59 resultados para HE-NE LASER


Relevância:

30.00% 30.00%

Publicador:

Resumo:

Aluminium thin films were deposited by a laser ablation technique from solid cylindrical targets rotated on a lead screw. Both smooth-surfaced targets and targets with screw threads cut into the area to he irradiated were used. The targets were irradiated with a focused circular spot size of 2.5 mm in diameter, at a power density equal to 5.4 +/- 0.2 x 10(8) W cm(-2). The polar distribution of the ablated atomic material was found to vary as a function of the target screw thread pitch, with the exponent n, in the polar distribution f(theta) = cos(n) theta, varying from 13.5 +/- 1.3 for no pitch to a minimum of 5 +/- 0.7 for a screw thread pitch of 0.2 mm. The use of such novel target geometries forms a possible basis for increasing thickness uniformity during the pulsed laser deposition of thin films.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Saturation of a low pump energy x-ray laser utilizing a transient inversion mechanism on the 3p-3s transition at 32.63 nm in Ne-like Ti has been demonstrated. A close to saturation amplification was simultaneously achieved for the 3d-3p, J=1-->1 transition at 30.15 nm. Small signal effective transient gain coefficients of g similar to 46 and similar to 35 cm(-1) and gain-length products of 16.7 and 16.9 for these lines were obtained. Experiments demonstrate that it is possible to achieve saturated laser action in a transient regime with Ne-like Ti for a pump energy as low as similar to 5 J.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

The transient-excitation pumping scheme, in which a picosecond duration pulse rapidly heats the plasma preformed by a low-intensity nanosecond pulse, was used to pump the Ne-like germanium, J = 0-1 transition at 19.6 nm. A small-signal gain coefficient of 30 cm(-1) was measured for targets less than or equal to 5 mm long. (C) 1998 Optical Society of America.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Multipulse irradiation with 100 ps pulses of stripe Germanium targets is shown to enhance by up to several orders-of-magnitude the output of Ne-like Ge lasing on the J = 0-1 line at 196 Angstrom compared to single pulse pumping. Various pre-pulse and multipulse configurations have been experimentally investigated for irradiances of approximate to 4 x 10(13) W/cm(2) with a 1.06 mu m wavelength pumping laser. The ionisation balance measured by a KeV crystal spectrometer (KAP crystal) has been found to not affect the X-ray laser output. Good agreement between the experimental results and a fluid code incorporating atomic physics, gain and X-ray beam ray tracing is obtained. The code results show that the enhanced X-ray laser output is produced by multipulse irradiation reducing the electron density gradients in the gain region and simultaneously increasing the gain region spatial size. These changes reduce the effect of refraction on the X-ray laser beam propagation.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

A comparison is presented of the temporally resolved resonance-line emission from the Ne-like Ge XUV laser (pumped with nanosecond pulses) with the predictions for the same emission from the hydro-atomic code EHYBRID. The specific lines chosen were the two 3s-2p Ne-like lines at 10.01 and 9.762 Angstrom, and the 3s-2p F-like group of lines in the 9.4-9.6 Angstrom region. Modification of the code to include 112 excited levels of the F-like ion facilitated a direct comparison between experiment and model of (i) the temporal variation of the emissions and (ii) the variation of the peak intensity ratios of the F-like to Ne-like emissions with irradiance on target.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Through the use of time-integrated space-resolved keV spectroscopy, we investigate line plasmas showing gain in Ne-like nickel, copper, and zinc for irradiation using the prepulse technique. The experiments were conducted at 1.06 mu m with the prepulse to main pulse intensity contrast ranging from 10(-6) to 10(-2). The effect of the prepulses on the plasma conditions is inferred through spectroscopic line ratio diagnostics for the electron temperature, the Ne-like ground-state density, and the lateral size of the Ne-like region. It is observed that neither the value of the electronic temperature nor its spatially resolved profile along the linear focus axis varies significantly with the prepulse level, contrary to the lateral width and the density of the Ne-like region in the plasma, which are seen to increase. These results explain, at least in part, why prepulsed x-ray lasers show such high gain and brightness.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Recombining plasmas produced by picosecond laser pulses are characterized by measuring ratio of intensities of resonance lines of H- and He-like ions in the plasmas. It is found that the rapidly recombining plasmas produced by picosecond laser pulses are suitable for high-gain operation.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Through the use of time-integrated space-resolved keV spectroscopy, we characterize line plasmas showing gain in Ne-like Zn with prepulsed irradiation to explain the enhanced performances of x-ray lasers using the prepulse technique. It is observed that the value of the electron temperature does not vary significantly with prepulse level, nor does its spatially resolved profile along the line. The lateral width and density of the Ne-like region in the plasma are seen to increase with the prepulse level. (C) 1995 Optical Society of America

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Lasing properties of a collisional-excitation Ne-like Ge soft-x-ray laser have been studied with exploding-foil, single-slab, and double-slab targets under identical pumping conditions. Experimental results for the angular intensity distributions and the temporal variations of the lasing intensities are examined with a hydrodynamic code and ray-trace calculations. The observed angular distribution are well reproduced by these analyses, and it is found that the effective gain regions are located on the high-density side of the expected gain regions. It is shown that the observed lasing intensity of the J = 0 to J = 1 line is strongly correlated with the temporal change of the calculated electron temperature for both the slab and the exploding-foil targets.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Coupling of a soft X-ray laser beam with a relaying concave mirror in a sequentially pumped amplifier geometry using the Ne-like Ge system has been studied experimentally. Preliminary observations indicate an increase in the spatial coherence of the amplified relayed beam. In addition, near-field imaging of one of the amplifier plasmas shows a double-lobed intensity pattern of the emergent beam indicating refractive guiding of the amplified beam with components both normal and tangential to the target surface.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

The complex problem of a collisionally pumped Ne-like geranium laser is examined through several detailed models. The central model is EHYBRID; a 1 1/2D fluid code which self consistently treats the plasma expansion with the atomic physics of the Ne-like ion for 124 excited levels through a collisional radiative treatment. The output of EHYBRID is used as data for ray-tracing and saturation codes which generate experimental observables. A detailed description of the models is given.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

An imaging microscope, comprising a Schwarzchild condenser and zone plate optical arrangement, has been established on the Vulcan Nd-glass laser system at the Rutherford Appleton Laboratory (RAL). Images of simple test structures have been taken in X-ray transmission using doublet X-ray laser radiation at 23.2 nm and 23.6 nm from collisionally pumped Ne-like germanium. Image resolution of about 0.15 mum has been measured.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

An imaging microscope, comprising a Schwarzchild condenser and a zone-plate optical arrangement, has been established on the Vulcan Nd:glass laser system at the Rutherford Appleton Laboratory. Magnified images of simple test structures have been taken in x-ray transmission in a single subnanosecond laser shot by using doublet x-ray laser radiation at 23.2 and 23.6 nm from collisionally pumped Ne-like germanium. Image resolutions of approximately 0.15 mum have been measured. The results are a proof of principle and demonstrate that images of potentially suboptical resolution and of specimen regions that are destroyed on passage of the x-ray beam can be taken successfully using the Vulcan x-ray laser.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Characteristics of the 3p-3s amplified spontaneous emission from Ne-like Ge plasma columns, generated by ablation from massive targets, have been studied in detail. In particular, the gain coefficients of the J = 2-1 lines at 23.2 and 23.6 nm have been measured as a function of incident intensity for a 1.05-mu-m wavelength pump laser beam. For 100-mu-m wide stripe targets and a fixed energy pump laser the maximum gain length product is achieved at an irradiance of