42 resultados para Hand weaving


Relevância:

20.00% 20.00%

Publicador:

Relevância:

20.00% 20.00%

Publicador:

Resumo:

This paper presents a novel hand-held instrument capable of real-time in situ detection and identification of heavy metals. The proposed system provides the facilities found in a traditional lab-based instrument in a hand held a design. In contrast to existing commercial systems, it can stand alone without the need of an associated computer. The electrochemical instrument uses anodic stripping voltammetry which is a precise and sensitive analytical method with excellent limits of detection. The sensors comprise disposable screen-printed (solid working) electrodes rather than the more common hanging mercury drop electrodes. The system is reliable, easy to use, safe, avoids expensive and time-consuming procedures and may be used in a variety of situations to help in the fields of environmental assessment and control.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Objectives: The purpose of this investigation was to determine for dispensed multiples (1 through 4) of powder (P) and liquid (L) in hand-mixed dental cement whether: (1) the mean (P/L) ratio (m/m) and (2) the maximum difference in (P/L) ratio is dependent on the number of multiples dispensed. The Null hypotheses were: (a) mean (P/L) ratio is independent of the number of multiples dispensed and (b) maximum difference in (P/L) ratio is independent of the number of multiples dispensed.
Methods: The materials investigated are listed in the Table. The masses of dispensed aliquots of powder and liquid were measured by a single operator (n=10, for multiples 1 through 4) on a 4-place analytical balance. All measurements were made independently and all possible (P/L) ratios calculated for each sample. The effect of multiple dispensations on (P/L) ratios and maximum (P/L) differences was by one-way ANOVA and linear regression, respectively, with the Tukey post-hoc correction for multiple comparisons.MULTIPLE DISPENSEDDISPENSED MU(x1)(x2)(x3)(x4)Zinc phosphateHeraeus12.271(0.691)a13.051(1.269)b13.215(0.824)b13.118(1.149)bFuji IXGC4.209(0.373)a4.085(0.275)b4.095(0.226)b4.095(0.217)bIRMDentsply7.933(0.767)a7.430(0.451)b7.977(0.729)a8.186(0.929)aKetac-Cem3M Espe9.6206(0.613)a9.714(0.523)a9.298(0.314)b9.321(0.292)bMean (SD) powder/liquid ratio (m/m). Superscript letters represent significances (α = 0.05) within each material
Results: Mean (SD) (P/L) ratios are presented in the Table. Null hypothesis (a) is rejected: either (x1) or (x2) dispensation yields a different (P/L) ratio to (x3) or (x4) (p < 0.05). Null hypothesis (b) is rejected: a negative correlation is observed in max (P/L) ratio difference with dispensed multiple for Ketac Cem (p = 0.029).
Conclusion: For hand-mixed dental cements: (1) more consistent (P/L) ratios may be observed with multiple dispensations of powder & liquid; (2) maximum differences in (P/L) ratio may be negatively correlated with dispensation multiple in some materials.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Hands can be a vector for transmitting pathogenic microorganisms to foodstuffs and drinks, and to the mouths of susceptible hosts. Hand washing is the primary barrier to prevent transmission of enteric pathogens via cross contamination from infected persons. Conventional hand washing involves the use of warm water, soap and friction to remove dirt and microorganisms. Over recent years there has been an increasing availability of hand sanitizing products for use when water and soap are unavailable. The aim of this systematic review was to collate scientific information on the efficacy of hand sanitizers compared to hand washing with soap and water for the removal of foodborne pathogens from the hands of food handlers. An extensive literature search was carried out using three electronic databases - Web of Science, Scopus and PubMed. Twenty-eight scientific publications were ultimately included in the review. Analysis of the literature showed various limitations in the scientific information due to the absence of a standardized protocol to evaluate efficacy of hand products, and variation in experimental conditions applied in different studies. Despite the existence of conflicting results, scientific evidence seems to support the historical scepticism about the use of water-less hand sanitizers in food preparation settings. Water and soap appear to achieve greater removal of soil and microorganisms than water-less products from hands. None of the hand sanitizers tested in the literature seemed to achieve complete inactivation or removal of all foodborne pathogens tested, and the presence of food debris significantly affected inactivation rates of hand products.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The process of learning to play a musical instrument necessarily alters the functional organisation of the cortical motor areas that are involved in generating the required movements. In the case of the harp, the demands placed on the motor system are quite specific. During performance, all digits with the sole exception of the little finger are used to pluck the strings. With a view to elucidating the impact of having acquired this highly specialized musical skill on the characteristics of corticospinal projections to the intrinsic hand muscles, focal transcranial magnetic stimulation (TMS) was used to elicit motor evoked potentials (MEPs) in three muscles (of the left hand): abductor pollicis brevis (APB); first dorsal interosseous (FDI); and abductor digiti minimi (ADM) in seven harpists. Seven non-musicians served as controls. With respect to the FDI muscle–which moves the index finger, the harpists exhibited reliably larger MEP amplitudes than those in the control group. In contrast, MEPs evoked in the ADM muscle–which activates the little finger, were smaller in the harpists than in the non-musicians. The locations on the scalp over which magnetic stimulation elicited discriminable responses in ADM also differed between the harpists and the non-musicians. This specific pattern of variation in the excitability of corticospinal projections to these intrinsic hand muscles exhibited by harpists is in accordance with the idiosyncratic functional demands that are imposed in playing this instrument.