados para ISO 14000


Relevância:

10.00% 10.00%

Publicador:

Resumo:

The initial composition of acrylic bone cement along with the mixing and delivery technique used can influence its final properties and therefore its clinical success in vivo. The polymerisation of acrylic bone cement is complex with a number of processes happening simultaneously. Acrylic bone cement mixing and delivery systems have undergone several design changes in their advancement, although the cement constituents themselves have remained unchanged since they were first used. This study was conducted to determine the factors that had the greatest effect on the final properties of acrylic bone cement using a pre-filled bone cement mixing and delivery system. A design of experiments (DoE) approach was used to determine the impact of the factors associated with this mixing and delivery method on the final properties of the cement produced. The DoE illustrated that all factors present within this study had a significant impact on the final properties of the cement. An optimum cement composition was hypothesised and tested. This optimum recipe produced cement with final mechanical and thermal properties within the clinical guidelines and stated by ISO 5833 (International Standard Organisation (ISO), International standard 5833: implants for surgery—acrylic resin cements, 2002), however the low setting times observed would not be clinically viable and could result in complications during the surgical technique. As a result further development would be required to improve the setting time of the cement in order for it to be deemed suitable for use in total joint replacement surgery.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Hip replacement surgery is amongst the most common orthopaedic operations performed in the UK. Aseptic loosening is responsible for 40% of hip revision procedures. Aseptic loosening is a result of cement mantle fatigue. The aim of the current study is to analyse the effect of nanoscale Graphene Oxide (GO) on the mechanical properties of orthopaedic bone cement. Study Design A experimental thermal and mechanical analysis was conducted in a laboratory set up conforming to international standards for bone cement testing according to ISO 5583. Testing was performed on control cement samples of Colacryl bone cement, and additional samples reinforced with variable wt% of Graphene Oxide containing composites – 0.1%, 0.25%, 0.5% and 1.0% GO loading. Pilot Data Porosity demonstrated a linear relationship with increasing wt% loading compared to control (p<0.001). Thermal characterisation demonstrated maximal temperature during polymerization, and generated exotherm were inversely proportional to w%t loading (p<0.05) Fatigue strength performed on the control and 0.1 and 0.25%wt loadings of GO demonstrate increased average cycles to failure compared to control specimens. A right shift of the Weibull curve was demonstrated for both wt% available currently. Logistic regression analysis for failure demonstrated significant increases in number of cycles to failure for both specimens compared to a control (p<0.001). Forward Plan Early results convey positive benefits at low wt% loadings of GO containing bone cement. Study completion and further analysis is required in order to elude to the optimum w%t of GO which conveys the greatest mechanical advantage.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

A new technological approach in the analysis and forensic interpretation of Total Hydrocarbons in soils and waters using 2D Gas Chromatography method (GC-GC) was developed alongside environmental forensic and the assessment models to provide better customer products for the environmental industry.
The objective was to develop an analytical methodology for TPH CWG. Raw data from this method is then to be evaluated for forensic interpretation and risk assessment modelling. Access will be made available to the expertise in methods of forensic tracing contaminant sources, transport modelling, human health risk modelling and detailed quantitative risk assessment.
The quantification of internal standards was key to the development of this method. As the laboratory does not test for TPH in 1D, it was requested during INAB ISO 17025 audit to individually map out where each compound falls chromatographically in the 2D. This was done through comparing carbon equivalent numbers to the n-alkane carbons. This proved e.g. 2-methylnaphthalene has 11 carbons in its structure; its carbon equivalent is 12.84 , the result of which falls within the band of Aromatic eC12-eC16 as opposed to expected eC10-eC12. This was carried out for all 16 PAH (polyaromatic hydrocarbons) and BTEX (benzene, toluene, ethylbenzene and o, m and p-xylenes). The n-alkanes were also assigned to their corresponding aliphatic bands e.g. nC8 would be expected to be in nC8-nC10.
The method was validated through a designated systematic experimental protocol and was challenged with spikes of known concentration of hydrocarbon parameters such as recoveries, precision, bias and linearity. The method was verified by testing a certified reference material which was used as a proficiency round of testing for numerous laboratories.
It is hoped that the method will be used in conjunction with the analysis through Bonn Agreement with their OSINet group. This is a panel of experts and laboratories (including CLS) who forensically identify oil spill contamination from a water source.
This method can prove itself to be a robust method and benefit the industry for contaminated land and water but the method needs to be seen as separate from the regular 1D chromatography. It will help identify contaminants and assist consultants, regulators, clients and scientists valuable information not seen in 1D

Relevância:

10.00% 10.00%

Publicador:

Resumo:

The use of an acid violet 7 (AV7) smart ink to assess the activity of photocatalytic paint is demonstrated. A linear correlation is established between the change in oxidized dye concentration, as measured by diffuse reflectance, and the change in the green component of the RGB color values, obtained using a portable hand-held scanner, suggesting that such tests can be monitored easily using an inexpensive piece of hand-held office equipment, as opposed to an expensive lab-based instrument, such as a diffuse reflectance UV/vis spectrophotometer. The bleaching of the AV7 follows first order kinetics, at a rate that is linearly dependent upon the UVA irradiance (0.30–3.26 mW cm–2). A comparison of relative rate of bleaching of the AV7 ink with the relative rate of removal of NOx, as determined using the ISO test (ISO 22197-1:2007), established a linear relationship between the two sets of results and the relevance of this correlation is discussed briefly.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Three photocatalyst inks based on the redox dyes, Resazurin (Rz), Basic Blue 66 (BB66) and Acid Violet 7 (AV7), are used to assess the photocatalytic activities of a variety of different materials, such as commercial paint, tiles and glass and laboratory made samples of sol–gel coated glass and paint, which collectively exhibit a wide range of activities that cannot currently be probed by any one of the existing ISO tests. Unlike the ISO tests, the ink tests are fast (typically <10 min), simple to employ and inexpensive. Previous work indicates that the Rz ink test at least correlates linearly with other photocatalytic tests such as the photomineralisation of stearic acid. The average time to bleach 90% of the key RGB colour component of the ink, red for Rz and BB66 inks and green for AV7 ink, is determined, ttb(90), for eight samples of each of the different materials tested. Five laboratories conducted the tests and the results revealed an average repeatability and reproducibility of: ca. 11% and ca 21%, respectively, which compare well with those reported for the current ISO tests. Additional work on commercial self-cleaning glass using an Rz ink showed that the change in the red component of the RGB image of the ink correlated linearly with that of the change of absorbance at 608 nm, as measured using UV/vis spectroscopy, and the change in the a* component of the Lab colour analysis of the ink, as measured using diffuse reflectance spectroscopy. As a consequence, all three methods generate the same ttb(90). The advantages of the RGB digital image analysis method are discussed briefly.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

We present a rigorous methodology and new metrics for fair comparison of server and microserver platforms. Deploying our methodology and metrics, we compare a microserver with ARM cores against two servers with ×86 cores running the same real-time financial analytics workload. We define workload-specific but platform-independent performance metrics for platform comparison, targeting both datacenter operators and end users. Our methodology establishes that a server based on the Xeon Phi co-processor delivers the highest performance and energy efficiency. However, by scaling out energy-efficient microservers, we achieve competitive or better energy efficiency than a power-equivalent server with two Sandy Bridge sockets, despite the microserver's slower cores. Using a new iso-QoS metric, we find that the ARM microserver scales enough to meet market throughput demand, that is, a 100% QoS in terms of timely option pricing, with as little as 55% of the energy consumed by the Sandy Bridge server.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

The invention relates to a process for dissolving metals (e.g., Al, Cu, Fe, Cr, Sb, Ti, and W) in perhalide contg. ionic liqs. having the formula (I), and to the extn. of metals from mineral ores; the remediation of materials contaminated with heavy, toxic, or radioactive metals; and to the removal of heavy and toxic metals from hydrocarbon streams. In the formula (I), [X] comprises at least one perhalide anion selected from [I3]-, [BrI2]-, [Br2I]-, [ClI2]-, [ClBr2]-, [BrCl2]-, or [ICl2]-, [ClI3]-. The (Cat+) is a cationic species selected from: ammonium, azaannulenium, azathiazolium, benzimidazolium, benzofuranium, benzotriazolium, borolium, cinnolinium, diazabicyclodecenium, diazabicyclononenium, diazabicyclo- undecenium, dithiazolium, furanium, guanidinium, imidazolium, indazolium, indolinium, indolium, morpholinium, oxaborolium, oxaphospholium, oxazinium, oxazolium, iso-oxazolium, oxathiazolium, pentazolium, phospholium, phosphonium, phthalazinium, piperazinium, piperidinium, pyranium, pyrazinium, pyrazolium, pyridazinium, pyridinium, pyrimidinium, pyrrolidinium, pyrrolium, quinazolinium, quinolinium, isoquinolinium, quinoxalinium, selenozolium, sulfonium, tetrazolium, iso-thiadiazolium, thiazinium, thiazolium, thiophenium, thiuronium, triazadecenium, triazinium, triazolium, iso-triazolium, and uronium. [on SciFinder(R)]

Relevância:

10.00% 10.00%

Publicador:

Resumo:

We report a case of acute lymphoblastic leukaemia relapsing after allogeneic bone marrow transplantation in which the polymerase chain reaction (PCR) was used to assess chimeric status. This technique demonstrated the progressive reappearance of host cells prior to clinical relapse. The relapse was of host cell origin as shown by the presence of female (recipient) metaphases containing an abnormal chromosomal marker (iso 9q) which had also been present at initial diagnosis. The emergence of host cells in this case, detected only by PCR techniques but not by cytogenetic methods, appeared to herald overt relapse. PCR analysis provides a sensitive tool for detecting a progressive rise in host cell numbers which may predict clinical relapse.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

A preliminary investigation of electrocatalytic oxidation activity ofbutanol isomers has been carried out to study their potential asfuels for direct alcohol fuel cells. The electrochemical study wascarried out on Pt and Pd electrodes using a three electrode cell setup in alkaline media. The primary alcohol isomers of butanol wereobserved to behave similarly in their electrochemical reactionswhereas 2-butanol showed completely different oxidation featureson both catalysts. For example, no poisoning effects were observedfor 2- butanol unlike for the primary butanol isomers. In contrast,tert-butanol did not show any oxidation reaction on Pt and Pdelectrodes. Furthermore, Pd was not active at all in acidic mediafor butanol oxidation. The reactivity of butanol isomers were foundto be in the order n-butanol>iso-butanol>2-butanol>tert-butanolbased on the oxidation current density values.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

A periodic monitoring of the pavement condition facilitates a cost-effective distribution of the resources available for maintenance of the road infrastructure network. The task can be accurately carried out using profilometers, but such an approach is generally expensive. This paper presents a method to collect information on the road profile via accelerometers mounted in a fleet of non-specialist vehicles, such as police cars, that are in use for other purposes. It proposes an optimisation algorithm, based on Cross Entropy theory, to predict road irregularities. The Cross Entropy algorithm estimates the height of the road irregularities from vehicle accelerations at each point in time. To test the algorithm, the crossing of a half-car roll model is simulated over a range of road profiles to obtain accelerations of the vehicle sprung and unsprung masses. Then, the simulated vehicle accelerations are used as input in an iterative procedure that searches for the best solution to the inverse problem of finding road irregularities. In each iteration, a sample of road profiles is generated and an objective function defined as the sum of squares of differences between the ‘measured’ and predicted accelerations is minimized until convergence is reached. The reconstructed profile is classified according to ISO and IRI recommendations and compared to its original class. Results demonstrate that the approach is feasible and that a good estimate of the short-wavelength features of the road profile can be detected, despite the variability between the vehicles used to collect the data.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

This paper presents the results of a full-scale site fire test performed on a cold-formed steel portal frame building with semi-rigid joints. The purpose of the study is to establish a performance-based approach for the design of such structures in fire boundary conditions. In the full-scale site fire test, the building collapsed asymmetrically at a temperature of 714°C. A non-linear elasto-plastic finite-element shell model is described and is validated against the results of the full-scale test. A parametric study is presented that highlights the importance of in-plane restraint from the side rails in preventing an outwards sway failure for both a single portal and full building geometry model. The study also demonstrates that the semi-rigidity of the joints should be taken into account in the design. The single portal and full building geometry models display a close match to site test results with failure at 682°C and 704°C, respectively. A design case is described in accordance with Steel Construction Institute design recommendations. The validated single portal model is tested with pinned bases, columns protected, realistic loading and rafters subject to symmetric uniform heating in accordance with the ISO 834 standard fire curve; failure occurs at 703°C.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

AIM: In view of the increased rates of pre-eclampsia observed in diabetic pregnancy and the lack of ex vivo data on placental biomarkers of oxidative stress in T1 diabetic pregnancy, the aim of the current investigation was to examine placental antioxidant enzyme status and lipid peroxidation in pregnant women with type 1 diabetes. A further objective of the study was to investigate the putative impact of vitamin C and E supplementation on antioxidant enzyme activity and lipid peroxidation in type 1 diabetic placentae.

METHODS: The current study measured levels of antioxidant enzyme [glutathione peroxidase (Gpx), glutathione reductase (Gred), superoxide dismutase (SOD) and catalase] activity and degree of lipid peroxidation (aqueous phase hydroperoxides and 8-iso-prostaglandin F2α) in matched central and peripheral samples from placentae of DAPIT (n=57) participants. Levels of vitamin C and E were assessed in placentae and cord blood.

RESULTS: Peripheral placentae demonstrated significant increases in Gpx and Gred activities in pre-eclamptic in comparison to non-pre-eclamptic women. Vitamin C and E supplementation had no significant effect on cord blood or placental levels of these vitamins, nor on placental antioxidant enzyme activity or degree of lipid peroxidation in comparison to placebo-supplementation.

CONCLUSION: The finding that maternal supplementation with vitamin C/E does not augment cord or placental levels of these vitamins is likely to explain the lack of effect of such supplementation on placental indices including antioxidant enzymes or markers of lipid peroxidation.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Immunohistochemistry (IHC) is a widely available and highly utilised tool in diagnostic histopathology and is used to guide treatment options as well as provide prognostic information. IHC is subjected to qualitative and subjective assessment, which has been criticised for a lack of stringency, while PCR-based molecular diagnostic validations by comparison are regarded as very rigorous. It is essential that IHC tests are validated through evidence-based procedures. With the move to ISO15189 (2012), not just of the accuracy, specificity and reproducibility of each test need to be determined and managed, but also the degree of uncertainty and the delivery of such tests. The recent update to ISO 15189 (2012) states that it is appropriate to consider the potential uncertainty of measurement of the value obtained in the laboratory and how that may impact on prognostic or predictive thresholds. In order to highlight the problems surrounding IHC validity, we reviewed the measurement of Ki67and p53 in the literature. Both of these biomarkers have been incorporated into clinical care by pathology laboratories worldwide. The variation seen appears excessive even when measuring centrally stained slides from the same cases. We therefore propose in this paper to establish the basis on which IHC laboratories can bring the same level of robust validation seen in the molecular pathology laboratories and the principles applied to all routine IHC tests.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

This study rigorously evaluated a previously developed immunobead array method to simultaneously detect three important foodborne pathogens, Campylobacter jejuni, Listeria monocytogenes, and Salmonella spp., for its actual application in routine food testing. Due to the limitation of the detection limit of the developed method, an enrichment step was included in this study by using Campylobacter Enrichment Broth for C. jejuni and Universal Pre-enrichment Broth for L. monocytogenes and Salmonella spp.. The findings show that the immunobead array method was capable of detecting as low as 1 CFU of the pathogens spiked in the culture media after being cultured for 24 hours for all three pathogens. The immunobead array method was further evaluated for its pathogen detection capabilities in ready-to-eat (RTE) and ready-to-cook (RTC) chicken samples and proven to be able to detect as low as 1 CFU of the pathogens spiked in the food samples after being cultured for 24 hours in the case of Salmonella spp., and L. monocytogenes and 48 hours in the case of C. jejuni. The method was subsequently validated with three types of chicken products (RTE, n=30; RTC, n=20; raw chicken, n=20) and was found to give the same results as the conventional plating method. Our findings demonstrated that the previously developed immunobead array method could be used for actual food testing with minimal enrichment period of only 52 hours, whereas the conventional ISO protocols for the same pathogens take 90-144 hours. The immunobead array was therefore an inexpensive, rapid and simple method for the food testing.